Jeremy Rabineau

Dr. Jeremy Rabineau

University of Waterloo, Waterloo, Ontario, Canada
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Paniz BalaliPaniz Balali
Paniz Balali
Jeremy RabineauJeremy Rabineau
Jeremy Rabineau
Amin HosseinAmin Hossein
Amin Hossein
Cyril TordeurCyril Tordeur
Cyril Tordeur
ODOlivier Debeir
Olivier Debeir
PBPhilippe van de Borne
Philippe van de Borne
Ballistocardiography (BCG) and seismocardiography (SCG) are non-invasive techniques used to record the micromovements induced by cardiovascular activity at the body’s center of mass and on the chest, respectively. Since their inception, their potential for evaluating cardiovascular health has been studied. However, both BCG and SCG are impacted by respiration, leading to a periodic modulation of these signals. As a result, data processing algorithms have been developed to exclude the respiratory signals, or recording protocols have been designed to limit the respiratory bias. Reviewing the present status of the literature reveals an increasing interest in applying these techniques to extract respiratory information, as well as cardiac information. The possibility of simultaneous monitoring of respiratory and cardiovascular signals via BCG or SCG enables the monitoring of vital signs during activities that require considerable mental concentration, in extreme environments, or during sleep, where data acquisition must occur without introducing recording bias due to irritating monitoring equipment. This work aims to provide a theoretical and practical overview of cardiopulmonary interaction based on BCG and SCG signals. It covers the recent improvements in extracting respiratory signals, computing markers of the cardiorespiratory interaction with practical applications, and investigating sleep breathing disorders, as well as a comparison of different sensors used for these applications. According to the results of this review, recent studies have mainly concentrated on a few domains, especially sleep studies and heart rate variability computation. Even in those instances, the study population is not always large or diversified. Furthermore, BCG and SCG are prone to movement artifacts and are relatively subject dependent. However, the growing tendency toward artificial intelligence may help achieve a more accurate and efficient diagnosis. These encouraging results bring hope that, in the near future, such compact, lightweight BCG and SCG devices will offer a good proxy for the gold standard methods for assessing cardiorespiratory function, with the added benefit of being able to perform measurements in real-world situations, outside of the clinic, and thus decrease costs and time.

15 November 2020 in ESC Heart Failure
Verified
Journal Article
Open access
PDF file
FHFabian Hoffmann
Fabian Hoffmann
Jeremy RabineauJeremy Rabineau
Jeremy Rabineau
DMDennis Mehrkens
Dennis Mehrkens
DGDarius A. Gerlach
Darius A. Gerlach
SMStefan Moestl
Stefan Moestl
JTJens Tank
Jens Tank
Aims Reduced physical activity increases the risk of heart failure; however, non‐invasive methodologies detecting subclinical changes in myocardial function are not available. We hypothesized that myocardial, left ventricular, systolic strain measurements could capture subtle abnormalities in myocardial function secondary to physical inactivity. Methods and results In the AGBRESA study, which assessed artificial gravity through centrifugation as potential countermeasure for space travel, 24 healthy persons (eight women) were submitted to 60 day strict −6° head‐down‐tilt bed rest. Participants were assigned to three groups of eight subjects: a control group, continuous artificial gravity training on a short‐arm centrifuge (30 min/day), or intermittent centrifugation (6 × 5 min/day). We assessed cardiac morphology, function, strain, and haemodynamics by cardiac magnetic resonance imaging (MRI) and echocardiography. We observed no differences between groups and, therefore, conducted a pooled analysis. Consistent with deconditioning, resting heart rate (∆8.3 ± 6.3 b.p.m., P < 0.0001), orthostatic heart rate responses (∆22.8 ± 19.7 b.p.m., P < 0.0001), and diastolic blood pressure (∆8.8 ± 6.6 mmHg, P < 0.0001) increased, whereas cardiac output (∆−0.56 ± 0.94 L/min, P = 0.0096) decreased during bed rest. Left ventricular mass index obtained by MRI did not change. Echocardiographic left ventricular, systolic, global longitudinal strain (∆1.8 ± 1.83%, P < 0.0001) decreased, whereas left ventricular, systolic, global MRI circumferential strain increased not significantly (∆−0.68 ± 1.85%, P = 0.0843). MRI values rapidly returned to baseline during recovery. Conclusion Prolonged head‐down‐tilt bed rest provokes changes in cardiac function, particularly strain measurements, that appear functional rather than mediated through cardiac remodelling. Thus, strain measurements are of limited utility in assessing influences of physical deconditioning or exercise interventions on cardiac function.

19 July 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Amin HosseinAmin Hossein
Amin Hossein
DMDaniela Corina Mirica
Daniela Corina Mirica
Jeremy RabineauJeremy Rabineau
Jeremy Rabineau
JRJosé Ignacio Del Rio
José Ignacio Del Rio
SMSofia Morra
Sofia Morra
PMPierre-François Migeotte
Pierre-François Migeotte
Non-invasive remote detection of cardiac and blood displacements is an important topic in cardiac telemedicine. Here we propose kino-cardiography (KCG), a non-invasive technique based on measurement of body vibrations produced by myocardial contraction and blood flow through the cardiac chambers and major vessels. KCG is based on ballistocardiography and measures 12 degrees-of-freedom (DOF) of body motion. We tested the hypothesis that KCG reliably assesses dobutamine-induced haemodynamic changes in healthy subjects. Using a randomized double-blinded placebo-controlled crossover study design, dobutamine and placebo were infused to 34 volunteers (25 ± 2 years, BMI 22 ± 2 kg/m², 18 females). Baseline recordings were followed by 3 sessions of increasing doses of dobutamine (5, 10, 20 μg/kg.min) or saline solution. During each session, stroke volume (SV) and cardiac output (CO) were determined by echocardiography and followed by a 90 s KCG recording. Measured linear accelerations and angular velocities were used to compute total Kinetic energy (iK) and power (Pmax). KCG sorted dobutamine infusion vs. placebo with 96.9% accuracy. Increases in SV and CO were correlated to iK (r = +0.71 and r = +0.8, respectively, p < 0.0001). Kino-cardiography, with 12-DOF, allows detecting dobutamine-induced haemodynamic changes with a high accuracy and present a major improvement over single axis ballistocardiography or seismocardiography.

8 June 2021 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
BHBenoît Haut
Benoît Haut
ANAntoine Nonclercq
Antoine Nonclercq
ABAlexandra Buess
Alexandra Buess
Jeremy RabineauJeremy Rabineau
Jeremy Rabineau
CRClément Rigaut
Clément Rigaut
BSBenjamin Sobac
Benjamin Sobac
This work presents a new mathematical model of the heat and water exchanges in the human lungs (newborn to adult). This model is based on a local description of the water and energy transports in both the lumen and the surrounding tissues, and is presented in a comprehensive, dimensionless framework with explicitly stated assumptions and a strong physiological background. The model is first used to analyze and quantify the key phenomena and dimensionless numbers governing these heat and water exchanges and then it is applied to an adult in various situations (varying atmospheric conditions, exercising…). The results highlight several interesting physiological elements. They show that the bronchial region of the lungs is able to condition the air in all the considered situations even if, sometimes, for instance when exercising, distal generations have to be involved. The model also shows that these distal generations are super-conditioners. Moreover, the results quantify the key role of the submucosal glands in mucus hydration. They also show that, during expiration, a significant cooling of the air and condensation of water occur along the respiratory tract as the vascularization of the tissues surrounding the airways is not able to maintain these tissues at body temperature during inspiration. Due to the interaction between several phenomena, it appears that the ratio of the amount of water returned to the mucosa during expiration to the amount extracted during inspiration is almost independent of the breathing conditions (around 33%). The results also show that, in acute situations, such as suffering from a pathology with airway dysfunction, when being intubated or when exercising above an intensity threshold, the heat and water exchanges in the lungs may be critical regarding mucus hydration. In proximal generations, the evaporation may overwhelm the ability of the submucosal glands to replenish the airway surface liquid with water. In some situations, the cooling of the mucosa may be very important; it can even become colder than the inspired air, due to evaporative cooling. Finally, the results show that breathing cold air can significantly increase the exchanges between the lungs and the environment, which can be critical regarding disease transmission.

19 October 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Jeremy RabineauJeremy Rabineau
Jeremy Rabineau
Amin HosseinAmin Hossein
Amin Hossein
FLFederica Landreani
Federica Landreani
BHBenoit Haut
Benoit Haut
EMEdwin Mulder
Edwin Mulder
PMPierre-François Migeotte
Pierre-François Migeotte
Head-down bed rest (HDBR) reproduces the cardiovascular effects of microgravity. We tested the hypothesis that regular high-intensity physical exercise (JUMP) could prevent this cardiovascular deconditioning, which could be detected using seismocardiography (SCG) and ballistocardiography (BCG). 23 healthy males were exposed to 60-day HDBR: 12 in a physical exercise group (JUMP), the others in a control group (CTRL). SCG and BCG were measured during supine controlled breathing protocols. From the linear and rotational SCG/BCG signals, the integral of kinetic energy ( $$iK$$ iK ) was computed on each dimension over the cardiac cycle. At the end of HDBR, BCG rotational $$iK$$ iK and SCG transversal $$iK$$ iK decreased similarly for all participants (− 40% and − 44%, respectively, p < 0.05), and so did orthostatic tolerance (− 58%, p < 0.01). Resting heart rate decreased in JUMP (− 10%, p < 0.01), but not in CTRL. BCG linear $$iK$$ iK decreased in CTRL (− 50%, p < 0.05), but not in JUMP. The changes in the systolic component of BCG linear iK were correlated to those in stroke volume and VO2 max (R = 0.44 and 0.47, respectively, p < 0.05). JUMP was less affected by cardiovascular deconditioning, which could be detected by BCG in agreement with standard markers of the cardiovascular condition. This shows the potential of BCG to easily monitor cardiac deconditioning.

26 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Amin HosseinAmin Hossein
Amin Hossein
Jeremy RabineauJeremy Rabineau
Jeremy Rabineau
DGDamien Gorlier
Damien Gorlier
JRJose Ignacio Juarez Del Rio
Jose Ignacio Juarez Del Rio
PBPhilippe van de Borne
Philippe van de Borne
ANAntoine Nonclercq
Antoine Nonclercq
Recent years have witnessed an upsurge in the usage of ballistocardiography (BCG) and seismocardiography (SCG) to record myocardial function both in normal and pathological populations. Kinocardiography (KCG) combines these techniques by measuring 12 degrees-of-freedom of body motion produced by myocardial contraction and blood flow through the cardiac chambers and major vessels. The integral of kinetic energy (iK) obtained from the linear and rotational SCG/BCG signals, and automatically computed over the cardiac cycle, is used as a marker of cardiac mechanical function. The present work systematically evaluated the test–retest (TRT) reliability of KCG iK derived from BCG/SCG signals in the short term (<15 min) and long term (3–6 h) on 60 healthy volunteers. Additionally, we investigated the difference of repeatability with different body positions. First, we found high short-term TRT reliability for KCG metrics derived from SCG and BCG recordings. Exceptions to this finding were limited to metrics computed in left lateral decubitus position where the TRT reliability was moderate-to-high. Second, we found low-to-moderate long-term TRT reliability for KCG metrics as expected and confirmed by blood pressure measurements. In summary, KCG parameters derived from BCG/SCG signals show high repeatability and should be further investigated to confirm their use for cardiac condition longitudinal monitoring.