Elza Abdessater

Dr. Elza Abdessater

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Amin HosseinAmin Hossein
Amin Hossein
Elza AbdessaterElza Abdessater
Elza Abdessater
Paniz BalaliPaniz Balali
Paniz Balali
ECElliot Cosneau
Elliot Cosneau
DGDamien Gorlier
Damien Gorlier
PBPhilippe van de Borne
Philippe van de Borne
Seismocardiography (SCG), a method for measuring heart-induced chest vibrations, is gaining attention as a non-invasive, accessible, and cost-effective approach for cardiac pathologies, diagnosis, and monitoring. This study explores the integration of SCG acquired through smartphone technology by assessing the accuracy of metrics derived from smartphone recordings and their consistency when performed by patients. Therefore, we assessed smartphone-derived SCG’s reliability in computing median kinetic energy parameters per record in 220 patients with various cardiovascular conditions. The study involved three key procedures: (1) simultaneous measurements of a validated hardware device and a commercial smartphone; (2) consecutive smartphone recordings performed by both clinicians and patients; (3) patients’ self-conducted home recordings over three months. Our findings indicate a moderate-to-high reliability of smartphone-acquired SCG metrics compared to those obtained from a validated device, with intraclass correlation (ICC) > 0.77. The reliability of patient-acquired SCG metrics was high (ICC > 0.83). Within the cohort, 138 patients had smartphones that met the compatibility criteria for the study, with an observed at-home compliance rate of 41.4%. This research validates the potential of smartphone-derived SCG acquisition in providing repeatable SCG metrics in telemedicine, thus laying a foundation for future studies to enhance the precision of at-home cardiac data acquisition.

27 May 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Elza AbdessaterElza Abdessater
Elza Abdessater
Paniz BalaliPaniz Balali
Paniz Balali
JPJimmy Pawlowski
Jimmy Pawlowski
Jeremy RabineauJeremy Rabineau
Jeremy Rabineau
Cyril TordeurCyril Tordeur
Cyril Tordeur
Amin HosseinAmin Hossein
Amin Hossein
Severe aortic valve diseases (AVD) cause changes in heart sounds, making phonocardiogram (PCG) analyses challenging. This study presents a novel method for segmenting heart sounds without relying on an electrocardiogram (ECG), specifically targeting patients with severe AVD. Our algorithm enhances traditional Hidden Semi-Markov Models by incorporating signal envelope calculations and statistical tests to improve the detection of the first and second heart sounds (S1 and S2). We evaluated the method on the PhysioNet/CinC 2016 Challenge dataset and a newly acquired AVD-specific dataset. The method was tested on a total of 27,400 cardiac cycles. The proposed approach outperformed the existing methods, achieving a higher sensitivity and positive predictive value for S2, especially in the presence of severe heart murmurs. Notably, in patients with severe aortic stenosis, our proposed ECG-free method improved S2 sensitivity from 41% to 70%.

29 September 2026 in Biomedical Signal Processing and Control
Verified
Journal Article
Open access
Elza AbdessaterElza Abdessater
Elza Abdessater
Paniz BalaliPaniz Balali
Paniz Balali
YMYanis Mazzoni
Yanis Mazzoni
Jeremy RabineauJeremy Rabineau
Jeremy Rabineau
MLMohamed Lamouchi
Mohamed Lamouchi
Amin HosseinAmin Hossein
Amin Hossein