Cyril Tordeur

Mr. Cyril Tordeur

Université Libre de Bruxelles, Brussels, Brussels-Capital Region, Belgium
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Paniz BalaliPaniz Balali
Paniz Balali
Jeremy RabineauJeremy Rabineau
Jeremy Rabineau
Amin HosseinAmin Hossein
Amin Hossein
Cyril TordeurCyril Tordeur
Cyril Tordeur
ODOlivier Debeir
Olivier Debeir
PBPhilippe van de Borne
Philippe van de Borne
Ballistocardiography (BCG) and seismocardiography (SCG) are non-invasive techniques used to record the micromovements induced by cardiovascular activity at the body’s center of mass and on the chest, respectively. Since their inception, their potential for evaluating cardiovascular health has been studied. However, both BCG and SCG are impacted by respiration, leading to a periodic modulation of these signals. As a result, data processing algorithms have been developed to exclude the respiratory signals, or recording protocols have been designed to limit the respiratory bias. Reviewing the present status of the literature reveals an increasing interest in applying these techniques to extract respiratory information, as well as cardiac information. The possibility of simultaneous monitoring of respiratory and cardiovascular signals via BCG or SCG enables the monitoring of vital signs during activities that require considerable mental concentration, in extreme environments, or during sleep, where data acquisition must occur without introducing recording bias due to irritating monitoring equipment. This work aims to provide a theoretical and practical overview of cardiopulmonary interaction based on BCG and SCG signals. It covers the recent improvements in extracting respiratory signals, computing markers of the cardiorespiratory interaction with practical applications, and investigating sleep breathing disorders, as well as a comparison of different sensors used for these applications. According to the results of this review, recent studies have mainly concentrated on a few domains, especially sleep studies and heart rate variability computation. Even in those instances, the study population is not always large or diversified. Furthermore, BCG and SCG are prone to movement artifacts and are relatively subject dependent. However, the growing tendency toward artificial intelligence may help achieve a more accurate and efficient diagnosis. These encouraging results bring hope that, in the near future, such compact, lightweight BCG and SCG devices will offer a good proxy for the gold standard methods for assessing cardiorespiratory function, with the added benefit of being able to perform measurements in real-world situations, outside of the clinic, and thus decrease costs and time.

12 November 2025 in npj Microgravity
Verified
Journal Article
Open access
PDF file
Cyril TordeurCyril Tordeur
Cyril Tordeur
EAE. Abdessater
E. Abdessater
AHA. Hossein
A. Hossein
FRF. Righetti
F. Righetti
VSV. Sinitsyn
V. Sinitsyn
JRJ. Rabineau
J. Rabineau
Microgravity exposure induces cardiac deconditioning, primarily due to hypovolemia and inactivity. Animal models suggest microgravity may cause left ventricular (LV) papillary muscle atrophy, but this has not been studied in humans. This study used MRI to assess LV papillary muscle mass and LV morphology and function in nine male cosmonauts before and 6 ± 2 days after long-duration spaceflight (247 ± 90 days). Spaceflight did not affect LV volumes, ejection fraction, and strain parameters, but increased heart rate ( P < 0.001) and cardiac output ( P = 0.03). LV papillary muscle mass decreased by 14% ( P = 0.017), while LV mass tended to increase ( P = 0.083), mitral annular diameter increased ( P = 0.004) without mitral leakage, and LV sphericity increased ( P = 0.02). These findings suggest LV adapts to space with geometric changes, but microgravity-induced papillary muscle atrophy requires further study for long-term implications.

27 May 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Elza AbdessaterElza Abdessater
Elza Abdessater
Paniz BalaliPaniz Balali
Paniz Balali
JPJimmy Pawlowski
Jimmy Pawlowski
Jeremy RabineauJeremy Rabineau
Jeremy Rabineau
Cyril TordeurCyril Tordeur
Cyril Tordeur
Amin HosseinAmin Hossein
Amin Hossein
Severe aortic valve diseases (AVD) cause changes in heart sounds, making phonocardiogram (PCG) analyses challenging. This study presents a novel method for segmenting heart sounds without relying on an electrocardiogram (ECG), specifically targeting patients with severe AVD. Our algorithm enhances traditional Hidden Semi-Markov Models by incorporating signal envelope calculations and statistical tests to improve the detection of the first and second heart sounds (S1 and S2). We evaluated the method on the PhysioNet/CinC 2016 Challenge dataset and a newly acquired AVD-specific dataset. The method was tested on a total of 27,400 cardiac cycles. The proposed approach outperformed the existing methods, achieving a higher sensitivity and positive predictive value for S2, especially in the presence of severe heart murmurs. Notably, in patients with severe aortic stenosis, our proposed ECG-free method improved S2 sensitivity from 41% to 70%.