Hari Prakash Yadav

Mr. Hari Prakash Yadav

Indian institute of Technology BHU Varanasi
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2021 in Chemosensors
Verified
Journal Article
Open access
PDF file
Prem Chandra PandeyPrem Chandra Pandey
Prem Chandra Pandey
Hari Prakash YadavHari Prakash Yadav
Hari Prakash Yadav
SSShubhangi shukla
Shubhangi shukla
Roger J. NarayanRoger J. Narayan
Roger J. Narayan
Selective screening followed by the sensing of cesium radionuclides from contaminated water is a challenging technical issue. In this study, the adsorption functionality of Prussian blue (PB) nanoparticles was utilized for the detection and efficient removal of cesium cations. An efficient PB nanoparticle-modified screen-printed electrode (SPE) in the three-electrode configuration was developed for the electrochemical sensing and removal of Cs+. PB nanoparticles inks were obtained using a facile two-step process that was previously described as suitable for dispensing over freshly prepared screen-printed electrodes. The PB nanoparticle-modified SPE induced a cesium adsorption-dependent chronoamperometric signal based on ion exchange as a function of cesium concentration. This ion exchange, which is reversible and rapid, is associated with electron transfer in the PB nanoparticle-modified SPE. Using this electrochemical adsorption system (EAS) based on chronoamperometry, the maximum adsorption capacity (Qmax) of Cs+ ions in the PB nanoparticle-modified SPE reached up to 325 ± 1 mg·g−1 in a 50 ± 0.5 μM Cs+ solution, with a distribution coefficient (Kd) of 580 ± 5 L·g−1 for Cs+ removal. The cesium concentration-dependent adsorption of PB nanoparticles was also demonstrated by fluorescence spectroscopy based on fluorescence quenching of PB nanoparticles as a function of cesium concentration using a standard fluorophore like fluorescein in a manner analogous to that previously reported for As(III).

16 January 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
Atul K. TiwariAtul K. Tiwari
Atul K. Tiwari
MGMunesh Kumar Gupta
Munesh Kumar Gupta
Hari Prakash YadavHari Prakash Yadav
Hari Prakash Yadav
Roger J. NarayanRoger J. Narayan
Roger J. Narayan
Prem Chandra PandeyPrem Chandra Pandey
Prem Chandra Pandey
Glutathione (GSH) and nickel (II) cation have an indispensable role in various physiological processes, including preventing the oxidative damage of cells and acting as a cofactor for lipid metabolic enzymes. An imbalance in the physiological level of these species may cause serious health complications. Therefore, sensitive and selective fluorescent probes for the detection of GSH and nickel (II) are of great interest for clinical as well as environmental monitoring. Herein, vancomycin-conjugated gold nanoparticles (PEI-AuNP@Van) were prepared and employed for the detection of GSH and nickel (II) based on a turn-on-off mechanism. The as-synthesized PEI-AuNP@Van was ~7.5 nm in size; it exhibited a spherical shape with face-centered cubic lattice symmetry. As compared to vancomycin unconjugated gold nanoparticles, GSH led to the turn-on state of PEI-AuNP@Van, while Ni2+ acted as a fluorescence quencher (turn-off) without the aggregation of nanoparticles. These phenomena strongly justify the active role of vancomycin conjugation for the detection of GSH and Ni2+. The turn-on-off kinetics was linearly proportional over the concentration range between 0.05–0.8 µM and 0.05–6.4 μM. The detection limits were 205.9 and 90.5 nM for GSH and Ni2+, respectively; these results are excellent in comparison to previous reports. This study demonstrates the active role of vancomycin conjugation for sensing of GSH and Ni2+ along with PEI-AuNP@Van as a promising nanoprobe.