Emanuela Lidia Petrescu

Dr. Emanuela Lidia Petrescu

Victor Babeș University of Medicine and Pharmacy Timișoara, Timişoara, Timiş, Romania
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 December 2024 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
FMFLorin Lucian Muntean
FLorin Lucian Muntean
IOIustin Olariu
Iustin Olariu
Diana MarianDiana Marian
Diana Marian
TOTeodora Olariu
Teodora Olariu
Emanuela Lidia PetrescuEmanuela Lidia Petrescu
Emanuela Lidia Petrescu
GDGeorge Andrei Draghici
George Andrei Draghici
Modern dentistry is turning towards natural sources to overcome the immunological, toxicological, aesthetic, and durability drawbacks of synthetic materials. Among the first biomaterials used as endosseous dental implants, mollusk shells also display unique features, such as high mechanical strength, superior toughness, hierarchical architecture, and layered, microporous structure. This review focusses on hydroxyapatite—a bioactive, osteoconductive, calcium-based material crucial for bone healing and regeneration. Mollusk-derived hydroxyapatite is widely available, cost-effective, sustainable, and a low-impact biomaterial. Thermal treatment coupled with wet chemical precipitation and hydrothermal synthesis are the most common methods used for its recovery since they provide efficiency, scalability, and the ability to produce highly crystalline and pure resulting materials. Several factors, such as temperature, pH, and sintering parameters, modulate the size, purity, and crystallinity of the final product. Experimental and clinical data support that mollusk shell-derived hydroxyapatite and its carbonated derivatives, especially their nanocrystaline forms, display notable bioactivity, osteoconductivity, and osteoinductivity without causing adverse immune reactions. These biomaterials are therefore highly relevant for specific dental applications, such as bone graft substitutes or dental implant coatings. However, continued research and clinical validation is needed to optimize the synthesis of mollusk shell-derived hydroxyapatite and determine its applicability to regenerative dentistry and beyond.

30 September 2022 in Microorganisms
Verified
Journal Article
Open access
PDF file
AMAdelina Geanina Mocanu
Adelina Geanina Mocanu
Dana StoianDana Stoian
Dana Stoian
Emanuela Lidia PetrescuEmanuela Lidia Petrescu
Emanuela Lidia Petrescu
ICIoana Mihaela Ciohat
Ioana Mihaela Ciohat
AMAlexandru Catalin Motofelea
Alexandru Catalin Motofelea
MCMarius L. Craina
Marius L. Craina
Background: Toxoplasma gondii (TG), a zoonotic protozoan parasite, belongs to a group of TORCH infectious agents, which can cause severe damage to the fetus if a primary infection occurs during pregnancy. After primary infection, TG rests lifelong in human organisms causing a latent infection. Most studies have analyzed the consequences of acute, but not latent, TG infection. This study analyzed the impact of latent toxoplasmosis on spontaneous abortion history, pregnancy complication rate and neonatal outcome. Methods: IgG and IgM anti-TG antibodies were tested in 806 pregnant women who were consulted at the Timisoara Clinical Emergency Hospital between 2008 and 2010. Demographic data, obstetrical history, and data about the pregnancy complications, birth and neonate were collected for each woman and comparisons between the groups, with and without latent TG infection, were made. Results: This study did not show differences between groups regarding the history of spontaneous abortion (OR = 1.288, p = 0.333), cesarean section (OR = 1.021, p = 0.884), placental abruption (OR 0.995, p = 0.266), pregnancy-induced hypertension rate (OR 1.083, p = 0.846), secondary sex ratio (1.043, p = 0.776), 1′ APGAR score at birth (p = 0.544), gestational age at birth (p = 0.491) or birth weight (p = 0.257). Conclusions: The observed differences between the rate of pregnancy complications in the two groups of pregnant women with and without latent infection with TG, did not reach a statistical significance.

28 January 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
CSChrista Serban
Christa Serban
DLDiana Lungeanu
Diana Lungeanu
SBSergiu-David Bota
Sergiu-David Bota
CCClaudia C. Cotca
Claudia C. Cotca
Meda-Lavinia NegrutiuMeda-Lavinia Negrutiu
Meda-Lavinia Negrutiu
Emanuela Lidia PetrescuEmanuela Lidia Petrescu
Emanuela Lidia Petrescu
This systematic review and meta-analysis aimed at assessing the diagnostic accuracy of emerging technologies, such as laser fluorescence (LF), transillumination, light-emitting diode devices, optical coherence tomography (OCT), alternating current impedance spectroscopy, fluorescence cameras (FC), photo-thermal radiometry, and modulated luminescence technology. In vivo and in vitro results of such non-ionizing, non-invasive, and non-destructive methods’ effectiveness in non-cavitated dentin caries detection are sometimes ambiguous. Following the PRISMA guidelines, 34 relevant research articles published between 2011–2021 were selected. The risk of bias was assessed with a tool tailored for caries diagnostic studies, and subsequent quantitative uni- and bi-variate meta-analysis was carried out in separate sub-groups according to the investigated surface (occlusal/proximal) and study setting (in vivo/in vitro). In spite of the high heterogeneity across the review groups, in vitro studies on LF and FC proved a good diagnostic ability for the occlusal surface, with area under the curve (AUC) of 0.803 (11 studies) and 0.845 (five studies), respectively. OCT studies reported an outstanding performance with an overall AUC = 0.945 (four studies). Promising technologies, such as OCT or FC VistaProof, still need well-designed and well-powered studies to accrue experimental and clinical data for conclusive medical evidence, especially for the proximal surface. Registration: INPLASY202210097.

4 April 2024 in Polymers
Verified
Journal Article
Open access
PDF file
ANANDREEA CODRUTA NOVAC
ANDREEA CODRUTA NOVAC
ATAnca Tudor
Anca Tudor
DPDaniela Maria Pop
Daniela Maria Pop
CNCarina-Sonia Neagu
Carina-Sonia Neagu
Emanuela Lidia PetrescuEmanuela Lidia Petrescu
Emanuela Lidia Petrescu
Cosmin SinescuCosmin Sinescu
Cosmin Sinescu
The impression materials utilized today in dental medicine offer a good reproducibility and are easily accepted by patients. However, because they are polymer-based, they have issues regarding their dimensional stability. In this respect, the present work proposes a new type of dental impression, which is reinforced with rigid mouthguards. The aim of the study is to test the performances of such new impressions by comparing them to conventional ones—from this critical point of view, of the dimensional stability. Three types of polymeric materials were considered for both types of impressions: alginate, condensation silicone, and addition silicone. In order to obtain the new type of impressions, a manufacturing technique was developed, comprising the following phases: (i) conventional impressions were made; (ii) a plaster model was duplicated, and 15 rigid mouthguards were obtained; (iii) they were inserted in the impression technique, with each mouthguard positioned on the cast before the high-consistency material was inserted in the tray and the practitioner took the impression; (iv) the mouthguard remained in the tray and the low-viscosity material was inserted over the mouthguard; (v) the impression was positioned on the model, and after the material hardened, the mouthguard-reinforced impression was analyzed. In the evaluation of the dimensional stability, rigorous statistical analysis was essential to discern the performance differences between conventional and mouthguard-reinforced dental impressions. Statistical analyses employed non-parametric Mann–Whitney U tests because of the non-normal distribution of the data. They indicated a statistically significant improvement in the dimensional stability of addition silicone impressions when reinforced with mouthguards (p < 0.05), showcasing superior performance over conventional methods. Conversely, alginate and condensation silicone reinforced impressions did not exhibit the same level of stability improvement, suggesting the need for further optimization of these materials. In conclusion, from the three considered elastomers, addition silicone was found to be the prime candidate for high-precision dental impressions, with the potential to improve their quality from conventional impressions by utilizing the proposed reinforcing technique.

17 March 2021 in Romanian Journal of Morphology and Embryology
Verified
Journal Article
Open access
MŢMarius-Mihai Ţogoe
Marius-Mihai Ţogoe
Emanuela Lidia PetrescuEmanuela Lidia Petrescu
Emanuela Lidia Petrescu
FTFlorin-Ionel Topală
Florin-Ionel Topală
CSCosmin Sinescu
Cosmin Sinescu
LNLuminiţa Maria Nica
Luminiţa Maria Nica
Meda-Lavinia NegrutiuMeda-Lavinia Negrutiu
Meda-Lavinia Negrutiu
Objectives: The goal of endodontic therapy is mechanically cleaning and shaping the root canal system, the removal of organic and inorganic debris followed by sealing with permanent filling materials. Materials and Methods: Therefore, the aim of this in vitro study was to engage three imagistic methods: (i) en face (ef) time domain (TD) optical coherence tomography (OCT), (i) micro-computed tomography (mu CT), and (i) scanning electron microscopy (SEM), in terms of their efficiency in assessing the quality of endodontic fillings. So far, is settled that efOCT images can identify defects/voids in several of the investigated root canal fillings and identify gaps of 50 mu m. Results: The results delivered by mu CT technology also showed several imperfections of the endodontic filling but also at the interfaces formed by the sealer and the root canal walls. SEM investigations highlights the complex form of the interface formed the endodontic filling material and the walls of the root canal, as well as shortcomings of the materials from several samples. Gaps of 50 mu m are identified with efOCT. Conclusions: The net advantage of OCT technology, in respect to the other two technologies consists in its non-invasiveness. The OCT axial resolution is also sufficient to see the material gaps. Another advantage of efOCT investigations is that they allow real-time imaging of complex arrangement at the interfaces of the filling material with dentinal root.

Verified
Journal Article
Open access
PDF file
CMCRISTINA MODIGA
CRISTINA MODIGA
ASAndreea Stoia
Andreea Stoia
MLMARIUS-TRAIAN LERETTER
MARIUS-TRAIAN LERETTER
ACAna-Codruta Chis
Ana-Codruta Chis
AAAndreea Violeta Ardelean
Andreea Violeta Ardelean
Emanuela Lidia PetrescuEmanuela Lidia Petrescu
Emanuela Lidia Petrescu
Background: Removable prostheses have seen a fundamental change recently because of advances in polymer materials, allowing improved durability and performance. Despite these advancements, notable differences still occur amongst various polymer materials and processing technologies, requiring a thorough grasp of their mechanical, physical, and therapeutic implications. The compressive strength of dentures manufactured using various technologies will be investigated. Methods: Traditional, injection molding, and additive and subtractive CAD/CAM processing techniques, all utilizing Polymethyl methacrylate (PMMA) as the main material, were used to construct complete dentures. The specimens underwent a compressive mechanical test, which reveals the differences in compressive strength. Results: All the specimens broke under the influence of a certain force, rather than yielding through flow, as is characteristic for plastic materials. For each specimen, the maximum force (N) was recorded, as well as the breaking energy. The mean force required to break the dentures for each processing technology is as follows: 4.54 kN for traditional packing-press technique, 17.92 kN for the injection molding technique, 1.51 kN for the additive CAD/CAM dentures, and 5.9 kN for the subtractive CAD/CAM dentures. Conclusions: The best results were obtained in the case of the thermoplastic injection system and the worst results were recorded in the case of 3D printed samples. Another important aspect depicted is the standard deviation for each group, which reveal a relatively unstable property for the thermoplastic injected dentures. Good results here in terms of absolute property and stability of the property can be conferred to CAD/CAM milled group.