Background: Cranioplasty is a routine neurosurgery treatment used to correct cranial vault abnormalities. Utilization of 3D printing technology in the field of cranioplasty involving the reconstruction of cranial defects emerged as an advanced possibility of anatomical reshaping. The transformative impact of patient-specific 3D printed implants, focuses on their remarkable accuracy, customization capabilities, and enhanced biocompatibility. Methods: The precise adaptation of implants to patient-specific anatomies, even in complex cases we presented, result in improved aesthetic outcomes and reduced surgical complications. The ability to create highly customized implants addresses the functional aspects of cranial defects and considers the psychological impact on patients. Results: By combining technological innovation with personalized patient care, 3D printed cranioplasty emerges as a transformative avenue in cranial reconstruction, ultimately redefining the standards of success in neurosurgery. Conclusion: 3D printing allows an excellent cranioplasty cosmesis achieved at a reasonable price without sacrificing patient outcomes. Wider implementation of this strategy can lead to significant healthcare cost savings.
27 December 2023 in Journal of Applied Clinical Medical Physics
Background: Monte Carlo (MC) simulations or measurements in anthropomorphic phantoms are recommended for estimating fetal dose in pregnant patients in radiotherapy. Among the many existing phantoms, there is no commercially available physical phantom representing the entire pregnant woman.Purpose: In this study, the development of a low‐cost, physical pregnant female phantom was demonstrated using commercially available materials. This phantom is based on the previously published computational phantom.Methods: Three tissue substitution materials (soft tissue, lung and bone tissue substitution) were developed. To verify Tena's substitution tissue materials, their radiation properties were assessed and compared to ICRP and ICRU materials using MC simulations in MV radiotherapy beams. Validation of the physical phantom was performed by comparing fetal doses obtained by measurements in the phantom with fetal doses obtained by MC simulations in computational phantom, during an MV photon breast radiotherapy treatment.Results: Materials used for building Tena phantom are matched to ICRU materials using physical density, radiation absorption properties and effective atomic number. MC simulations showed that percentage depth doses of Tena and ICRU material comply within 5% for soft and lung tissue, up to 25 cm depth. In the bone tissue, the discrepancy is higher, but again within 5% up to the depth of 5 cm. When the phantom was used for fetal dose measurements in MV photon breast radiotherapy, measured fetal doses complied with fetal doses calculated using MC simulation within 15%.Conclusions: Physical anthropomorphic phantom of pregnant patient can be manufactured using commercial materials and with low expenses. The files needed for 3D printing are now freely available. This enables further studies and comparison of numerical and physical experiments in diagnostic radiology or radiotherapy.
Telemedicine is a rapid tool that reduces the time until treatment for patients, which is especially useful for neurosurgical trauma. The aim of our study was to evaluate the use of telemedicine in neurosurgery during the COVID-19 pandemic compared with the pre-pandemic era. We assessed the utilization of telemedicine at the Department of Neurosurgery at University Hospital Center Osijek in Croatia over a timespan of one year prior to the COVID-19 pandemic and the first year of the pandemic, starting with the date of first lockdown in Croatia. For each time period, the total number of consults and specific clinical inquiries were recorded and adequately grouped as well as comprehensive patient characteristics. There were 336 consults in the pre-pandemic period and 504 in the pandemic period. The number of trauma-related consults during COVID-19 measures was significantly higher than the pre-pandemic era (288 and 138, respectively, p < 0.0001). Neurosurgical trauma patients requiring consults in the pandemic period were significantly older than before the pandemic (64.9 ± 18.5 and 60.6 ± 19.1, respectively, p = 0.03). Significantly, the number of admissions to our center and urgent surgeries did not significantly differ between these periods. Telemedicine is a cost-effective tool in the neurosurgical evaluation of patients, especially for trauma. The COVID-19 pandemic accelerated telemedicine implementation and improved neurosurgical trauma treatments.
1 January 2024 in Nuclear Technology and Radiation Protection
This paper aims to describe the photon beam characteristics in terms of energy and angular distribution during breast megavoltage photon radiotherapy of pregnant patients. Photon beam characteristics are investigated at treatment volume (breast) and the position of the fetus in the Tena phantom using Monte Carlo simulation. Photon beam energy spectra are compared across various materials used as substitutes for constructing physical and computational phantoms. Mean energies calculated in substitute materials developed by our group and used to build the Tena phantom, differ up to 10 % from the calculated ones in ICRU reference tissue materials. It was found acceptable since this is less than the differences between ICRP and ICRU materials. Then, the photon beam characteristics are investigated in the anthropomorphic phantom, Tena. Photon beam mean energy in the fetal region of the phantom (out-of-field) is significantly lower (more than 1 MeV) than at the breast position (in-field). The angular distribution of the photon beam at the breast position predominantly shows a forward direction, whereas, at the fetus position, the distribution is more scattered. When selecting a detector, it is crucial to consider the differences in photon energy and angular distributions between in-field and out-of-field measurement points to reduce measurement uncertainties and ensure reliable data.
With advancements in computer systems, computer graphics and medical imaging technologies, clinicians strive for a personalised approach to patient treatment. Therefore, the production of personalised surgical guides is becoming standard. While proprietary software solutions for mandibular reconstruction planning exist, they are often not available due to their high costs. There are multiple alternative methods available, which utilise open-source technologies and free software, but they use advanced three-dimensional (3D) computer-aided design (CAD) concepts. The goal of this article is to provide end-users (surgeons, radiologists, or radiology technicians) with a tool that offers an intuitive interface and a simple workflow. The tool provides only the necessary methods offering a high degree of automation and abstracting the underlying 3D CAD concepts. This is accomplished by providing an add-on (written in Python) for a free and open-source software package Blender.
Background/Objectives: Blood vessel tortuosity can complicate endovascular procedures such as endovascular thrombectomy in acute ischemic stroke. This study aimed to assess the morphometric characteristics of carotid arteries and investigate the association between the tortuosity of the carotid arteries and the technical aspects of endovascular thrombectomy, patient demographics and clinical characteristics, and treatment outcome. Methods: This retrospective study included 84 patients with ischemic stroke treated by endovascular thrombectomy at the newly established thrombectomy-capable stroke center. The following data were collected from prethrombectomy computed tomography angiography: aortic arch type, type of carotid artery tortuosity, and tortuosity index (TI). The technical aspects of the procedure, as well as patient demographics, were collected from the radiological information system. Results: Time from arterial puncture to the first pass was significantly shorter in patients with a nontortuous carotid artery compared to a tortuous one (p = 0.006). There were no significant differences in the number of passes, total duration of the procedure, and the difference in National Institutes of Health Stroke Scale (NIHSS) score before and after the procedure regarding the form of tortuosity. Patients with hypertension had significantly higher tortuosity index values compared to those without hypertension (p = 0.008), and patients with a nontortuous carotid tree were significantly younger compared to those with all forms of tortuosity (p = 0.003). Conclusions: The majority of patients had tortuous carotid arteries, which were associated with older age and hypertension. A high index of tortuosity was associated with a longer time from arterial puncture to the first pass, but not to the treatment outcome. Preprocedural recognition of carotid artery tortuosity may aid in endovascular thrombectomy procedural planning.