Marco Cavaliere

Dr. Marco Cavaliere

Tyndall National Institute, Cork, Ireland
+1
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MCMarco Cavaliere
Marco Cavaliere
OMOisin McVeigh
Oisin McVeigh
HJHerman Alexander Jaeger
Herman Alexander Jaeger
SHStephen Hinds
Stephen Hinds
KOKilian O'DOnoghue
Kilian O'DOnoghue
PCPadraig Cantillon-Murphy
Padraig Cantillon-Murphy
As the importance and prevalence of electromagnetic tracking in medical and industrial applications increases, the need for customized sensor design has escalated. This work focuses on AC-based electromagnetic tracking systems where off-the-shelf inductive sensors may not be optimal for many medical instruments or tracking applications. We present a repeatable approach for the design, optimisation and implementation of air-core and ferrite-core inductive sensors suitable for AC-based electromagnetic tracking. Coil-based sensors were designed and tested to investigate the effect of the usual coil parameters such as turn count, geometry and core material on sensor tracking accuracy and precision. Our methodologies were experimentally validated using the Anser EMT system which enabled rapid experimental deployment. Experimental performance is reported compared to off-the-shelf sensors. Static tracking errors of less than 2mm were achieved and close correlation with theoretical design sensitivity and precision was observed. This work may represent a valuable tool in the design of bespoke sensors for electromagnetic tracking where customize sensitivity and form factor are critical.

11 May 2023 in IEEE Transactions on Magnetics
Verified
Journal Article
Open access
MCMarco Cavaliere
Marco Cavaliere
DCDaragh Crowley
Daragh Crowley
HJHerman Alexander Jaeger
Herman Alexander Jaeger
KOKilian O’dOnoghue
Kilian O’dOnoghue
PCPádraig Cantillon-Murphy
Pádraig Cantillon-Murphy
Electromagnetic tracking (EMT) of surgical tools is used for image-guided navigation in minimally invasive interventions. Calibration of the tracker position and orientation is a fundamental task to correct systematic errors. This article explores the effect of metallic distortion on the open hardware Anser EMT system and describes a newly developed approach for volume calibration of the magnetic field model. The technique is also applied to effectively map the field in the presence of magnetic shields that can be used to reduce electromagnetic distortions passively. Unlike calibration techniques commonly found in literature, which aim to correct the tracking position error, our method can reconstruct an analytical magnetic field model starting from a reduced amount of scattered data. This way, a faster convergence of the solver algorithm is obtained, and EMT position and orientation errors are inherently corrected. The new modelling technique was applied to generate a new, undistorted magnetic field model for Anser EMT, to demonstrate the effectiveness of passive shielding, and to compensate for the distortion introduced by a commercial fluoroscopy C-arm. Furthermore, the concept of a real-time distortion compensation technique is expressed based on the modelling method presented in this article. For all the experiments, sub-millimeter errors were obtained after calibration, which may meet the needs of most endoscopic and surgical navigation tasks.

16 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MCMarco Cavaliere
Marco Cavaliere
HJHerman Alexander Jaeger
Herman Alexander Jaeger
O Kilian O'Donoghue
Kilian O'Donoghue
PCPádraig Cantillon-Murphy
Pádraig Cantillon-Murphy
Electromagnetic tracking is a safe, reliable, and cost-effective method to track medical instruments in image-guided surgical navigation. However, patient motion and magnetic field distortions heavily impact the accuracy of tracked position and orientation. The use of redundant magnetic sensors can help to map and mitigate for patient movements and magnetic field distortions within the tracking region. We propose a planar inductive sensor design, printed on PCB and embedded into medical patches. The main advantage is the high repeatability and the cost benefit of using mass PCB manufacturing processes. The article presents new operative formulas for electromagnetic tracking of planar coils on the centimetre scale. The full magnetic analytical model is based on the mutual inductance between coils which can be approximated as being composed by straight conductive filaments. The full model is used to perform accurate system simulations and to assess the accuracy of faster simplified magnetic models, which are necessary to achieve real-time tracking in medical applications.

23 May 2022 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
MCMarco Cavaliere
Marco Cavaliere
PCPádraig Cantillon-Murphy
Pádraig Cantillon-Murphy
Purpose: Hybrid navigation is a promising technique which combines the benefits of optical or electromagnetic tracking (EMT) and fluoroscopy imaging. Unfortunately, the fluoroscopy system is a source of metallic distortion for the EMT system. In this work, we present a new method for intraoperative calibration and real-time compensation of dynamic field distortions. The method was tested in the presence of a fluoroscopy C-arm, and sub-millimetre errors were obtained after distortion correction. Methods: A hybrid navigation scenario was created by combining the open-source electromagnetic tracking system Anser EMT and a commercial fluoroscopy C-arm. The electromagnetic field generator was placed directly on top of the X-ray collimator, which introduced significant field distortion. Magnetic sensors were placed at known positions to capture the magnetic distortion, and virtual magnetic dipole sources were used to model the distortion magnetic field. The accuracy of the compensated EMT model was tested on a grid of test points. Results: Error reduction was demonstrated from 12.01 to 0.35 mm and from 25.03 to 0.49 mm, for horizontal and vertical sensor orientations, respectively, over a volume of 16 × 16 × 6 cm. It is proposed that such sub-millimetre tracking errors meet the needs of most endoscopic navigation tasks. Conclusions: We describe a method to model a magnetic field in real time, based on redundant electromagnetic field measurements, and we apply it to compensate for the distortion introduced by a fluoroscopy C-arm. The main limitation of the approach is the requirement for a high number of sensors, with possible occlusion of the operative space. Solutions might come from miniaturisation and wireless sensing.

27 July 2023 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
MCMarco Cavaliere
Marco Cavaliere
PCPádraig Cantillon-Murphy
Pádraig Cantillon-Murphy
Purpose: Electromagnetic tracking (EMT) accuracy is affected by the presence of surrounding metallic materials. In this work, we propose measuring the magnetic field's variation due to distortion at a witness position to localise the instrument causing distortion based on a pre-trained model and without additional sensors attached to it. Methods: Two experiments were performed to demonstrate possible applications of the technique proposed. In the first case, the distortion introduced by an ultrasound (US) probe was characterised and subsequently used to track the probe position on a line. In the second application, the measurement was used to estimate the distance of an interventional fluoroscopy C-arm machine and apply the correct compensation model. Results: Tracking of the US probe using the proposed method was demonstrated with millimetric accuracy. The distortion created by the C-arm caused errors in the order of centimetres, which were reduced to 1.52 mm RMS after compensation. Conclusions: The distortion profile associated with medical equipment was pre-characterised and used in applications such as object tracking and error compensation map selection. In the current study, the movement was limited to one degree of freedom (1 DOF) and simple analytical functions were used to model the magnetic distortion. Future work will explore advanced AI models to extend the method to 6 DOF tracking using multiple witness sensors.

19 September 2024 in IEEE Sensors Journal
Verified
Journal Article
Open access
DCDaragh Crowley
Daragh Crowley
MCMarco Cavaliere
Marco Cavaliere
EHEoin Higgins
Eoin Higgins
CPCharu Pande
Charu Pande
HJHerman Alexander Jaeger
Herman Alexander Jaeger
PCPádraig Cantillon-Murphy
Pádraig Cantillon-Murphy
Electromagnetic tracking is essential in surgical navigation without line of sight and to reduce use of harmful radiation-based imaging. The inductive sensors used in current electromagnetic tracking systems are small, often less than a millimetre in diameter, but the need for a wired connection from the sensor to the control unit can cause obstructions and complicate the surgical field. This work introduces a novel wireless method of tracking electromagnetic sensors with immediate applications intended to streamline surgical workflows. Wireless electromagnetic 6 degree-of-freedom sensor nodes were designed and manufactured with an intended use as a patient mounted registration device. The battery-powered prototype device was shown to have a position and orientation trueness of 0.84 mm and 0.7∘, respectively, over a tracking volume of 40 × 40 × 35 cm. The sensor node performs analog and digital signal processing and uses Bluetooth low energy to transmit the sensor data at a 25 Hz refresh rate. The Bluetooth-based wireless electromagnetic sensors nodes developed in this work have comparable performance to standard wired sensors and were tested in both a static volume characterization and a dynamic ex-vivo lung model. The work in this paper is based on the open-source Anser electromagnetic tracking system, although the approach can be generalised to any tracking system. Wireless electromagnetic tracking offers the potential to introduce computer-assisted navigation in surgical procedures where wired sensors were previously infeasible.