João Pequeno

Mr. João Pequeno

MARE—Marine and Environmental Sciences Centre, Lisbon, Lisboa, Portugal
+1
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2021 in Frontiers in Environmental Science
Verified
Journal Article
Open access
PDF file
João PequenoJoão Pequeno
João Pequeno
JAJoana Antunes
Joana Antunes
VDViren Dhimmer
Viren Dhimmer
FBFilipa Bessa
Filipa Bessa
PSPaula Sobral
Paula Sobral
Microplastics (MP) have been confirmed as emerging pollutants in the marine environment due to their ubiquity, bioavailability, persistence and potential toxicity. This study contributes with valuable data regarding the abundance and characteristics of the MP found in five species collected from Portugal. The mussel Mytilus galloprovincialis (n = 140) was collected from the Tagus estuary and Porto Covo coastal area, the peppery furrow shell Scrobicularia plana (n = 140) and the polychaete Marphysa sanguinea (n = 30) both from the Sado estuary, and Trachurus trachurus (n = 82) and Scomber colias (n = 82) fished off Figueira da Foz and Sesimbra. Soft tissues of all individuals were digested using a KOH (10%) solution, which allowed the extraction of MP. All studied species presented MP. In a total of 502 MP observed from all samples, 80% were fibers and 20% were fragments, with a size range of 73 μm–4,680 μm and blue was the most common color recorded (46%). The frequency of occurrence of MP was higher in T. trachurus (70%) and lowest in M. sanguinea (17%). MP abundance ranged from 0.30 ± 0.63 MP. ind−1 in S. plana, to 2.46 ± 4.12 MP. ind−1 in S. colias. No significant correlation was found between the individual biometric parameters and total MP, fibers and fragments ingested by each species. The FTIR analysis revealed that polyester and polyethylene were the most common polymers present. These results can be used as a reference for future studies regarding the use of indicator species for monitoring MP pollution in the coast of Portugal.

16 February 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
BSBárbara Andreia Sá
Bárbara Andreia Sá
Joana PaisJoana Pais
Joana Pais
Joana AntunesJoana Antunes
Joana Antunes
João PequenoJoão Pequeno
João Pequeno
Ana PiresAna Pires
Ana Pires
PSPaula Sobral
Paula Sobral
The majority of microplastics (MP) found in the marine environment have land-based sources and rivers are known as carriers of these particles to the ocean. This work is the first to study MP in the Lis River Basin and coastal shoreline (total nine sampling sites) and the potential relationship with inputs from 105 companies/units. We report the seasonal abundance, typology, colour, size, and polymer distribution of MP in surface water and sediment. To the collected samples, a digestion protocol was applied, followed by filtration. For sediment, an MP density separation was performed prior to filtration. MP were mostly fibres (0.02 to 1111.11 items.m−3 in water and 10.66 to 1609.64 items.kg−1 in sediment) and fragments (0.02 to 2311.11 items.m−3 in water and 10.66 to 501.01 items.kg−1 in sediment). The most frequent colours were transparent and blue, and MP were mostly smaller than 1 mm in water and 2 mm in sediment samples. The most abundant polymers in water were polyethylene (37%), polyacrylate (18%) and polystyrene (18%), and in sediment, polyethylene terephthalate (29%) and polyacrylate (23%). Population density, plastic processing companies and meteorological factors were found to be associated with seasonal MP abundance and distribution patterns in the Lis River Basin.

18 April 2025 in Water
Verified
Journal Article
Open access
PDF file
JGJosé Gonçalves
José Gonçalves
João PequenoJoão Pequeno
João Pequeno
IDIsrael Diaz
Israel Diaz
Davor KržišnikDavor Kržišnik
Davor Kržišnik
JŽJure Žigon
Jure Žigon
TKTom Koritnik
Tom Koritnik
Global water scarcity and antimicrobial resistance (AMR) represent two escalating crises that urgently demand integrated and effective solutions. While wastewater reuse is increasingly promoted as a strategy to alleviate water scarcity, conventional treatment processes often fail to eliminate persistent contaminants and antibiotic-resistant microorganisms. Cold plasma (CP), a non-thermal advanced oxidation process, has demonstrated the strong potential to simultaneously inactivate pathogens and degrade micropollutants. CP generates a diverse mix of reactive oxygen and nitrogen species (ROS and RNS), as well as UV photons and charged particles, capable of breaking down complex contaminants and inducing irreversible damage to microbial cells. Laboratory studies have reported bacterial log reductions ranging from 1 to >8–9 log10, with Gram-negative species such as E. coli and Pseudomonas aeruginosa showing higher susceptibility than Gram-positive bacteria. The inactivation of endospores and mixed-species biofilms has also been achieved under optimized CP conditions. Viral inactivation studies, including MS2 bacteriophage and norovirus surrogates, have demonstrated reductions >99.99%, with exposure times as short as 0.12 s. CP has further shown the capacity to degrade antibiotic residues such as ciprofloxacin and sulfamethoxazole by >90% and to reduce ARGs (e.g., bla, sul, and tet) in hospital wastewater. This perspective critically examines the mechanisms and current applications of CP in wastewater treatment, identifies the operational and scalability challenges, and outlines a research agenda for integrating CP into future water reuse frameworks targeting AMR mitigation and sustainable water management.

8 April 2026 in Pollutants
Verified
Journal Article
Open access
PDF file
JGJosé Gonçalves
José Gonçalves
João PequenoJoão Pequeno
João Pequeno
Davor KržišnikDavor Kržišnik
Davor Kržišnik
PSPaula Sobral
Paula Sobral
Joana AntunesJoana Antunes
Joana Antunes
Nanoplastics (NPs, <100 nm) have emerged as nano-scale contaminants with superior mobility and biological barrier-crossing capacity, yet risk assessment fails due to unstandardized analytical methods and a lack of realistic exposure data. This perspective proposes an “Exposome–Microbiome–Immune” (EMI) framework as a One Health paradigm to integrate detection, toxicokinetics, and systemic effects. We prioritize the following actions: (i) validated nano–Fourier transform infrared spectroscopy (nanoFTIR) and surface-enhanced Raman spectroscopy (SERS) for environmental/human monitoring; (ii) multigenerational studies in zebrafish and organoids; (iii) longitudinal cohorts for biomonitoring. Without shifting from descriptive reviews to systems toxicology, NP risk will remain underestimated.

15 October 2026
Verified
Book Chapter
Open access
PDF file
JGJosé Gonçalves
José Gonçalves
TKTom Koritnik
Tom Koritnik
João PequenoJoão Pequeno
João Pequeno
Joana AntunesJoana Antunes
Joana Antunes
IDIsrael Diaz
Israel Diaz
Davor KržišnikDavor Kržišnik
Davor Kržišnik
Cold plasma (CP) is emerging as a promising advanced oxidation technology for decentralized water disinfection, offering broad-spectrum antimicrobial potential, low energy demand and minimal chemical residuals. In the context of circular and resilient urban water systems, a key challenge is to move beyond millilitre-scale laboratory reactors towards scalable units that can be integrated into building and district water loops. This work presents the conception and proof-of-concept evaluation of a dielectric barrier discharge (DBD) cold-plasma reactor equipped with a microbubble diffuser, specifically designed to enhance gas-liquid interaction and enable modular upscaling for the built environment. The prototype allows treatment of 500 mL water volumes, representing a substantial increase compared with conventional benchtop configurations, and is validated using Escherichia coli as a representative fecal indicator organism. The reactor ensures stable discharge and reproducible antimicrobial performance, achieving multi-log reductions in colony-forming units within treatment times compatible with on-site or point-of-use sanitation. Design choices are discussed in terms of footprint, energy efficiency and potential integration in greywater reuse systems and high-risk building effluents. The reactor concept provides a flexible platform for future assessment of clinically relevant pathogens, antibiotic residues and microplastics-associated contaminants, contributing to safer water reuse streams and to reshaping the built environment through sustainability and circularity.