The article explores the transformative role of 3D-printing in architectural and engineering research, with a specific focus on its application in producing scaled models for wind tunnel testing of photovoltaic (PV) systems. The study highlights how 3D-printing enables the creation of prototypes which can be essential for the investigation and optimisation of structural designs. A case study explores the use of advanced 3D-printing technologies in the fabrication of extremely accurate and intricate items, such as instrumented PV modules incorporating hollow channels for pressure measurements, gear, racks, and sliding components. The integration of PolyJet and SLS technologies combined with tailored materials and meticulous post-processing treatments (such as sandblasting, spray polymer coating, alkaline solution dip, etc.) ensured high precision, functionality, and adaptability. This approach significantly reduced production time and costs while enhancing the reliability of experimental results. The findings underscore the potential of 3D-printing to revolutionise experimental methodologies, facilitating rapid design iterations and fostering innovation in sustainable and resilient building design.
The paper deals with the use of Computational Fluid Dynamics (CFD) for the thermal performance analysis and optimisation of prefabricated Timber-Concrete Composite (TCC) ventilated façades. TCC envelopes are composed of an internal insulated timber-frame wall coupled to an external concrete slab, separated by a ventilated air cavity. Such systems join the properties of engineered timber (good seismic behaviour, low thermal conductivity, environmental sustainability, and ease of system integration) with those of concrete (high thermal inertia, excellent durability and fire resistance). There is very limited knowledge on the performance of TCC facades, especially for what concerns their thermal behaviour. For this reason, a TCC ventilated façade located in the north of Italy was monitored over one year, and the results collected were used to calibrate and validate a CFD model. A new solver algorithm was developed to speed up the CFD simulations, allowing up to 45 times faster analysis compared to conventional solvers. Thanks to this improvement, the final model is suitable to be used for time-efficient thermal analysis (a full-day real-time simulation takes approximately 23 minutes), limiting the expensive and time-consuming construction of mock-ups. The CFD model developed is suitable for the thermal performance analysis and optimisation of TCC ventilated facades, but also for generic ventilated facades with external massive cladding, both in the case of new and existing buildings.
The integration of tilted photovoltaic strings on large, flat roofs, typical of industrial and commercial buildings, raises complex design challenges, particularly regarding wind-induced loads. This study presents a comprehensive wind tunnel investigation aimed at evaluating the aerodynamic effects on rooftop PV strings under various representative configurations and the correlation between characteristic geometric parameters such as tilt angle, bottom clearance, row spacing, and wind direction. Following a literature review, a detailed 1:10 scaled model with geometric adjustment capabilities was developed and eventually tested in a boundary-layer wind tunnel. High-resolution pressure measurements were processed to derive force and moment resultants normalised by reference wind pressure. Envelopes of force/moment resultants are presented for each representative geometric configuration and for each wind exposure angle. The results present severe variations in local wind actions, particularly significant at the strings’ free ends and for oblique wind angles. The severe underestimation of local wind loads by standard codes is discussed. The findings underline the importance of detailed wind-load assessment for both new constructions and retrofits, suggesting that reliance solely on code provisions might result in unsafe designs.