Jorge Bonet-Jara

Mr. Jorge Bonet-Jara

Universitat Politècnica València
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JBJorge Bonet-Jara
Jorge Bonet-Jara
AQAlfredo QUIJANO-LOPEZ
Alfredo QUIJANO-LOPEZ
DANIEL MORINIGO-SOTELODANIEL MORINIGO-SOTELO
DANIEL MORINIGO-SOTELO
JPJoan Pons-Llinares
Joan Pons-Llinares
Sensorless speed estimation has been extensively studied for its use in control schemes. Nevertheless, it is also a key step when applying Motor Current Signature Analysis to induction motor diagnosis: accurate speed estimation is vital to locate fault harmonics, and prevent false positives and false negatives, as shown at the beginning of the paper through a real industrial case. Unfortunately, existing sensorless speed estimation techniques either do not provide enough precision for this purpose or have limited applicability. Currently, this is preventing Industry 4.0 from having a precise and automatic system to monitor the motor condition. Despite its importance, there is no research published reviewing this topic. To fill this gap, this paper investigates, from both theoretical background and an industrial application perspective, the reasons behind these problems. Therefore, the families of sensorless speed estimation techniques, mainly conceived for sensorless control, are here reviewed and thoroughly analyzed from the perspective of their use for diagnosis. Moreover, the algorithms implemented in the two leading commercial diagnostic devices are analyzed using real examples from a database of industrial measurements belonging to 79 induction motors. The analysis and discussion through the paper are synthesized to summarize the lacks and weaknesses of the industry application of these methods, which helps to highlight the open problems, challenges and research prospects, showing the direction in which research efforts have to be made to solve this important problem.

28 December 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JBJorge Bonet-Jara
Jorge Bonet-Jara
JPJoan Pons-Llinares
Joan Pons-Llinares
Konstantinos N. GyftakisKonstantinos N. Gyftakis
Konstantinos N. Gyftakis
Early detection of interturn faults is one of the most important issues in electrical machines, as the fault severity evolves very fast to a catastrophic failure due to the high thermal stress. However, as this article shows, in submersible induction motors for deep-well pumps, it evolves slower. These motors are highly water-cooled, which significantly reduces the thermal stress caused by the fault, increasing the possibility of early detection. Among fault detection methods, only those based on line current/voltage measurements can be used, as motors are at great depths. This article investigates the principal slot harmonics as reliable indicators for early detection of interturn faults in this application. To this end, a comprehensive analysis is conducted using finite-element analysis where the behavior of these harmonics is studied under different fault severities, both alone and coexisting with other asymmetries, such as unbalanced voltages, eccentricity, or rotor faults. The findings are used to develop a reliable diagnostic scheme based on the monitoring of the most fault-sensitive harmonics along with the voltage and current unbalance indexes. Finally, the scheme is applied, for the first time, in the context of continuous monitoring of a 230-HP induction motor showing its efficacy.

12 April 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
JBJorge Bonet-Jara
Jorge Bonet-Jara
DANIEL MORINIGO-SOTELODANIEL MORINIGO-SOTELO
DANIEL MORINIGO-SOTELO
Oscar Duque-PerezOscar Duque-Perez
Oscar Duque-Perez
LSLuis Serrano-Iribarnegaray
Luis Serrano-Iribarnegaray
JPJoan Pons-Llinares
Joan Pons-Llinares
Wear of end ring is to date an unreported and uninvestigated failure that very frequently takes place in deep-well submersible motor pumps. This article first analyses the particularities of these induction motors, especially their unusual rotor manufacturing process. Failure mechanism related to the end-ring wear is described, showing several examples of damaged rotors in a motor repair shop. Then, the difficulties of its diagnosis through conventional rotor asymmetry indicators are described, caused by the subtlety of this fault and the very easy appearance of false negatives. The end-ring wear detection through a multicomponent approach is researched through simulation, laboratory results, and the diagnosis of two-field motors showing that new fault alarm levels need to be defined. To perform this last step and for the first time in the technical literature, two induction motors working in a deep borehole have been continuously monitored (one measure every six operating hours) for almost one year.

9 November 2022 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
JBJorge Bonet-Jara
Jorge Bonet-Jara
JPJoan Pons-Llinares
Joan Pons-Llinares
Efficiency estimation and diagnosis via MCSA require precise knowledge of speed. In an industrial environment, speed must be obtained with a non-invasive, automatic and general method. Recent studies have shown that Sensorless Speed Estimation techniques based on detecting Rotational Frequency Sideband Harmonics (RFSHs) or Rotor Slot Harmonics (RSHs) are best suited to these purposes. RFSHs-based methods are easier to apply as they only depend on the number of poles. RSHs-based are much more accurate due to their wider bandwidth. Yet, their use is not trivial as they require to identify the RSHs family, assign to each RSH its order of the current harmonic ( $\nu$ ) and determine the number of rotor slots ( $R$ ), a rarely known parameter. This paper ends with this trade-off between accuracy and applicability by proposing a novel RSHs-based technique that, for the first time in technical literature, eliminates the need to estimate the number of rotor slots and provides a reliable and automatic procedure to locate the RSHs family and determine their $\nu$ indices. Finally, the method is validated under all types of conditions and motor designs, by simulations, lab tests and with 105 industrial motors, highlighting its high accuracy (errors below 0.05 rpm), and applicability.

11 June 2024 in IEEE Transactions on Industry Applications
Verified
Journal Article
Open access
JBJorge Bonet-Jara
Jorge Bonet-Jara
JPJoan Pons-Llinares
Joan Pons-Llinares
DANIEL MORINIGO-SOTELODANIEL MORINIGO-SOTELO
DANIEL MORINIGO-SOTELO
Konstantinos N. GyftakisKonstantinos N. Gyftakis
Konstantinos N. Gyftakis
Stator inter-turn faults (ITFs) are one of the most challenging to detect: in their early stage they are too subtle, and on the other hand they rapidly evolve into a catastrophic failure. In turn, its detection is of prime importance, since it is one of the main reasons for motor failures in medium and high-voltage induction motors (IMs). This paper discovers and fully characterizes a family of new ITFs-related harmonics not described before in previous literature. For that purpose, a deep finite element analysis of three motors with different characteristics is conducted, under different fault stages. The appearance mechanism of these new harmonics is physically described, the formula for their time-frequency trajectories is derived and the flux sensor design is optimized for their detection. Finally, the existence of these harmonics is proven in a 0.75 kW IM through a novel methodology that emulates the electromagnetic effects of an ITF but without endangering the stator's windings.

29 February 2024 in IEEE Transactions on Industry Applications
Verified
Journal Article
Open access
JBJorge Bonet-Jara
Jorge Bonet-Jara
VFVanesa Fernandez-Cavero
Vanesa Fernandez-Cavero
Francisco Vedreño SantosFrancisco Vedreño Santos
Francisco Vedreño Santos
DANIEL MORINIGO-SOTELODANIEL MORINIGO-SOTELO
DANIEL MORINIGO-SOTELO
JPJoan Pons-Llinares
Joan Pons-Llinares
Induction motors work under steady-state in many applications. Nevertheless, in some cases they experience periodic load fluctuations, which generate constant frequency harmonics close to variable frequency bar breakage harmonics. In these cases, time-frequency (t-f) transforms are better suited than steady-state analysis since the fault harmonic frequencies change in time. Even if the healthy and faulty frequencies do not overlap in the spectrum, if the speed is unknown, it is difficult to distinguish the constant frequency healthy harmonic from the variable frequency bar breakage harmonic. On the other hand, transient techniques present in technical literature are not precise enough to deal with both the changing frequency of the bar breakage harmonic and a close constant frequency (as the one generated by most of the periodic load fluctuations). To achieve reliable results under these challenging situations, a very precise time-frequency transform must be used, enabling to simultaneously draw the constant and variable frequencies, even if they are very close in the t-f plane. The Dragon-Transform is here proposed to address the problem. It is shown through simulation and experimental results, how it enables to very accurately plot up to five faulty harmonics evolutions, distinguishing at the same time the constant frequency of the load oscillation, traced as a very thin horizontal line. Precision is so high that even the oscillations caused by ripple effect can be observed for the first time in technical literature, enhancing the reliability of the diagnosis performed, and opening the path for a true solution of the problem.