Fabio Poletto

Dr. Fabio Poletto


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 September 2019 in Energies
Verified
Journal Article
Open access
PDF file
sergio Bobbosergio Bobbo
sergio Bobbo
LFLaura Fedele
Laura Fedele
MCMarco Curcio
Marco Curcio
ABAnna Bet
Anna Bet
MCMichele De Carli
Michele De Carli
ABAdriana Bernardi
Adriana Bernardi
In the European Union (EU), buildings are responsible for about 40% of the total final energy consumption, and 36% of the European global CO2 emissions. The European Commission released directives to push for the enhancement of the buildings energy performance and identified, beside the retrofit of the current building stock, Heating, Ventilation, and Air Conditioning (HVAC) systems as the other main way to increase renewable energy sharing and overall building energy efficiency. For this purpose, Ground Source Heat Pumps (GSHPs) represent one of the most interesting technologies to provide energy for heating, cooling, and domestic water production in residential applications, ensuring a significant reduction (e.g., up to 44% compared with air-source heat pumps) of energy consumption and the corresponding emissions. At present, GSHPs mainly employ the refrigerant R410A as the working fluid, which has a Global Warming Potential (GWP) of 2087. However, following the EU Regulation No. 517/2014 on fluorinated greenhouse gases, this high GWP refrigerant will have to be substituted for residential applications in the next years. Thus, to increase the sustainability of GSHPs, it is necessary to identify short time alternative fluids with lower GWP, before finding medium-long term solutions characterized by very low GWP. This is one of the tasks of the UE project "Most Easy, Efficient, and Low-Cost Geothermal Systems for Retrofitting Civil and Historical Buildings" (acronym GEO4CIVHIC). Here, a thorough thermodynamic analysis, based on both energy and exergy analysis, will be presented to perform a comparison between different fluids as substitutes for R410A, considered as the benchmark for GSHP applications. These fluids have been selected considering their lower flammability with respect to hydrocarbons (mainly R290), that is one of the main concerns for the companies. A parametric analysis has been performed, for a reversible GSHP cycle, at various heat source and sink conditions, with the aim to identify the fluid giving the best energetic performance and to evaluate the distribution of the irreversibilities along the cycle. Considering all these factors, R454B turned out to be the most suitable fluid to use in a ground source heat pump, working at given conditions. Special attention has been paid to the compression phase and the heat transfer in evaporator and condenser.

29 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
GEGiuseppe Emmi
Giuseppe Emmi
SARA BORDIGNONSARA BORDIGNON
SARA BORDIGNON
LCLaura Carnieletto
Laura Carnieletto
MCMichele De Carli
Michele De Carli
Fabio PolettoFabio Poletto
Fabio Poletto
Adriana BernardiAdriana Bernardi
Adriana Bernardi
The energy-saving potential of heat pump technology is widely recognized in the building sector. In retrofit applications, especially in old and historic buildings, it may be difficult to replace the existing distribution and high-temperature emission systems. Often, historical buildings, especially the listed ones, cannot be thermally insulated; this leads to high temperatures of the heat carrier fluid for heating. In these cases, the main limits are related, on the one hand, to the reaching of the required temperatures, and on the other hand, to the obtaining of good performance even at high temperatures. To address these problems, a suitable solution can be a two-stage heat pump. In this work, a novel concept of a two-stage heat pump is proposed, based on a transcritical cycle that uses the natural fluid R744 (carbon dioxide) with an ejector system. The second refrigerant present in the heat pump and used for the high-temperature stage is the R1234ze, which is an HFO (hydrofluoro-olefin) fluid. This work aims to present the effective energy performance based on real data obtained in operating conditions in a monitoring campaign. The heat pump prototype used in this application is part of the H2020 Cheap-GSHP project, which was concluded in 2019.

27 April 2023 in Energies
Verified
Journal Article
Open access
PDF file
LFLaura Fedele
Laura Fedele
sergio Bobbosergio Bobbo
sergio Bobbo
DMDavide Menegazzo
Davide Menegazzo
MCMichele De Carli
Michele De Carli
LCLaura Carnieletto
Laura Carnieletto
ABAdriana Bernardi
Adriana Bernardi
The European building sector is responsible for approximately 40% of total energy consumption and for 36% of greenhouse gas emissions. Identifying technological solutions capable of reducing energy consumption and greenhouse gas emissions is one of the main objectives of the European Commission. Ground source heat pumps (GSHPs) are of particular interest for this purpose, promising a considerable reduction in greenhouse gas emissions of HVAC systems. This paper reports the results of the energetic analysis carried out within the EU research project GEO4CIVHIC about the performance of geothermal heat pumps working with low-GWP refrigerants as alternatives for R134a and R410A. The work has been carried out through computer simulations based on base and regenerative reverse cycles. Several heat sink and heat source temperature conditions have been considered in order to evaluate the GSHPs’ performance in the whole range of real conditions that can be found in Europe. Particular attention has been paid to the evaluation of compression isentropic efficiency and its influence on the overall cycle performance when dealing with steady-state heat pump simulations. To do so, five different scenarios of isentropic efficiency calculation have been studied and discussed.