In the current study, BaO was doped in Bi2O3-ZnO-B2O3-SLS glass to develop lead-free radiation shielding glasses and to solve the dark brown of bismuth glass. The melt-quenching method was utilized to fabricate (x) BaO (1 − x)[0.3 ZnO 0.2 Bi2O3 0.2 B2O3 0.3 SLS] (where x are 0.01, 0.02, 0.03, 0.04, and 0.05 mol) at 1200 °C. Soda lime silica glass waste (SLS), which is mostly composed of 74.1% SiO2, was used to obtain SiO2. The mass attenuation coefficient () was investigated utilizing X-ray fluorescence (XRF) at 16.61, 17.74, 21.17, and 25.27 keV and narrow beam geometry at 59.54, 662, and 1333 keV. Moreover, the other parameters related to gamma ray shielding properties such as half-value layer (HVL), mean free path (MFP), and effective atomic number () were computed depending on values. The results indicated that HVL and MFP decreased, whereas increased with an increase in BaO concentration. According to these results, it can be concluded that BaO doped in Bi2O3-ZnO-B2O3-SLS glass is a nontoxic, transparent to visible light, and a good shielding material against radiation.
22 April 2024 in Nuclear Engineering and Technology
The current study aims to enhance the efficiency of lead-free glass as a shielding material against radiation, solve the problem of the dark brown of bismuth glass, and reduce the accumulation of waste glass disposed in landfills by using soda-lime-silica SLS glass waste. The melt-quenching method was utilized to fabricate (WO [(BiO) (ZnO) (BO) (SLS)] at 1200 °C, where x = (0, 0.01, 0.02, 0.03, 0.04, and 0.05 mol). Soda lime silica SLS glass waste, which is mostly composed of 74.1 % SiO, was used to obtain SiO. Radiation Attenuation parameters were investigated using narrow-beam geometry and X-ray fluorescence (XRF). Furthermore, the parameters related to radiation shielding were calculated. The results showed that when WO concentration was increased, the half-value layer was reduced, whereas the increased. It could be concluded that WBiBZn-SLS glass is a good shielding material against radiation, nontoxic, and transparent to visible light.
29 April 2024 in Journal of Applied Sciences and Environmental Management
Thermoluminescence dosimeters (TLDs) are widely used in radiation dosimetry due to their excellent properties, such as high sensitivity, small size, and ability to measure low doses of radiation. This review focuses on the structural properties of TLD materials, as well as their preparation, application, and adaptability. The review covers the various types of TLD materials, crystal structure, and properties, including energy response and fading characteristics. The different methods used to prepare TLD materials, such as solid-state synthesis, sol-gel synthesis, and solution growth methods, are discussed in detail. The review also includes a detailed discussion of the various applications of TLDs, including medical, environmental, and industrial radiation dosimetry. Extensive information on TLD is reviewed, and the TL characteristics that have a noticeable impact on the TL dosimetry potential for human and other purpose utilisation, such as mineral, oil, and gas resource investigation, can be done using natural and artificial TL signals. Information on TL measurement process requirements and the TL characteristics that have a noticeable impact on a compound TL dosimetry potential are also addressed. Finally, the review concludes by highlighting the adaptability of TLD materials to different dosimetry applications and their potential use in the future.