Meda-Lavinia Negrutiu

Prof. Meda-Lavinia Negrutiu

1. Department of Prostheses Technology and Dental Materials, Faculty of Dental Medicine, Victor Babeş University of Medicine and Pharmacy Timisoara, Timisoara, Romania
+1
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2022 in Polymers
Verified
Journal Article
Open access
PDF file
CTCodruta Victoria Tigmeanu
Codruta Victoria Tigmeanu
Lavinia Cosmina ArdeleanLavinia Cosmina Ardelean
Lavinia Cosmina Ardelean
Laura-Cristina RusuLaura-Cristina Rusu
Laura-Cristina Rusu
Meda-Lavinia NegrutiuMeda-Lavinia Negrutiu
Meda-Lavinia Negrutiu
3D-printing application in dentistry not only enables the manufacture of patient-specific devices and tissue constructs, but also allows mass customization, as well as digital workflow, with predictable lower cost and rapid turnaround times. 4D printing also shows a good impact in dentistry, as it can produce dynamic and adaptable materials, which have proven effective in the oral environment, under its continuously changing thermal and humidity conditions. It is expected to further boost the research into producing a whole tooth, capable to harmoniously integrate with the surrounding periodontium, which represents the ultimate goal of tissue engineering in dentistry. Because of their high versatility associated with the wide variety of available materials, additive manufacturing in dentistry predominantly targets the production of polymeric constructs. The aim of this narrative review is to catch a glimpse of the current state-of-the-art of additive manufacturing in dentistry, and the future perspectives of this modern technology, focusing on the specific polymeric materials.

4 September 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Alexandra RoiAlexandra Roi
Alexandra Roi
Ciprian RoiCiprian Roi
Ciprian Roi
Meda-Lavinia NegrutiuMeda-Lavinia Negrutiu
Meda-Lavinia Negrutiu
Mircea RivisMircea Rivis
Mircea Rivis
Cosmin SinescuCosmin Sinescu
Cosmin Sinescu
Laura-Cristina RusuLaura-Cristina Rusu
Laura-Cristina Rusu
Fast, economic, and noninvasive, molecular analysis of saliva has the potential to become a diagnostic tool of reference for several local and systemic diseases, oral cancer included. The diagnosis of Oral Squamous Cell Carcinoma (OSCC) can be performed using high specificity and sensibility biomarkers that can be encountered in the biological fluids. Recent advances in salivary proteomics have underlined the potential use of salivary biomarkers as early diagnosis screening tools for oral neoplasia. In this respect, over 100 salivary molecules have been described and proposed as oral cancer biomarkers, out of which cytokines are among the most promising. Besides being directly involved in inflammation and immune response, the role of salivary cytokines in tumor growth and progression linked them to the incidence of oral malignant lesions. This review summarizes the existing studies based on the use of salivary cytokines as potential oral cancer biomarkers, their involvement in the malignant process based on their type, and ther influence upon prognostic and metastatic rates.

8 August 2014 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Open access
DDDorin Demian
Dorin Demian
Virgil-Florin DumaVirgil-Florin Duma
Virgil-Florin Duma
CSCosmin Sinescu
Cosmin Sinescu
Meda-Lavinia NegrutiuMeda-Lavinia Negrutiu
Meda-Lavinia Negrutiu
RCRamona Cernat
Ramona Cernat
Adrian PodoleanuAdrian Podoleanu
Adrian Podoleanu
Three simple and low-cost configurations of handheld scanning probes for optical coherence tomography have been developed. Their design and testing for dentistry applications are presented. The first two configurations were built exclusively from available off-the-shelf optomechanical components, which, to the best of our knowledge, are the first designs of this type. The third configuration includes these components in an optimized and ergonomic probe. All the designs are presented in detail to allow for their duplication in any laboratory with a minimum effort, for applications that range from educational to high-end clinical investigations. Requirements that have to be fulfilled to achieve configurations which are reliable, ergonomic—for clinical environments, and easy to build are presented. While a range of applications is possible for the prototypes developed, in this study the handheld probes are tested ex vivo with a spectral domain optical coherence tomography system built in-house, for dental constructs. A previous testing with a swept source optical coherence tomography system has also been performed both in vivo and ex vivo for ear, nose, and throat—in a medical environment. The applications use the capability of optical coherence tomography to achieve real-time, high-resolution, non-contact, and non-destructive interferometric investigations with micrometer resolutions and millimeter penetration depth inside the sample. In this study, testing the quality of the material of one of the most used types of dental prosthesis, metalo-ceramic is thus demonstrated.

1 January 2008 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
CSCosmin Sinescu
Cosmin Sinescu
Meda-Lavinia NegrutiuMeda-Lavinia Negrutiu
Meda-Lavinia Negrutiu
CTCarmen Todea
Carmen Todea
CBCosmin Balabuc
Cosmin Balabuc
LFLaura Filip
Laura Filip
Adrian PodoleanuAdrian Podoleanu
Adrian Podoleanu
The present study evaluates the potential of en-face optical coherence tomography (OCT) as a possible noninvasive high resolution method for supplying necessary information on the material defects of dental prostheses and microleakage at prosthetic interfaces. Teeth are also imaged after several treatment methods to asses material defects and microleakage at the tooth-filling interface, and the presence or absence of apical microleakage, as well as to evaluate the quality of bracket bonding on dental hard tissue. C-scan and B-scan OCT images as well as confocal images are acquired from a large range of samples. Gaps between the dental interfaces and material defects are clearly exposed.

6 November 2014 in Journal of Adhesion Science and Technology
Verified
Journal Article
Closed access
RORoxana Oancea
Roxana Oancea
Adrian BraduAdrian Bradu
Adrian Bradu
Cosmin SinescuCosmin Sinescu
Cosmin Sinescu
RNRadu Marcel Negru
Radu Marcel Negru
Meda-Lavinia NegrutiuMeda-Lavinia Negrutiu
Meda-Lavinia Negrutiu
Adrian PodoleanuAdrian Podoleanu
Adrian Podoleanu

16 September 2013 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
CMCorina Marcauteanu
Corina Marcauteanu
Adrian BraduAdrian Bradu
Adrian Bradu
CSCosmin Sinescu
Cosmin Sinescu
FTFlorin Ionel Topala
Florin Ionel Topala
Meda-Lavinia NegrutiuMeda-Lavinia Negrutiu
Meda-Lavinia Negrutiu
Adrian PodoleanuAdrian Podoleanu
Adrian Podoleanu
A fast swept-source optical coherence tomography (SS-OCT) system is employed to acquire volumes of dental tissue, in order to monitor the temporal evolution of dental wear. An imaging method is developed to evaluate the volume of tissue lost in ex vivo artificially induced abfractions and attritions. The minimal volume (measured in air) that our system could measure is 2352 μm3. A volume of 25,000 A-scans is collected in 2.5 s. All these recommend the SS-OCT method as a valuable tool for dynamic evaluation of the abfraction and attrition with remarkable potential for clinical use.