Gökçe Keçeci

Dr. Gökçe Keçeci

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
İKİREM KARAGÖZOĞLU
İREM KARAGÖZOĞLU
NDNermin Demirkol
Nermin Demirkol
OOOZGE PARLAR OZ
OZGE PARLAR OZ
GKGökçe Keçeci
Gökçe Keçeci
BÇBeste Çetin
Beste Çetin
Mutlu ÖzcanMutlu Özcan
Mutlu Özcan
Background: Trigeminal neuralgia (TN) is a disease that causes severe pain that can seriously affect the quality of life. This study aimed to compare the effectiveness of two different low-level laser therapies (LLLT) as alternatives to medical treatment to reduce pain and improve the quality of life in patients with TN. Methods: A total of 45 patients were randomly divided into 3 groups. In the first group, a new-generation diode laser (GRR laser) was applied at predetermined points in the trigeminal nerve line. In the second group, a low-level neodymium-doped yttrium aluminum garnet (Nd:YAG) laser was applied along the affected nerve line. The placebo group received the same protocol with a Nd:YAG laser without the device switched on. The scores were recorded pre- and post-treatment using the Brief Pain Inventory-Facial (BPI-facial) scale. Results: A statistically significant difference was found between the pre- and post-treatment values of all four variables in the GRR laser, Nd:YAG laser, and placebo groups. When the post-treatment values were compared, statistically significant differences were found between the groups in pain frequency, pain intensity, and interference in facial-specific activities, but no differences were found in general activities. Conclusions: Both LLLTs can be considered alternative treatment modalities for TN, but the GRR laser treatment was more effective than the Nd:YAG laser treatment in reducing pain and improving the quality of life in patients with TN.

22 January 2026 in European Journal of Therapeutics
Verified
Journal Article
Open access
PDF file
GKGökçe Keçeci
Gökçe Keçeci
ZGZehra Güner
Zehra Güner
SŞSüleyman Ziya Şenyurt
Süleyman Ziya Şenyurt
KEKamile Erciyas
Kamile Erciyas
Objective: The aim of this study is to comparatively evaluate how the color stability of different esthetic composite resins and natural anterior teeth is affected after exposure to thermal aging and various mouthrinse solutions. Materials and Methods: A total of 96 extracted permanent anterior teeth were prepared with Class V cavities on the buccal surfaces and restored using three different esthetic composite resins: G-aenial Anterior (GC Corp., Tokyo, Japan), SOLARE X (GC Corp., Tokyo, Japan), and Estelite Sigma Quick (Tokuyama Dental Corp., Tokyo, Japan). The palatal surfaces of the same teeth were used as a natural enamel reference. Following restoration, all specimens underwent thermal aging for 10,000 cycles between 5 °C and 55 °C. Subsequently, the samples were immersed for 24 hours in four different mouthrinse solutions: 0.12% chlorhexidine solution (Kloroben, Drogsan, Türkiye), an antiseptic and anticavity formulation (Listerine Total Care, Johnson & Johnson, USA), a zinc-containing mouthrinse (Listerine Total Care Stay White, Johnson & Johnson, UK), and distilled water (control group). Color measurements were performed using a VITA Easyshade Advance 4.0 spectrophotometer, and color differences were calculated according to the CIEDE2000 (ΔE₀₀) formula. Results: Color changes were observed in all composite materials after thermal aging and exposure to mouth-rinse solutions. Specimens exposed to chlorhexidine-containing solutions exhibited significantly greater discoloration compared with the control group (p < 0.050). Statistically significant differences in color stability were also found among the materials (p < 0.050). Conclusion: Within the limitations of this in vitro study, chlorhexidine-containing mouthrinse caused the highest color change, while material type significantly influenced color stability.

30 March 2026 in Odontology
Verified
Journal Article
Open access
GKGökçe Keçeci
Gökçe Keçeci
ZGZehra Güner
Zehra Güner
SGsimge gümüş
simge gümüş
ABAyşenur güngör borsöken
Ayşenur güngör borsöken
The aim of this study was to evaluate the color stability of contemporary bioactive restorative materials, including Equia Forte HT, GC Fuji II LC, ACTIVA BioACTIVE, Cention N, and a conventional composite resin, and to comparatively analyze their color changes following thermal aging and exposure to iron preparations. A total of 120 specimens were fabricated from five different restorative materials: Equia Forte, Cention N, ACTIVA BioACTIVE, Fuji II, and SolareX ( n = 24 per group). All samples were initially subjected to thermal cycling, followed by immersion in two iron-containing solutions (Ferrum and Ocean) and one control solution (distilled water) for 72 h. Measurements were recorded at baseline (after 24 h of immersion in distilled water), after thermal cycling, and following staining procedures. Color difference (ΔE00) and lightness ( L *) values were quantitatively assessed using a dental spectrophotometer based on the CIEDE2000 color evaluation system. Statistical analyses were performed using the Shapiro–Wilk test, Kruskal–Wallis test, and generalized linear models (GLM) approach. All analyses were conducted with SPSS version 22.0, with a significance level set at p < 0.05. A statistically significant difference was observed between the baseline and post-aging color values ( p < 0.05). Among the materials tested, Equia Forte exhibited the greatest degree of color change, while ACTIVA BioACTIVE and SolareX demonstrated similar and comparatively lower levels of discoloration. Although no statistically significant difference was found between ACTIVA BioACTIVE and SolareX regarding total color change from baseline to final measurements ( p > 0.05), the ΔE2 values of Equia Forte, Cention N, and Fuji II were significantly higher than those of the SolareX group ( p < 0.05). Furthermore, significant differences were noted in the L * values before and after aging depending on the restorative material used ( p < 0.05). Equia Forte showed the lowest L * values at both baseline (L1) and post-aging (L2), whereas ACTIVA BioACTIVE and SolareX presented the highest values. The findings of this in vitro study suggest that the color stability of restorative materials is influenced by intrinsic material properties as well as exposure to thermal aging and staining solutions. These factors should be considered when selecting restorative materials, particularly in esthetically demanding clinical situations.

29 April 2026 in Akdeniz Diş Hekimliği Dergisi
Verified
Journal Article
Closed access
SÖSevgi Öğüt
Sevgi Öğüt
GKGökçe Keçeci
Gökçe Keçeci
BÇBeste ÇETİN
Beste ÇETİN
ObjectivesThis study aimed to examine the distribution of theses published in the Department of Prosthodontics in the National Thesis Center of Türkiye between 2015 and 2025 according to year, university, thesis type, subject, methodology and academic titles of the supervisors using bibliometric analysis and to evaluate the current status and development trends of postgraduate research in the field. Material and Methods Doctoral and specialty theses completed in the field of Department of Prosthodontics between 2015 and 2025 and publicly accessible in the National Thesis Center of Türkiye were included in the study. Results A total of 1203 theses were completed in the field of prosthodontics between 2015 and 2025. Of these, 741 (61.60%) were specialty theses and 462 (38.40%) were doctoral theses. The year with the highest thesis production was 2022 (15.30%), while the lowest was 2016 (4.41%). The majority of theses were conducted at state universities (91.36%), whereas 8.64% were completed at foundation universities. In vitro studies constituted the majority of theses (84.05). When the subject distribution was examined, it was observed that dental materials and laboratory processes (23.36%), implant and implant-supported prosthetic applications (19.20%) and cementation and adhesive systems (14.96%) were the most frequently studied topics. In terms of the academic title of the supervisors, professors were found to be in the majority. In addition, 65.75% of the theses were prepared by female researchers. ConclusionThe results indicate that a materials-focused and laboratory-oriented research profile in Prosthodontics is increasingly being shaped under the guidance of senior academics.

3 January 2026 in Coatings
Verified
Journal Article
Open access
PDF file
ZGZehra Güner
Zehra Güner
GKGökçe Keçeci
Gökçe Keçeci
SOSadık Olguner
Sadık Olguner
HÇHAKAN ÇANDAR
HAKAN ÇANDAR
ABAyşenur güngör borsöken
Ayşenur güngör borsöken
STSebnem Turkun
Sebnem Turkun
This study aimed to evaluate the effects of thermal cycling and restorative material type on surface roughness of material surfaces and dental interfaces using a non-contact profilometer. Ninety Class V cavities (2 mm × 4 mm × 2 mm in height, width, and depth) were prepared on extracted third molars and restored with four bio-interactive materials (Equia Forte, Cention-N, Activa BioActive Restorative, Fuji II LC) and one composite resin (Solare-X) (n = 18/group). After polishing (Optidisc), initial surface roughness (Sa, µm) was measured following 24 h immersion in distilled water. Measurements were performed at cement/material (400 × 1600 μm2), enamel/material (1600 × 400 μm2), and material surfaces (800 × 800 μm2). Samples underwent 10,000 thermal cycles (5–55 °C) to simulate aging, and roughness was re-measured. Data were analyzed with two-way repeated measures ANOVA and Tukey’s post hoc test (p < 0.05). Solare-X showed the lowest roughness, while Fuji II LC and Activa BioActive Restorative were smoother than Cention-N and Equia Forte (p < 0.01). All materials exhibited significant roughness increases after thermal cycling (p < 0.01). Cement/material and enamel/material interfaces consistently showed higher roughness than material surfaces (p < 0.01). Thermal cycling significantly increased surface roughness of all tested materials. Interfaces demonstrated greater roughness than material surfaces, indicating higher susceptibility to plaque retention and potential risk for long-term restoration success.