Sofia Pastori

Dr. Sofia Pastori

Politecnico di Milano - Department of Architecture, Built environment and Construction engineering
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Energies
Verified
Journal Article
Open access
PDF file
Sofia PastoriSofia Pastori
Sofia Pastori
RMRiccardo Mereu
Riccardo Mereu
EMEnrico Sergio Mazzucchelli
Enrico Sergio Mazzucchelli
SPStefano Passoni
Stefano Passoni
Giovanni DotelliGiovanni Dotelli
Giovanni Dotelli
Ventilated façades can help to reduce summer building thermal loads and, therefore, energy consumption due to air-conditioning systems thanks to the combined effect of the solar radiation reflection and the natural or forced ventilation into the cavity. The evaluation of ventilated façades behavior and performance is complex and requires a complete thermo-fluid dynamic analysis. In this study, a computational fluid dynamic (CFD) methodology has been developed for the complete assessment of the energy performance of a prefabricated timber–concrete composite ventilated façade module in different operating conditions. Global numerical results are presented as well as local ones in terms of heat flux, air velocity, and temperature inside the façade cavity. The results show the dependency of envelope efficiency on solar radiation, the benefits that natural convection brings on potential energy savings and the importance of designing an optimized façade geometry. The results concerning the façade behavior have been thoroughly compared with International Standards, showing the good accuracy of the model with respect to these well-known procedures. This comparison allowed also to highlight the International Standards procedures limits in evaluating the ventilated façade behavior with the necessary level of detail, with the risk of leading to design faults.

20 December 2023
Verified
Book Chapter
Open access
PDF file
Sofia PastoriSofia Pastori
Sofia Pastori
EMEnrico Sergio Mazzucchelli
Enrico Sergio Mazzucchelli
The frequency and intensity of extreme weather events have increased in the last few years. Buildings resiliency against natural hazards (hurricanes, flooding, wildfires, etc.) is fundamental for the adaptation to climate change, however it is hardly included in their design. Buildings exposed to extreme climate conditions may become drivers of vulnerability, rather than providing shelter for users, leading to human and economic losses. The building stock assessment appears to be quite detailed about seismic vulnerability and energy demand related to climate change, but not towards other hazardous events, such as extreme winds. Furthermore, climate data provided by current standards and used for building design need to be seriously reconsidered, since they no longer represent the real weather variables. During windstorms, the main threats are mainly due to the detaching and flying of materials and elements from buildings and urban furniture. The chapter deals with the effects and consequences of strong wind events on the built heritage and calls for an urban transition to create resilient and safe environments for the people. An overview of the current standards related to building design against wind is presented, and mitigation and adaptation strategies are proposed to respond to current and future climate threats.

9 November 2024 in Buildings
Verified
Journal Article
Open access
PDF file
Sofia PastoriSofia Pastori
Sofia Pastori
MSMohammadsadegh Salehi
Mohammadsadegh Salehi
SRStefan Radl
Stefan Radl
EMEnrico Sergio Mazzucchelli
Enrico Sergio Mazzucchelli
Timber–concrete composite (TCC) systems join the positive aspects of engineered wood products (good seismftaic behaviour, low thermal conductivity, environmental sustainability, good behaviour under fire if appropriately designed) with those of concrete (high thermal inertia, durability, excellent fire resistance). TCC facades are typically composed of an internal insulated timber-frame wall and an external concrete slab, separated by a ventilated air cavity. However, there is very limited knowledge concerning the performance of TCC facades, especially concerning their thermal behaviour. The present paper deals with the development and optimization of a 2D Computational Fluid Dynamic (CFD) model for the analysis of TCC ventilated façades’ thermal behaviour. The model is calibrated and validated against experimental data collected during the annual monitoring of a real TCC ventilated envelope in the north of Italy. Also, a new solver algorithm is developed to significantly speed up the simulation (i.e., 45 times faster simulation at an error below 3.5 °C compared to a typical CFD solver). The final model can be used for the time-efficient analysis (simulation time of approximately 23 min for a full day in real-time) and the optimization of the thermal performance of TCC ventilated facades, as well as other ventilated facades with external massive cladding. Our simulation strategy partially avoids the expensive and time-consuming construction of mock-ups, or the use of comparably slow (conventional) CFD solvers that are less suitable for optimization studies.

30 April 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
Sofia PastoriSofia Pastori
Sofia Pastori
MSMohammadsadegh Salehi
Mohammadsadegh Salehi
SRStefan Radl
Stefan Radl
EMEnrico Sergio Mazzucchelli
Enrico Sergio Mazzucchelli
Timber-concrete composite (TCC) systems join the positive aspects of engineered wood products (good seismic behaviour, low thermal conductivity, environmental sustainability, good behaviour under fire if appropriately designed) with those of concrete (high thermal inertia, durability, excellent fire resistance). TCC facades are typically composed by an internal insulated timber-frame wall and an external concrete slab, separated by a ventilated air cavity. However, there is very limited knowledge concerning the performance of TCC facades, especially for what concerns their thermal behaviour. The present paper deals with the development and optimisation of a 2D CFD model for the analysis of TCC ventilated façades thermal behaviour. The model is calibrated and validated against the experimental data collected during the annual monitoring of a real TCC ventilated envelope in the north of Italy. Also, a new solver algorithm is developed to significantly speed up the simulation. The final model can be used for the time-efficient analysis and optimisation of the thermal performance of TCC ventilated facades, as well as other ventilated facades with external massive cladding, avoiding the expensive and time-consuming construction of mock-ups, or the use of comparably slow (conventional) CFD solvers that are less suitable for optimization studies.


5 December 2025 in Rivista Tema
Verified
Journal Article
Open access
PDF file
Sofia PastoriSofia Pastori
Sofia Pastori
Giacomo ScrinziGiacomo Scrinzi
Giacomo Scrinzi
EMEnrico Sergio Mazzucchelli
Enrico Sergio Mazzucchelli
ALAngelo Lucchini
Angelo Lucchini
The paper deals with the use of Computational Fluid Dynamics (CFD) for the thermal performance analysis and optimisation of prefabricated Timber-Concrete Composite (TCC) ventilated façades. TCC envelopes are composed of an internal insulated timber-frame wall coupled to an external concrete slab, separated by a ventilated air cavity. Such systems join the properties of engineered timber (good seismic behaviour, low thermal conductivity, environmental sustainability, and ease of system integration) with those of concrete (high thermal inertia, excellent durability and fire resistance). There is very limited knowledge on the performance of TCC facades, especially for what concerns their thermal behaviour. For this reason, a TCC ventilated façade located in the north of Italy was monitored over one year, and the results collected were used to calibrate and validate a CFD model. A new solver algorithm was developed to speed up the CFD simulations, allowing up to 45 times faster analysis compared to conventional solvers. Thanks to this improvement, the final model is suitable to be used for time-efficient thermal analysis (a full-day real-time simulation takes approximately 23 minutes), limiting the expensive and time-consuming construction of mock-ups. The CFD model developed is suitable for the thermal performance analysis and optimisation of TCC ventilated facades, but also for generic ventilated facades with external massive cladding, both in the case of new and existing buildings.