Banafsheh Khalesi

Dr. Banafsheh Khalesi

London South Bank University, London, City of London, UK
+1
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
Behnaz SohaniBehnaz Sohani
Behnaz Sohani
Banafsheh KhalesiBanafsheh Khalesi
Banafsheh Khalesi
Navid GhavamiNavid Ghavami
Navid Ghavami
Mohammad GhavamiMohammad Ghavami
Mohammad Ghavami
SDSandra Dudley
Sandra Dudley
GTGianluigi Tiberi
Gianluigi Tiberi

26 October 2020 in IEEE Antennas and Wireless Propagation Letters
Verified
Journal Article
Closed access
Banafsheh KhalesiBanafsheh Khalesi
Banafsheh Khalesi
Behnaz SohaniBehnaz Sohani
Behnaz Sohani
Navid GhavamiNavid Ghavami
Navid Ghavami
Mohammad GhavamiMohammad Ghavami
Mohammad Ghavami
Sandra DudleySandra Dudley
Sandra Dudley
Gianluigi TiberiGianluigi Tiberi
Gianluigi Tiberi
In this letter, a phantom validation of a low complexity microwave imaging device operating in free space in the 1-6.5 GHz frequency band is presented. The device, initially constructed for breast cancer detection, measures the scattered signals in a multi-bistatic fashion and employs an imaging procedure based on Huygens principle. Detection has been achieved in both bone fracture lesion and bone marrow lesion scenarios using the superimposition of five doublet transmitting positions, after applying the rotation subtraction artefact removal method. A resolution of 5 mm and a signal to clutter ratio (3.35 in linear scale) are achieved confirming the advantage of employing multiple transmitting positions on increased detection capability.

28 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Behnaz SohaniBehnaz Sohani
Behnaz Sohani
James PuttockJames Puttock
James Puttock
Banafsheh KhalesiBanafsheh Khalesi
Banafsheh Khalesi
Navid GhavamiNavid Ghavami
Navid Ghavami
Mohammad GhavamiMohammad Ghavami
Mohammad Ghavami
Gianluigi TiberiGianluigi Tiberi
Gianluigi Tiberi
In this paper, we present an investigation of different artefact removal methods for ultra-wideband Microwave Imaging (MWI) to evaluate and quantify current methods in a real environment through measurements using an MWI device. The MWI device measures the scattered signals in a multi-bistatic fashion and employs an imaging procedure based on Huygens principle. A simple two-layered phantom mimicking human head tissue is realised, applying a cylindrically shaped inclusion to emulate brain haemorrhage. Detection has been successfully achieved using the superimposition of five transmitter triplet positions, after applying different artefact removal methods, with the inclusion positioned at 0°, 90°, 180°, and 270°. The different artifact removal methods have been proposed for comparison to improve the stroke detection process. To provide a valid comparison between these methods, image quantification metrics are presented. An “ideal/reference” image is used to compare the artefact removal methods. Moreover, the quantification of artefact removal procedures through measurements using MWI device is performed.

9 December 2019 in Electronics
Verified
Journal Article
Open access
PDF file
Banafsheh KhalesiBanafsheh Khalesi
Banafsheh Khalesi
Behnaz SohaniBehnaz Sohani
Behnaz Sohani
Navid GhavamiNavid Ghavami
Navid Ghavami
Mohammad GhavamiMohammad Ghavami
Mohammad Ghavami
Sandra DudleySandra Dudley
Sandra Dudley
Gianluigi TiberiGianluigi Tiberi
Gianluigi Tiberi
This paper demonstrates the outcomes of a feasibility study of a microwave imaging procedure based on the Huygens principle for bone lesion detection. This study has been performed using a dedicated phantom and validated through measurements in the frequency range of 1–3 GHz using one receiving and one transmitting antenna in free space. Specifically, a multilayered bone phantom, which is comprised of cortical bone and bone marrow layers, was fabricated. The identification of the lesion’s presence in different bone layers was performed on images that were derived after processing through Huygens’ principle, the S21 signals measured inside an anechoic chamber in multi-bistatic fashion. The quantification of the obtained images was carried out by introducing parameters such as the resolution and signal-to-clutter ratio (SCR). The impact of different frequencies and bandwidths (in the 1–3 GHz range) in lesion detection was investigated. The findings showed that the frequency range of 1.5–2.5 GHz offered the best resolution (1.1 cm) and SCR (2.22 on a linear scale). Subtraction between S21 obtained using two slightly displaced transmitting positions was employed to remove the artefacts; the best artefact removal was obtained when the spatial displacement was approximately of the same magnitude as the dimension of the lesion.

5 July 2022 in Electronics
Verified
Journal Article
Open access
PDF file
Banafsheh KhalesiBanafsheh Khalesi
Banafsheh Khalesi
BKBilal Khalid
Bilal Khalid
Navid GhavamiNavid Ghavami
Navid Ghavami
GRGiovanni Raspa
Giovanni Raspa
Mohammad GhavamiMohammad Ghavami
Mohammad Ghavami
Gianluigi TiberiGianluigi Tiberi
Gianluigi Tiberi
In this work, a feasibility study for lung lesion detection through microwave imaging based on Huygens’ principle (HP) has been performed using multilayer oval shaped phantoms mimicking human torso having a cylindrically shaped inclusion simulating lung lesion. First, validation of the proposed imaging method has been performed through phantom experiments using a dedicated realistic human torso model inside an anechoic chamber, employing a frequency range of 1–5 GHz. Subsequently, the miniaturized torso phantom validation (using both single and double inclusion scenarios) has been accomplished using a microwave imaging (MWI) device, which operates in free space using two antennas in multi-bistatic configuration. The identification of the target’s presence in the lung layer has been achieved on the obtained images after applying both of the following artifact removal procedures: (i) the “rotation subtraction” method using two adjacent transmitting antenna positions, and (ii) the “ideal” artifact removal procedure utilizing the difference between received signals from unhealthy and healthy scenarios. In addition, a quantitative analysis of the obtained images was executed based on the definition of signal to clutter ratio (SCR). The obtained results verify that HP can be utilized successfully to discover the presence and location of the inclusion in the lung-mimicking phantom, achieving an SCR of 9.88 dB.

2 November 2024 in BMJ Open
Verified
Journal Article
Open access
PDF file
Daniel Alvarez Sánchez-BayuelaDaniel Alvarez Sánchez-Bayuela
Daniel Alvarez Sánchez-Bayuela
JMJuan Fernández Martín
Juan Fernández Martín
Gianluigi TiberiGianluigi Tiberi
Gianluigi Tiberi
Navid GhavamiNavid Ghavami
Navid Ghavami
RGRubén Giovanetti González
Rubén Giovanetti González
CCCristina Romero Castellano
Cristina Romero Castellano
Introduction Microwave imaging presents several potential advantages including its non-ionising and harmless nature. This open, multicentric, interventional, prospective, non-randomised trial aims to validate MammoWave’s artificial intelligence (AI)-based classification algorithm, leveraging microwave imaging, to achieve a sensitivity exceeding 75% and a specificity exceeding 90% in breast screening. Methods and analysis 10 000 volunteers undergoing regular mammographic breast cancer screening will be recruited across 9 European centres and invited to participate in the clinical study, involving MammoWave testing on both breasts. MammoWave results will be checked against the reference standard, to be intended as the output of conventional breast examination path (with histological confirmation of cancer cases) with 2 years follow-up. Anonymised clinical and MammoWave’s results, including microwave images, associated features and a label provided by the AI-based classification algorithm, will be collected and stored in a dedicated electronic case report form. The prospective study will involve a comparative analysis between the output of the conventional breast examination path (control intervention) and the labels provided by MammoWave’s AI system (experimental intervention). These labels will categorise breasts into two groups: breast With Suspicious Finding, indicating the presence of a suspicious lesion or No Suspicious Finding, indicating the absence of a lesion or the presence of a low-suspicion lesion. This trial aims to provide evidence regarding the novel MammoWave’s AI system for detecting breast cancer in asymptomatic populations during screening. Ethics and dissemination This study was approved by the Research Ethics Committee of the Liguria Region (CET), Italy (CET-Liguria: 524/2023—DB id 13399), the Research Ethics Committee of Complejo Hospitalario de Toledo (CEIC), Spain (CEIC-1094), the National Ethics Committee for Clinical Research (CEIC), Portugal (CEIC-2311KC814), the Bioethical Committee of Pomeranian Medical University in Szczecin, Poland (KB-006/23/2024) and the Zurich Cantonal Ethics Commission, Switzerland (BASEC 2023-D0101). The findings of this study will be disseminated through academic and scientific conferences as well as peer-reviewed journals. Trial registration number NCT06291896.