Kasun Piyumal

Dr. Kasun Piyumal

University of Kelaniya
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019
Verified
Conference Paper
Closed access
Kasun PiyumalKasun Piyumal
Kasun Piyumal
ARA L A K Ranaweera
A L A K Ranaweera
SKS R D Kalingamudali
S R D Kalingamudali
NKNihal Kularatna
Nihal Kularatna
Usually a battery is used as the energy storage device in typical standalone solar photovoltaic (PV) systems. It is charged by a solar charge controller. The charging efficiency of the system depends on the efficiency of the DC-DC converter of solar charge controller. However, a considerable amount of usable energy is wasted during the charging process. In this work, a method is proposed to utilize this wasted energy and thereby to enhance the charging efficiency. In the case of an empty capacitor being charged by an external source, it stores only half of the energy delivered by the source as compared to that of an electrochemical battery. Therefore, it wastes 50% of useful energy. A portion of this wasted energy can be collected and utilized if a useful resistive load is connected in series to this capacitor charging loop. In this study, a DC-DC converter and battery bank is connected as the useful resistive load in the capacitor charging loop. A supercapacitor (SC) bank is used replacing the conventional capacitor. Therefore, total energy loss in capacitor charging loop can be minimized by storing energy in both battery bank and SC bank. This concept is introduced into a typical PV system for reducing its energy losses. Experimental results show an enhancement in charging efficiency when this new method is employed. The energy stored in the SC bank could be used for driving loads with required electronics.

8 February 2025 in Physchem
Verified
Journal Article
Open access
PDF file
HWHiruni Eranga Wijesooriya
Hiruni Eranga Wijesooriya
JSJ. A. Seneviratne
J. A. Seneviratne
KJKMDC Jayathilaka
KMDC Jayathilaka
RFRoshan Fernando
Roshan Fernando
Kasun PiyumalKasun Piyumal
Kasun Piyumal
RWR. P. Wijesundera
R. P. Wijesundera
Dissolved oxygen (DO) is a crucial parameter in water quality monitoring because it directly affects the health of aquatic ecosystems. This study explored electrodeposited Cu2O thin-film semiconductors for DO sensing. Cu2O was chosen for its low cost, eco-friendliness, and non-toxic nature. Cu2O films were electrodeposited on titanium (Ti) substrates using an acetate bath (0.1 M sodium acetate and 0.01 M cupric acetate) at −200 mV versus Ag/AgCl for 30 min, with a bath temperature of 55 °C, stirred at 50 rpm. The bath pH was systematically adjusted from 5.8 to 6.8 in 0.2 steps using NaOH and Acetic acid. A range of analyses including synchrotron X-ray diffraction (SXRD), scanning electron microscopy (SEM), surface wettability, capacitance–voltage (C-V), Raman spectroscopy, Fourier-transform infrared (FTIR) spectrum, and Electrochemical Impedance Spectroscopy (EIS) was performed to assess their properties and sensing performance. The results showed that Cu2O films deposited at pH 6.4 exhibited optimal performance for DO sensing, with a strong linear response, marking this pH, deposition time, and temperature as ideal for creating effective DO sensors. This study introduces a novel, cost-effective approach to dissolved oxygen sensing using electrodeposited n-Cu2O thin-film semiconductors, marking the first application of this material in such sensors and showcasing its potential for scalable and environmentally sustainable sensing technologies.

24 April 2022 in ECS Transactions
Verified
Journal Article
Closed access
Kasun PiyumalKasun Piyumal
Kasun Piyumal
ARAruna Ranaweera
Aruna Ranaweera
SKSudath Kalingamudali
Sudath Kalingamudali
NKNihal Kularatna
Nihal Kularatna
An off-grid photovoltaic (PV) system's PV array is connected with a charge controller as the first power conversion stage. The average efficiency of the power stage of charge controllers is around 90%. Supercapacitor (SC) battery hybrid PV system is a novel PV system that utilizes some of the wasted energy of a typical system and enhances the system's efficiency up to 98%. However, the feasibility of maximum power point tracking (MPPT) for this system is yet to be validated. This paper presents a comparative study to adapt MPPT for the proposed system consisting of a series-connected SC bank with PV array and step-down DC-DC converter. The step-down converter is used as the impedance matching network. Different solar irradiance profiles were emulated to check the feasibility and efficiency of MPPT. Experimentally, it was shown that the typical MPPT could be adapted to the proposed PV system with very high MPPT efficiency.

1 December 2018
Verified
Conference Paper
Closed access
Kasun PiyumalKasun Piyumal
Kasun Piyumal
ARA L A K Ranaweera
A L A K Ranaweera
SKS R D Kalingamudali
S R D Kalingamudali
NKNihal Kularatna
Nihal Kularatna
Typical standalone solar photovoltaic (PV) systems use battery bank as the energy storage device. The battery bank is charged by using a solar charge controller connected to a solar array. For similar PV systems, charging efficiency mostly depends on the efficiency of DC-DC converter available inside the charge controller. However, considerable amount of usable energy will be wasted during the charging process. In this work, a method is proposed to utilize this wasted energy while enhancing the end to end efficiency of standalone PV systems. When an empty capacitor is charged by an external source, it stores only a half of the energy delivered by the source as compared to the case of an electrochemical battery. As a result, 50% of useful energy is lost in the charging loop of a capacitor. If a useful resistive load is connected to this loop, some amount of energy can be utilized by doing a beneficial work. In this study, a DC-DC converter and battery bank has been chosen as the useful load in the capacitor charging loop, and a supercapacitor (SC) bank is used replacing the conventional capacitor. Therefore, total energy loss can be minimized by storing energy in both battery and SC bank. The energy stored in the SCs could be used for driving loads with required electronics. Consequently, it leads to an improvement of end to end efficiency of the PV system.

4 October 2021 in Electronics
Verified
Journal Article
Open access
PDF file
Kasun PiyumalKasun Piyumal
Kasun Piyumal
Aruna Kumara RanaweeraAruna Kumara Ranaweera
Aruna Kumara Ranaweera
SKSudath Deshapriya Kaligamudali
Sudath Deshapriya Kaligamudali
Nihal KularatnaNihal Kularatna
Nihal Kularatna
In photovoltaic (PV) systems, maximum power point (MPP) is tracked by matching the load impedance to the internal impedance of the PV array by adjusting the duty cycle of the associated DC-DC converter. Scientists are trying to improve the efficiency of these converters by improving the performance of the power stage, while limited attention is given to finding alternative methods. This article describes a novel supercapacitor (SC) assisted technique to enhance the efficiency of a PV system without modifying the power stage of the charge controller. The proposed system is an SC—battery hybrid PV system where an SC bank is coupled in series with a PV array to enhance the overall system efficiency. Developed prototype of the proposed system with SC assisted loss circumvention embedded with a DC microgrid application detailed in the article showed that the average efficiency of the PV system is increased by 8%. This article further describes the theoretical and experimental investigation of the impedance matching technique for the proposed PV system, explaining how to adapt typical impedance matching for maximum power transfer.

1 December 2020
Verified
Conference Paper
Closed access
LJL D P S Jayasekara
L D P S Jayasekara
Kasun PiyumalKasun Piyumal
Kasun Piyumal
ARA L A K Ranaweera
A L A K Ranaweera
SKS R D Kalingamudali
S R D Kalingamudali
This study was primarily focused on presenting a novel method to enhance the efficiency of Supercapacitor Assisted Low Dropout (SCALDO) regulators. The main objective was to study SCALDO regulators under a specifically controlled condition where supply voltage is less than twice of the required minimum voltage for Low Dropout (LDO) regulators. Furthermore, design modifications to the switching controlling algorithm were performed to optimize number of capacitors with respect to the supply voltage in order to enhance the efficiency of SCALDO regulators. It was theoretically proven that the efficiency decline can be successfully reduced by varying the number of capacitors connected, according to the supply voltage and the minimum input voltages. The theoretical efficiency calculated for the proposed SCALDO technique falls within 81.5% - 88% range, which is well above the previously reported values. This was verified experimentally with the prototype developed using 2.7 V, 10 F supercapacitors, 5-3.3 V LDO.