Ventilated façades can help to reduce summer building thermal loads and, therefore, energy consumption due to air-conditioning systems thanks to the combined effect of the solar radiation reflection and the natural or forced ventilation into the cavity. The evaluation of ventilated façades behavior and performance is complex and requires a complete thermo-fluid dynamic analysis. In this study, a computational fluid dynamic (CFD) methodology has been developed for the complete assessment of the energy performance of a prefabricated timber–concrete composite ventilated façade module in different operating conditions. Global numerical results are presented as well as local ones in terms of heat flux, air velocity, and temperature inside the façade cavity. The results show the dependency of envelope efficiency on solar radiation, the benefits that natural convection brings on potential energy savings and the importance of designing an optimized façade geometry. The results concerning the façade behavior have been thoroughly compared with International Standards, showing the good accuracy of the model with respect to these well-known procedures. This comparison allowed also to highlight the International Standards procedures limits in evaluating the ventilated façade behavior with the necessary level of detail, with the risk of leading to design faults.
1 November 2020 in IOP Conference Series: Earth and Environmental Science
The research here presented deals with the relationship between vegetation and architecture, and how its presence can influence a building project and performance. In the last years, many ways of integrating green in building envelopes have already been experimented, for their potential of reducing thermal loads; the research investigates a specific solution, the vertical forest, which integrates trees and small bushes in specific permanent planters on balconies of high-rise buildings. The main scope is to understand if trees, treated as shadings, can really affect positively the building energy consumptions. Moreover, other aspects, such as trees mechanical stability, construction issues and maintenance are deepened. Through a particular case study, energy consumptions are analysed using dynamic simulations tools, developed with Grasshopper™ and EnergyPlus™ software, in which trees are considered as special external shadings, characterized by a variable permeability to solar radiation during the year. Results demonstrate that trees can contribute to reduce energy loads, depending on species and orientation, especially in association with traditional shading systems. Eventually, some guidelines on technological and construction aspects, as well as on trees species selection, are given, in order to assure the optimal vegetation life and to maximize its benefits on the building.
Aluminium has become a cornerstone of sustainable architectural design due to its lightweight properties, structural strength, corrosion resistance, and high recyclability. However, its primary production remains energy-intensive and a major contributor to greenhouse gas (GHG) emissions. This study presents a comparative Life Cycle Assessment (LCA) of commonly used aluminium alloys in architectural components, evaluating them across key stages—production and end-of-life—based on energy consumption, emissions, and recyclability. The analysis covers 3000, 5000 and 6000-series alloys, as well as recycled, anodized, and coated variants. The study contributes a parameterized LCA-based framework to support sustainable material selection in façade and structural design. It highlights the importance of incorporating recycled content, optimizing alloy use based on application, and adopting circular economy strategies such as closed-loop recycling. These findings offer practical guidance for architects, engineers, and policymakers striving toward low-carbon, net-zero building goals.
This paper presents a study of the thermo-hygrometric behaviour of a Double Skin Façade (DSF) unit. The study aims (i) at comparing currently used calculation procedures according to European and American standards (UNI EN ISO 10077, UNI EN ISO 12631:2018, ISO 15099:2003, ANSI/NFRC 100 for the thermal performance and ISO 13788:2012 (2012) for the condensation risk), and (ii) at assessing the 2D hygrothermal performance of a double skin module through a Finite Element Method (FEM)-based model. According to the current standards, a detailed characterization of thermal and fluid dynamic phenomena in closed and ventilated cavities is neglected and a simplified approach is proposed, which tends to overestimate the overall U-value of the curtain wall (UCW) due to an incremental thermal resistance that depends on the thickness of the air gap layer and the level of ventilation. The potential risk of this simplification is that the DSF estimated design performance, whilst complying with regulatory requirements, present inconsistencies respect to the real behaviour, impacting energy, comfort, material degradation, etc. Accurate assessments could be done already during design through detailed FEM multi-physic analyses. Nevertheless, those require a specific knowledge, are cost and time-consuming. As a first step, this study focuses on comparing the normed calculation approach for the design, against a detailed FEM-based multi-physics methodology. Specifically, this couples CFD, hygrothermal and Ray Tracing physics in a tool for the calculation of thermal transmittance, g-value and relative humidity of a DSF with a customizable geometry. As a second step, given a real DSF unit that showed unforeseen phenomena of surface condensation inside the cavity during several hours in spring and autumn, the multi-physic tool has been used to evaluate the condensation risk with the current and modified DSF design, under static and time-dependent boundary conditions.
Timber–concrete composite (TCC) systems join the positive aspects of engineered wood products (good seismftaic behaviour, low thermal conductivity, environmental sustainability, good behaviour under fire if appropriately designed) with those of concrete (high thermal inertia, durability, excellent fire resistance). TCC facades are typically composed of an internal insulated timber-frame wall and an external concrete slab, separated by a ventilated air cavity. However, there is very limited knowledge concerning the performance of TCC facades, especially concerning their thermal behaviour. The present paper deals with the development and optimization of a 2D Computational Fluid Dynamic (CFD) model for the analysis of TCC ventilated façades’ thermal behaviour. The model is calibrated and validated against experimental data collected during the annual monitoring of a real TCC ventilated envelope in the north of Italy. Also, a new solver algorithm is developed to significantly speed up the simulation (i.e., 45 times faster simulation at an error below 3.5 °C compared to a typical CFD solver). The final model can be used for the time-efficient analysis (simulation time of approximately 23 min for a full day in real-time) and the optimization of the thermal performance of TCC ventilated facades, as well as other ventilated facades with external massive cladding. Our simulation strategy partially avoids the expensive and time-consuming construction of mock-ups, or the use of comparably slow (conventional) CFD solvers that are less suitable for optimization studies.
Timber-concrete composite (TCC) systems join the positive aspects of engineered wood products (good seismic behaviour, low thermal conductivity, environmental sustainability, good behaviour under fire if appropriately designed) with those of concrete (high thermal inertia, durability, excellent fire resistance). TCC facades are typically composed by an internal insulated timber-frame wall and an external concrete slab, separated by a ventilated air cavity. However, there is very limited knowledge concerning the performance of TCC facades, especially for what concerns their thermal behaviour. The present paper deals with the development and optimisation of a 2D CFD model for the analysis of TCC ventilated façades thermal behaviour. The model is calibrated and validated against the experimental data collected during the annual monitoring of a real TCC ventilated envelope in the north of Italy. Also, a new solver algorithm is developed to significantly speed up the simulation. The final model can be used for the time-efficient analysis and optimisation of the thermal performance of TCC ventilated facades, as well as other ventilated facades with external massive cladding, avoiding the expensive and time-consuming construction of mock-ups, or the use of comparably slow (conventional) CFD solvers that are less suitable for optimization studies.