Leadership style plays an important role in organization because a good leader can influence their followers to achieve the organization goals. However, each leader has their own characteristic and style in coordinate their subordinates. This study aims to explore how leadership styles affect job satisfaction and job performance. On-line questionnaire was adopted for data collection. There are 200 participants who work for the top-20 companies in Indonesia. The results indicated that the leadership style is significantly and positively correlated to job satisfaction and job performance. Furthermore, this study found that job satisfaction has a mediating effect on the relationship between leadership style and job performance.
A novel interleaved DC-DC buck converter is proposed to drive high-brightness light-emitting diodes (LEDs). The circuit configuration mainly consists of two buck converters, which are connected in parallel and use interleaved operation. Through interleaved operation, the power capability of the converter is doubled. Traditionally, two individual inductors are used in the two buck converters. The difference between conventional parallel-operated buck converters using two energy storage inductors and the proposed circuit is that the proposed circuit uses two small inductors and a coupled inductor that replace the two inductors of the buck converters. In this way, both buck converters can be designed to operate in discontinuous-current mode (DCM), even if the magnetizing inductance of the coupled inductor is large. Therefore, the freewheeling diodes can achieve zero-current switching off (ZCS). Applying the principle of conservation of magnetic flux, the magnetizing current is converted between the two windings of the coupled inductor. Because nearly constant magnetizing current continuously flows into the output, the output voltage ripple can be effectively reduced without the use of large-value electrolytic capacitors. In addition, each winding current can drop from positive to negative, and this reverse current can discharge the parasitic capacitor of the active switch to zero volts. In this way, the active switches can operate at zero-voltage switching on (ZVS), leading to low switching losses. A 180 W prototype LED driver was built and tested. Our experimental results show satisfactory performance.
True sine wave DC-to-AC inverters are becoming more and more important in solar power generation in order to raise the system’s efficiency. A high-quality true sine wave DC-to-AC inverter can be built with a robust intelligent control method. This robust intelligent control method is comprised of improved sliding mode reaching law (ISMRL) and particle swarm optimization (PSO)—catfish effect (CE). The sliding mode reaching law is robust and insensitive to parameter variations and external disturbances. However, it has infinite system-state convergence times and steady-state errors. In addition, solar panels are often affected by partial shading, causing the output power–voltage characteristic curve to be multi-peaked. Such a situation causes misjudgment of the maximum power point tracking with conventional algorithms, which can neither obtain the global extremes nor establish high conversion efficiency. Therefore, this paper proposes an ISMRL based on PSO-CE applied to the tracking of maximum power in the case of partial shading of a solar power generation system. The ISMRL guarantees quick terminable time convergence, making it well-suited for digital implementation. In this paper, PSO-CE is used to find the global best solution of ISMRL, rejecting steady-state errors, slow convergence, and premature trapping in local optimums. Simulation and experimental results are verified using digital implementation based on a Texas Instruments digital signal processor to produce more accurate and better tracking control of true sine wave DC-to-AC inverter-based solar power generation systems.
An H-bridge inverter with LC (inductor-capacitor) filter output allows the conversion of DC (direct current) power to AC (alternating current) power that has been used in a variety of applications, such as uninterruptible power supplies, AC motor drives, and renewable energy source systems. The fast finite-time sliding mode control (FFTSMC) features acceleration of the system state towards the equilibrium position as well as conserving insensitivity against internal parameter fluctuations as well as external load disturbances falling within the predetermined bounds. However, the FFTSMC would potentially witness chattering or steady-state errors as indefinite margins come to be exaggerated or underestimated. The chattering in the sliding mode control practice is oscillatory defective behavior. It induces inefficient operation, higher switching power losses in the transistor circuits, as well as saturated actuators, thus impairing the inverter’s output energy efficiency and raising harmonic distortion. Therefore, this paper presents the H-bridge inverter with LC filter output, which is controlled by a grey prediction fast finite-time sliding mode trajectory tracking. A more highly accurate grey prediction model based on the centered approximation methodology is deployed to vanish the chattering as well as steady-state errors. Taking into account the union of grey prediction and FFTSMC, a feedback-controlled H-bridge inverter with LC filter output allows attaining a highly efficient as well as quality sine-wave output voltage. The presented state-feedback control strategy is robust, less complex, attains more rapid convergence, and is highly accurate. The design process, computer simulation, as well as experimental results of the proposed state-feedback control strategy established that the H-bridge inverter with LC filter output has the capability to exhibit fast dynamic response time as well as good steady-state tracking behavior of the output voltage under step-loading changes and nonlinear loading conditions.
This paper presents a robust intelligent tracking-control technique which is subsequently applied to single-phase SPWM inverters. The proposed technique mixes advanced sliding mode control (ASMC) with grey-Markov model (GMM). The advanced sliding mode control allows the system state to converge quickly to the origin in a limited amount of time. Unfortunately, a chattering problem frequently occurs when the inverter suffers drastically from highly nonlinear or internal parameters changes. The large power losses and high harmonic distortion emerge in the inverter output. The role that the grey-Markov model plays is to reduce the chattering of the ASMC during system uncertainty overestimation, or to reduce the steady-state error caused by underestimation of system uncertainty. In conjunction with the GMM and the ASMC, fast transient response, low distortion of the sinusoidal output-voltage and reduced chattering can be obtained. Simulation results of the proposed single-phase SPWM inverter are carried out in MATLAB/Simulink. The experimental results have been validated through digital signal processors, enabling the single-phase SPWM inverter output to effectively improve the transient tracking speed and steady-state performance.
24 July 2026 in International Journal of Tourism Cities
1. The COVID-19 pandemic constituted an unprecedented disruption to global tourism, exposing the structural fragility of urban tourism systems and their sensitivity to mobility restrictions and ris...