This study proposes a new method for detecting and classifying faults in distribution lines. The physical principle of classification is based on time-domain pulse reflectometry (TDR). These high-frequency pulses are injected into the line, propagate through all of its bifurcations, and are reflected back to the injection point. According to the impedances encountered along the way, these signals carry information regarding the state of the line. In the present work, an initial signal database was obtained using the TDR technique, simulating a real distribution line using (PSCAD™). By transforming these signals into images and reducing their dimensionality, these signals are processed using convolutional neural networks (CNN). In particular, in this study, contrastive learning in Siamese networks was used for the classification of different types of faults (ToF). In addition, to avoid the problem of overfitting owing to the scarcity of examples, generative adversarial neural networks (GAN) have been used to synthesise new examples, enlarging the initial database. The combination of Siamese neural networks and GAN allows the classification of this type of signal using only synthesised examples to train and validate and only the original examples to test the network. This solves the problem of the lack of original examples in this type of signal of natural phenomena which are difficult to obtain and simulate.

3 February 2011 in Journal of Real-Time Image Processing
Verified
Journal Article
Closed access
PDF file
MLMiguel Angel Montañés Laborda
Miguel Angel Montañés Laborda
EMEnrique F. Torres Moreno
Enrique F. Torres Moreno
JRJesus Martinez-del Rincon
Jesus Martinez-del Rincon
JJJosé Elías Herrero Jaraba
José Elías Herrero Jaraba

6 March 2023 in IEEE Access
Verified
Journal Article
Open access
JFJavier Granado Fornás
Javier Granado Fornás
JJJosé Elías Herrero Jaraba
José Elías Herrero Jaraba
HBHans Bludszuweit
Hans Bludszuweit
DCDavid Cervero
David Cervero
AEAndrés Llombart Estopiñán
Andrés Llombart Estopiñán
Today, the classification and location of faults in electrical networks remains a topic of great interest. Faults are a major issue, mainly due to the time spent to detect, locate, and repair the cause of the fault. To reduce time and associated costs, automatic fault classification and location is gaining great interest. State-of-the-art techniques to classify and locate faults are mainly based on line-impedance measurements or the detection of the traveling wave produced by the event caused by the fault itself. In contrast, this paper describes the methodology for creating a database and a model for a complex distribution network. Both objectives are covered under the paradigm of the time-domain pulse reflectometry (TDR) principle. By using this technique, large distances can be monitored on a line with a single device. Thus, in this way a database is shared and created from the results of simulations of a real and complex distribution network modeled in the PSCADTM software, which have been validated with measurements from an experimental test setup. Experimental validations have shown that the combination of the TDR technique with the modeling of a real network (including the real injector and the network coupling filter from the prototype) provides high-quality signals that are very similar and reliable to the real ones. In this sense, it is intended firstly that this model and its corresponding data will serve as a basis for further processing by any of the existing state-of-the-art techniques. And secondly, to become a valid alternative to the already well-known Test Feeders but adapted to work groups not used to the electrical world but to the environment of pure data processing.

18 September 2023 in IEEE Access
Verified
Journal Article
Open access
JFJavier Granado Fornás
Javier Granado Fornás
JJJosé Elías Herrero Jaraba
José Elías Herrero Jaraba
AEAndrés Llombart Estopiñán
Andrés Llombart Estopiñán
Fault localization in distribution grids represents a crucial aspect in achieving the concept of smart grids within electrical networks. Despite the existence of various approaches to address this issue, it remains an open and challenging topic in real situations and, therefore, complex grids. One of the main challenges stems from the scarcity of labelled real-world examples is due to the inherent chaotic nature of faults (short circuits between a phase and ground). Obtaining sufficient fault examples for neural network training purposes becomes extremely difficult. Efforts have been made to simulate fault signals and apply data augmentation techniques. However, for fault location specifically, classical augmentation techniques are not applicable due to the unique nature of the fault signals. In this paper, we propose a novel approach to address the problem of extracting fault location information from TDR (Time Domain Reflectometry) signals. This kind of signals, involve injecting pulses into the grid and record these pulses as a bounced signal due to the different impedance changes of the grid. Our approach relies on employing a Transformer for anomaly detection. This Transformer-based Siamese network architecture (abbreviated by TransSiamese) is inspired by TranAD model. This Transformer has been modified to be trained in a Siamese way with a few examples (pre-fault signals/normal state and fault signals/abnormal state). After training phase, we can run inference mode by feeding it signals representing faulty grid states (fault signals). The Transformer attempts to predict the evolution of the signal, however, from a certain point to the end, the predicted fault signal deviates from the True signal supplied. Thanks to the intrinsic property of the Siamese network, it dampens the differences between the learned and the current signal when it comes to pre-fault; on the contrary, it enhances these differences when we are immersed in a fault signal.

5 February 2026 in Engineering Applications of Artificial Intelligence
Verified
Journal Article
Open access
JJJosé Elías Herrero Jaraba
José Elías Herrero Jaraba
ECEduardo Martínez Carrasco
Eduardo Martínez Carrasco
Aníbal Antonio Prada HurtadoAníbal Antonio Prada Hurtado
Aníbal Antonio Prada Hurtado
MVMaria Teresa Villen
Maria Teresa Villen
GGGuillermo Rios Gómez
Guillermo Rios Gómez
JPJulio David Buldain Pérez
Julio David Buldain Pérez

16 December 2009 in Journal of Mathematical Imaging and Vision
Verified
Journal Article
Closed access
PDF file
CMCarlos Medrano
Carlos Medrano
JRJesus Martinez-del Rincon
Jesus Martinez-del Rincon
Raul IgualRaul Igual