Background: Monte Carlo (MC) simulations or measurements in anthropomorphic phantoms are recommended for estimating fetal dose in pregnant patients in radiotherapy. Among the many existing phantoms, there is no commercially available physical phantom representing the entire pregnant woman.Purpose: In this study, the development of a low‐cost, physical pregnant female phantom was demonstrated using commercially available materials. This phantom is based on the previously published computational phantom.Methods: Three tissue substitution materials (soft tissue, lung and bone tissue substitution) were developed. To verify Tena's substitution tissue materials, their radiation properties were assessed and compared to ICRP and ICRU materials using MC simulations in MV radiotherapy beams. Validation of the physical phantom was performed by comparing fetal doses obtained by measurements in the phantom with fetal doses obtained by MC simulations in computational phantom, during an MV photon breast radiotherapy treatment.Results: Materials used for building Tena phantom are matched to ICRU materials using physical density, radiation absorption properties and effective atomic number. MC simulations showed that percentage depth doses of Tena and ICRU material comply within 5% for soft and lung tissue, up to 25 cm depth. In the bone tissue, the discrepancy is higher, but again within 5% up to the depth of 5 cm. When the phantom was used for fetal dose measurements in MV photon breast radiotherapy, measured fetal doses complied with fetal doses calculated using MC simulation within 15%.Conclusions: Physical anthropomorphic phantom of pregnant patient can be manufactured using commercial materials and with low expenses. The files needed for 3D printing are now freely available. This enables further studies and comparison of numerical and physical experiments in diagnostic radiology or radiotherapy.
This study presents national surveys of patient exposure from nuclear medicine (NM) diagnostic procedures in 2010 and 2015 in the Republic of Croatia. The survey was performed according to the European Commission Dose DataMed (DDM) project methodology. 28 most frequent NM diagnostic procedures were identified. Data about frequencies of procedures and average administered activities of radioisotopes used in those procedures were collected. Average administered activities were converted to effective doses according to the dose conversion coefficients. Then the collective effective dose to the population and an effective dose per capita were calculated based on the number of the most frequent NM diagnostic procedures and the average effective dose per procedure. In 2010, 41200 NM diagnostic procedures led to 146.7 manSv collective effective dose to the population and in 2015, 42000 NM diagnostic procedures led to 146.8 manSv collective effective dose to the population. The frequencies of NM diagnostic procedures were 9.7 and 9.8 annually per 1000 population with 34.1 μSv and 34.2 μSv effective dose per capita for 2010 and 2015, respectively. The main contributors to the annual collective dose from NM in Croatia are examinations of the bone, heart, thyroid and PET/CT tumour diagnostic. Average administered activities have not changed considerably from 2010 to 2015. Nevertheless, within the frequency of some of the procedures, significant changes were found in five-year period. Frequencies, average administered activities and collective effective dose to the population from NM diagnostic procedures in Croatia are comparable to the values reported by other European surveys. Changes were found between 2010 and 2015 and we intend to perform this study periodically to identify possible trends, but also to raise awareness about the potential dose optimization.
A national audit of mammography equipment performance, image quality and dose has been conducted in Croatia. Film-processing parameters, optical density (OD), average glandular dose (AGD) to the standard breast, viewing conditions and image quality were examined using TOR(MAM) test object. Average film gradient ranged from 2.6 to 3.7, with a mean of 3.1. Tube voltage used for imaging of the standard 45 mm polymethylmethacrylate phantom ranged from 24 to 34 kV, and OD ranged from 0.75 to 1.94 with a mean of 1.26. AGD to the standard breast ranged from 0.4 to 2.3 mGy with a mean of 1.1 mGy. Besides clinical conditions, the authors have imaged the standard phantom in the referent conditions with 28 kV and OD as close as possible to 1.5. Then, AGD ranged from 0.5 to 2.6 mGy with a mean of 1.3 mGy. Image viewing conditions were generally unsatisfying with ambient light up to 500 lx and most of the viewing boxes with luminance between 1000 and 2000 cd per m(2). TOR(MAM) scoring of images taken in clinical and referent conditions was done by local radiologists in local image viewing conditions and by the referent radiologist in good image viewing conditions. Importance of OD and image viewing conditions for diagnostic information were analysed. The survey showed that the main problem in Croatia is the lack of written quality assurance/quality control (QA/QC) procedures. Consequently, equipment performance, image quality and dose are unstable and activities to improve image quality or to reduce the dose are not evidence-based. This survey also had an educational purpose, introducing in Croatia the QC based on European Commission Guidelines.
29 October 2018 in Journal of Radiological Protection
Objective : To investigate the relationship of the effective dose and dose area product (DAP) in dental cone beam computed tomography (CBCT) examinations and to propose conversion factors for estimation of effective doses of the patients using DAP. Dependence of organ doses on DAP was also investigated. Materials and Methods : Different exposure geometries in Cranex3Dx CBCT device were simulated using Monte Carlo simulation and computational anthropomorphic phantom. Then organ doses and effective dose for every exposure geometry was compared to DAP and analysed. Results : The effective dose in all simulated CBCT protocols and positions with 180° tube rotation ranged from 5 μ Sv for 50 × 50 mm 2 field of view (FOV) localised on one tooth using lowest resolution to 265 μ Sv for the largest FOV and highest resolution. In case of 360° tube rotation the effective dose ranges from 6 to 332 μ Sv for the same FOV sizes and positions as well as resolutions as in 180° tube rotation. Conclusions : Though the DAP introduces a large uncertainty in the risk measure in dental CBCT, it represents the dose and FOV size which are the most important scanning parameters affecting the dose. To decrease uncertainty in the risk measure, the effective dose has to be estimated for usual clinical positions of the FOV.