We review the advancement of the research toward the design and implementation of quantum plenoptic cameras, radically novel 3D imaging devices that exploit both momentum–position entanglement and photon–number correlations to provide the typical refocusing and ultra-fast, scanning-free, 3D imaging capability of plenoptic devices, along with dramatically enhanced performances, unattainable in standard plenoptic cameras: diffraction-limited resolution, large depth of focus, and ultra-low noise. To further increase the volumetric resolution beyond the Rayleigh diffraction limit, and achieve the quantum limit, we are also developing dedicated protocols based on quantum Fisher information. However, for the quantum advantages of the proposed devices to be effective and appealing to end-users, two main challenges need to be tackled. First, due to the large number of frames required for correlation measurements to provide an acceptable signal-to-noise ratio, quantum plenoptic imaging (QPI) would require, if implemented with commercially available high-resolution cameras, acquisition times ranging from tens of seconds to a few minutes. Second, the elaboration of this large amount of data, in order to retrieve 3D images or refocusing 2D images, requires high-performance and time-consuming computation. To address these challenges, we are developing high-resolution single-photon avalanche photodiode (SPAD) arrays and high-performance low-level programming of ultra-fast electronics, combined with compressive sensing and quantum tomography algorithms, with the aim to reduce both the acquisition and the elaboration time by two orders of magnitude. Routes toward exploitation of the QPI devices will also be discussed.
Techniques based on classical and quantum correlations in light beams, such as ghost imaging, allow us to overcome many limitations of conventional imaging and sensing protocols. Despite their advantages, applications of such techniques are often limited in practical scenarios where the position and the longitudinal extension of the target object are unknown. In this work, we propose and experimentally demonstrate an imaging technique, named light-field ghost imaging, that exploits light correlations and light-field imaging principles to enable going beyond the limitations of ghost imaging in a wide range of applications. Notably, our technique removes the requirement to have prior knowledge of the object distance, allowing the possibility of refocusing in postprocessing, as well as performing three-dimensional imaging while retaining all the benefits of ghost imaging protocols. Published by the American Physical Society 2024
Diffraction-limited light-field imaging has been recently achieved by exploiting light spatial correlations measured on two high-resolution detectors. As in conventional light-field imaging, the typical operations of refocusing and 3D reconstruction are based on ray tracing in a geometrical optics context, and are thus well defined in the ideal case, both conceptually and theoretically. However, some properties of the measured correlation function are influenced by experimental features such as the finite size of apertures, detectors, and pixels. In this work, we take into account realistic experimental conditions and analyze the resulting correlation function through theory and simulation. We also provide an expression to evaluate the pixel-limited resolution of the refocused images, as well as a strategy for eliminating artifacts introduced by the finite size of the optical elements.
Correlation plenoptic imaging (CPI) is a technique capable of acquiring the light field emerging from a scene of interest, namely, the combined information of intensity and propagation direction of light. This is achieved by evaluating correlations between the photon numbers measured by two high-resolution detectors. Volumetric information about the object of interest is decoded, through data analysis, from the measured four-dimensional correlation function. In this paper, we investigate the relevant aspects of the refocusing algorithm, a post-processing method that isolates the image of a selected transverse plane within the 3D scene, once applied to the correlation function. In particular, we aim at bridging the gap between existing literature, which only deals with refocusing algorithms in case of continuous coordinates, and the experimental reality, in which the correlation function is available as a discrete quantity defined on the sensors pixels.
Wide‐field imaging is widely adopted due to its fast acquisition, cost‐effectiveness, and ease of use. Its extension to direct volumetric applications, however, is burdened by the trade‐off between resolution and depth of field (DOF), dictated by the numerical aperture of the system. It is demonstrated that such trade‐off is not intrinsic to wide‐field imaging, but stems from the spatial incoherence of light: images obtained through spatially coherent illumination are shown to have resolution and DOF independent of the numerical aperture. This fundamental discovery enables to demonstrate an optimal combination of coherent resolution‐DOF enhancement and incoherent tomographic sectioning for scanning‐free, wide‐field 3D microscopy on a multicolor histological section.
13 August 2024 in The European Physical Journal Plus
Correlation plenoptic imaging (CPI) is emerging as a promising approach to light-field imaging (LFI), a technique enabling simultaneous measurement of light intensity distribution and propagation direction from a scene. LFI allows single-shot 3D sampling, offering fast 3D reconstruction for a wide range of applications. However, the array of micro-lenses typically used in LFI to obtain 3D information limits image resolution, which rapidly declines with enhanced volumetric reconstruction capabilities. CPI addresses this limitation by decoupling the measurement of the light field on two photodetectors with spatial resolution, eliminating the need for micro-lenses. 3D information is encoded in a four-dimensional correlation function, which is decoded in post-processing to reconstruct images without the resolution loss seen in conventional LFI. This paper evaluates the tomographic performance of CPI, demonstrating that the refocusing reconstruction method provides axial sectioning capabilities comparable to conventional imaging systems. A general-purpose analytical approach based on image fidelity is proposed to quantitatively study axial and lateral resolution. The analysis fully characterizes the volumetric resolution of any CPI architecture, offering a comprehensive evaluation of its imaging performance.