This paper reports a statistical analysis of a database archiving information on the strengths of the materials in existing Italian bridges having pre- and post-tensioned concrete beams. Data were collected in anonymous form by analyzing a stock of about 170 bridges built between 1960 and 2000 and located in several Italian regions. To date, the database refers to steel reinforcing bars, concrete, and prestressing steel, whose strengths were gathered from design nominal values, acceptance certificates, and in situ test results, all derived by consulting the available documents for each examined bridge. At first, this paper describes how the available data were collected. Then, the results of a statistical analysis are presented and commented on. Moreover, goodness-of-fit tests are carried out to verify the assumption validity of a normal distribution for steel reinforcing bars and prestressing steel, and a log-normal distribution for concrete. The database represents a valuable resource for researchers and practitioners for the assessment of existing bridges. It may be applied for the use of prior knowledge within a framework where Bayesian methods are included for reducing uncertainties. The database provides essential information on the strengths of the materials to be used for a simulated design and/or for verification in the case of limited knowledge. Goodness-of-fit tests make the collected information very useful, even if probabilistic methods are applied.
This paper deals with the seismic retrofit of existing frames by means of external passive dissipative systems. Available in different configurations, these systems allow high flexibility in controlling the structural behaviour and are characterized by some feasibility advantages with respect to dissipative devices installed within existing frames. In particular, this study analyzes and compares the performances of two external solutions using linear viscous dampers. The first is based on the coupling of the building with an external fixed‐based steel braced frame by means of dampers placed horizontally at the floor levels. The second is an innovative one, based on coupling the building with a “dissipative tower,” which is a steel braced frame hinged at the foundation level, and activating the dampers through its rocking motion. The effectiveness of the two solutions is evaluated and compared by considering a benchmark existing reinforced concrete building, employing a stochastic dynamic approach, under the assumption of linear elastic behaviour for the seismic performance evaluation. This allows efficiently estimating the statistics of many response parameters of interest for the performance assessment and thus carrying out extensive parametric analyses for different properties of the external systems. The study results provide useful information regarding the design and the relative efficiency of the proposed retrofit solutions.
8 November 2023 in Structural Control and Health Monitoring
The λ-factors for stiffness and damping of rubber bearings should be experimentally assessed during the qualification process or deduced from tests performed on material specimens. Moreover, the λ-factors suggested in the informative annexes of EN 15129 and of EC8-part 2 can be also used as reference values. However, they are derived from outdated experimental campaigns and do not refer to all the sources of variability. In this paper, a statistical analysis on a significant set of rubber compounds, certified according to EN 15129 from different suppliers, is carried out to assess the current variability of the dynamic properties of such compounds. Different sources of variability may be identified by distinguishing between behavioural and environmental effects. For elastomeric bearings, especially high-damping rubber (HDR) ones, the main behavioural effects are strain amplitude, strain rate dependence, and cyclic degradation, whereas the environmental effects are due to temperature variation and ageing. All these sources of variability have been analysed in this paper. The results of the statistical analysis have been used to propose a new set of λ-factors for all the source of variability studied. Such new values have been compared with the ones suggested by the codes when available. The main inconsistencies found have been highlighted and commented in this paper. Finally, some considerations about the influence of such variability on the structural response of base-isolated structures have been drawn by focusing on both the isolation system and the superstructure.
1 January 2025 in Structural Control and Health Monitoring
Displacements are among the most important engineering response parameters to be monitored during shake‐table testing, with experiments playing a key role in studying the seismic behavior of structures. However, their accurate measurement is not a trivial task when using contact sensors. Computer vision is an attractive alternative for monitoring absolute and relative displacements, and this study presents a new configuration to fully exploit its potential. The proposed solution combines internal and external video cameras. The former is installed on the roof and points downwards to simultaneously acquire the displacements of targets located throughout the height of the building. The latter was installed outside the shake‐table platen and tracked the roof displacements to provide redundant measures for control and noise compensation. In this way, the movements of the buildings can be reconstructed with high robustness and precision using a limited number of video cameras. The proposed configuration was applied for the first time during shake‐table testing of a full‐scale six‐story building on the outdoor shake table at the University of California, San Diego. The measurements obtained up to strong dynamic inputs showed the capacity of the proposed approach in real‐world environmental conditions and were used for a critical comparison with conventional contact sensors.
In recent years, innovative Non-Destructive Testing (NDT) techniques, applicable for the assessment of existing civil structures, have become available for in situ analysis on Reinforced Concrete (RC) and masonry structures, but they are still not established for regular inspections, especially after seismic events. The damage assessment of RC buildings after seismic events is a very relevant issue in Italy, where most of the structures built in the last 50 years are RC structures. Furthermore, there is also a growing interest in being able to monitor structural health aspects by storing them on the building’s digital twin. For these reasons, it is necessary to develop an affordable and ready-to-use NDT procedure that provides more accurate indications on the real state of damage of reinforced concrete buildings after seismic events and to integrate these data into an interoperable digital twin for automated, optimized building performance monitoring, management, and preventive maintenance. To this end, a case study was conducted on a building in the Marche region in Italy, damaged by the 2016 earthquake. Non-destructive tests were performed and inserted into the LIS platform for the creation of a digital twin of the building. This platform seamlessly manages, visualizes, and analyzes the collected data and integrates various sensor nodes deployed throughout the building. The paper also presents a methodology to simplify the work of the test operator and make the entire process of knowledge of the building faster and more sustainable through a QR-code interface.