Behnaz Sohani

Dr. Behnaz Sohani

Loughborough University, Loughborough, Leicestershire, UK
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
Behnaz SohaniBehnaz Sohani
Behnaz Sohani
Banafsheh KhalesiBanafsheh Khalesi
Banafsheh Khalesi
Navid GhavamiNavid Ghavami
Navid Ghavami
Mohammad GhavamiMohammad Ghavami
Mohammad Ghavami
SDSandra Dudley
Sandra Dudley
GTGianluigi Tiberi
Gianluigi Tiberi

23 March 2023 in International Journal of Multiphase Flow
Verified
Journal Article
Open access
Aliyu M. AliyuAliyu M. Aliyu
Aliyu M. Aliyu
RCRaihan Choudhury
Raihan Choudhury
Behnaz SohaniBehnaz Sohani
Behnaz Sohani
JAJohn Atanbori
John Atanbori
JRJoseph X.F. Ribeiro
Joseph X.F. Ribeiro
Professor Rakesh MishraProfessor Rakesh Mishra
Professor Rakesh Mishra

26 October 2020 in IEEE Antennas and Wireless Propagation Letters
Verified
Journal Article
Closed access
Banafsheh KhalesiBanafsheh Khalesi
Banafsheh Khalesi
Behnaz SohaniBehnaz Sohani
Behnaz Sohani
Navid GhavamiNavid Ghavami
Navid Ghavami
Mohammad GhavamiMohammad Ghavami
Mohammad Ghavami
Sandra DudleySandra Dudley
Sandra Dudley
Gianluigi TiberiGianluigi Tiberi
Gianluigi Tiberi
In this letter, a phantom validation of a low complexity microwave imaging device operating in free space in the 1-6.5 GHz frequency band is presented. The device, initially constructed for breast cancer detection, measures the scattered signals in a multi-bistatic fashion and employs an imaging procedure based on Huygens principle. Detection has been achieved in both bone fracture lesion and bone marrow lesion scenarios using the superimposition of five doublet transmitting positions, after applying the rotation subtraction artefact removal method. A resolution of 5 mm and a signal to clutter ratio (3.35 in linear scale) are achieved confirming the advantage of employing multiple transmitting positions on increased detection capability.

1 June 2019
Verified
Conference Paper
Closed access
Behnaz SohaniBehnaz Sohani
Behnaz Sohani
GTGianluigi Tiberi
Gianluigi Tiberi
Navid GhavamiNavid Ghavami
Navid Ghavami
Mohammad GhavamiMohammad Ghavami
Mohammad Ghavami
SDSandra Dudley
Sandra Dudley
ARAmir Rahmani
Amir Rahmani
This paper provides initial results on the efficacy of Huygens Principle (HP) microwave imaging for haemorrhagic stroke detection. This is done using both simulations and measurements in an anechoic chamber. Microstrip antennas operating between 1 and 2 GHz have been designed, constructed and used for imaging a human head model in Computer Simulation Technology (CST) software. A 3D model consisting of human head tissues of Ella is employed in simulation. An emulated haemorrhagic stroke with the dielectric properties equivalent to the blood has been inserted in Ella. Moreover, a 3-layered head-mimicking phantom containing an inclusion has been constructed. Frequency-domain measurements have been performed in an anechoic chamber using a Vector Network Analyser arrangement to obtain the transfer function (S 21 ) between two antennas. Both simulations and measurements show that HP based technique may be used for haemorrhagic stroke detection. Among linear scattering techniques, the HP based technique allows to detect dielectrics inhomogeneities in frequency domain. HP can also be used if the antennas and phantom are in free space, i.e., no coupling liquid is required.

28 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Behnaz SohaniBehnaz Sohani
Behnaz Sohani
James PuttockJames Puttock
James Puttock
Banafsheh KhalesiBanafsheh Khalesi
Banafsheh Khalesi
Navid GhavamiNavid Ghavami
Navid Ghavami
Mohammad GhavamiMohammad Ghavami
Mohammad Ghavami
Gianluigi TiberiGianluigi Tiberi
Gianluigi Tiberi
In this paper, we present an investigation of different artefact removal methods for ultra-wideband Microwave Imaging (MWI) to evaluate and quantify current methods in a real environment through measurements using an MWI device. The MWI device measures the scattered signals in a multi-bistatic fashion and employs an imaging procedure based on Huygens principle. A simple two-layered phantom mimicking human head tissue is realised, applying a cylindrically shaped inclusion to emulate brain haemorrhage. Detection has been successfully achieved using the superimposition of five transmitter triplet positions, after applying different artefact removal methods, with the inclusion positioned at 0°, 90°, 180°, and 270°. The different artifact removal methods have been proposed for comparison to improve the stroke detection process. To provide a valid comparison between these methods, image quantification metrics are presented. An “ideal/reference” image is used to compare the artefact removal methods. Moreover, the quantification of artefact removal procedures through measurements using MWI device is performed.

9 December 2019 in Electronics
Verified
Journal Article
Open access
PDF file
Banafsheh KhalesiBanafsheh Khalesi
Banafsheh Khalesi
Behnaz SohaniBehnaz Sohani
Behnaz Sohani
Navid GhavamiNavid Ghavami
Navid Ghavami
Mohammad GhavamiMohammad Ghavami
Mohammad Ghavami
Sandra DudleySandra Dudley
Sandra Dudley
Gianluigi TiberiGianluigi Tiberi
Gianluigi Tiberi
This paper demonstrates the outcomes of a feasibility study of a microwave imaging procedure based on the Huygens principle for bone lesion detection. This study has been performed using a dedicated phantom and validated through measurements in the frequency range of 1–3 GHz using one receiving and one transmitting antenna in free space. Specifically, a multilayered bone phantom, which is comprised of cortical bone and bone marrow layers, was fabricated. The identification of the lesion’s presence in different bone layers was performed on images that were derived after processing through Huygens’ principle, the S21 signals measured inside an anechoic chamber in multi-bistatic fashion. The quantification of the obtained images was carried out by introducing parameters such as the resolution and signal-to-clutter ratio (SCR). The impact of different frequencies and bandwidths (in the 1–3 GHz range) in lesion detection was investigated. The findings showed that the frequency range of 1.5–2.5 GHz offered the best resolution (1.1 cm) and SCR (2.22 on a linear scale). Subtraction between S21 obtained using two slightly displaced transmitting positions was employed to remove the artefacts; the best artefact removal was obtained when the spatial displacement was approximately of the same magnitude as the dimension of the lesion.