Fast, economic, and noninvasive, molecular analysis of saliva has the potential to become a diagnostic tool of reference for several local and systemic diseases, oral cancer included. The diagnosis of Oral Squamous Cell Carcinoma (OSCC) can be performed using high specificity and sensibility biomarkers that can be encountered in the biological fluids. Recent advances in salivary proteomics have underlined the potential use of salivary biomarkers as early diagnosis screening tools for oral neoplasia. In this respect, over 100 salivary molecules have been described and proposed as oral cancer biomarkers, out of which cytokines are among the most promising. Besides being directly involved in inflammation and immune response, the role of salivary cytokines in tumor growth and progression linked them to the incidence of oral malignant lesions. This review summarizes the existing studies based on the use of salivary cytokines as potential oral cancer biomarkers, their involvement in the malignant process based on their type, and ther influence upon prognostic and metastatic rates.
A correct diagnosis in dental medicine is typically provided only after clinical and radiological evaluations. They are also required for treatment assessments. The aim of this study is to establish the boundaries from which a modern, although established, imaging technique, Optical Coherence Tomography (OCT), is more suitable than the common X-ray radiography to assess dental issues and treatments. The most common methods for daily-basis clinical imaging are utilized in this study for extracted teeth (but also for other dental samples and materials), i.e., panoramic, intraoral radiography, and three-dimensional (3D) cone beam computed tomography (CBCT). The advantages of using OCT as an imaging method in dentistry are discussed, with a focus on its superior image resolution. Drawbacks related to its limited penetration depth and Field-of-View (FOV) are pointed out. High-quality radiological investigations are performed, measurements are done, and data collected. The same teeth and samples are also imaged (mostly) with an in-house developed Swept Source (SS)-OCT system, Master-Slave enhanced. Some of the OCT investigations employed two other in-house developed OCT systems, Spectral Domain (SD) and Time Domain (TD). Dedicated toolbars from Romexis software (Planmeca, Helsinki, Finland) are used to perform measurements using both radiography and OCT. Clinical conclusions are drawn from the investigations. Upsides and downsides of the two medical imaging techniques are concluded for each type of considered diagnosis. For treatment assessments, it is concluded that OCT is more appropriate than radiography in all applications, except bone-related investigations and periodontitis that demand data from higher-penetration depths than possible with the current level of OCT technology.
28 June 2020 in International Journal of Dental Hygiene
Background and Objectives: Antiresorptive or anti-angiogenic agents may induce medication-related osteonecrosis of the jaws (MRONJ), which represents a challenge for clinicians. The aim of this study is to design and apply a composed and stage-approach therapy combining antibiotherapy, surgical treatment, and photo-biomodulation (PBM) for the prevention or treatment of MRONJ lesions. Materials and Methods: The proposed treatment protocol was carried out in the Department of Oral & Maxillofacial Surgery of the “Victor Babes” University of Medicine and Farmacy of Timisoara, in 2018–2020. A total of 241 patients who were previously exposed to antiresorptive or anti-angiogenic therapy, as well as patients already diagnosed with MRONJ at different stages of the disease were treated. A preventive protocol was applied for patients in an “at risk” stage. Patients in more advanced stages received a complex treatment. Results: The healing proved to be complete, with spontaneous bone coverage in all the n = 84 cases placed in an “at risk” stage. For the n = 49 patients belonging to stage 0, pain reductions and decreases of mucosal inflammations were also obtained in all cases. For the n = 108 patients proposed for surgery (i.e., in stages 1, 2, or 3 of MRONJ), a total healing rate of 91.66% was obtained after the first surgery, while considering the downscaling to stage 1 as a treatment “success”, only one “failure” was reported. This brings the overall “success” rate to 96.68% for a complete healing, and to 99.59% when downscaling to stage 1 is included in the healing rate. Conclusions: Therefore, the clinical outcome of the present study indicates that patients with MRONJ in almost all stages of the disease can benefit from such a proposed association of methods, with superior clinical results compared to classical therapies.
The most common imaging technique for dental diagnoses and treatment monitoring is X-ray imaging, which evolved from the first intraoral radiographs to high-quality three-dimensional (3D) Cone Beam Computed Tomography (CBCT). Other imaging techniques have shown potential, such as Optical Coherence Tomography (OCT). We have recently reported on the boundaries of these two types of techniques, regarding. the dental fields where each one is more appropriate or where they should be both used. The aim of the present study is to explore the unique capabilities of the OCT technique to optimize X-ray units imaging (i.e., in terms of image resolution, radiation dose, or contrast). Two types of commercially available and widely used X-ray units are considered. To adjust their parameters, a protocol is developed to employ OCT images of dental conditions that are documented on high (i.e., less than 10 μm) resolution OCT images (both B-scans/cross sections and 3D reconstructions) but are hardly identified on the 200 to 75 μm resolution panoramic or CBCT radiographs. The optimized calibration of the X-ray unit includes choosing appropriate values for the anode voltage and current intensity of the X-ray tube, as well as the patient’s positioning, in order to reach the highest possible X-rays resolution at a radiation dose that is safe for the patient. The optimization protocol is developed in vitro on OCT images of extracted teeth and is further applied in vivo for each type of dental investigation. Optimized radiographic results are compared with un-optimized previously performed radiographs. Also, we show that OCT can permit a rigorous comparison between two (types of) X-ray units. In conclusion, high-quality dental images are possible using low radiation doses if an optimized protocol, developed using OCT, is applied for each type of dental investigation. Also, there are situations when the X-ray technology has drawbacks for dental diagnosis or treatment assessment. In such situations, OCT proves capable to provide qualitative images.