maria isabel isabel relimpio Relimpio

Dr. maria isabel isabel relimpio Relimpio

Opthalmologist
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2023 in Clinical & Experimental Ophthalmology
Verified
Journal Article
Open access
MPManuel Pérez‐Pérez
Manuel Pérez‐Pérez
AAAlessandro Agostino
Alessandro Agostino
CSCarmen García de Sola‐Llamas
Carmen García de Sola‐Llamas
MRMichael Ruvolo
Michael Ruvolo
AVAngel Vilches-Arenas
Angel Vilches-Arenas
JRJuan J. Ríos‐Martín
Juan J. Ríos‐Martín
Background: Uveal melanoma (UM) is the eye's most common primary malignancy and there are no effective therapies for disseminated disease. It is important to try to know the patient's prognosis. The aim of this study was to reflect genetic variants, studied using NGS, of a series of 69 cases of UM and its correlation with histopathology and clinical progression.Methods: We performed targeted NGS using a 519‐gene panel.Results: There were selected 28 different mutated genes, showing a total of 231 genetic variants that affected the function of the protein. The most common secondary mutations occurred in SF3B1 (in 26%), followed by BAP1 (in 23%), LRP1B (22%) and FGFR4 (20%). BAP1 mutation was associated with a greater likelihood of metastases and with greater presence of epithelioid cells. LRP1B was also associated with presence of epithelioid cells SF3B1 mutation was significantly associated with a spindle morphology. We found variants in the RAD51B, TOP2A, PTPRD, TSC2, DHX9, PDK1 and MTOR that have not been previously reported in consulted databases. The presence of a mutation in: CHEK2, DHX9 and PDK1 was associated with metastases.Conclusions: BAP1 is the most solid biomarker of a poor prognosis in UM and mutations can be detected using NGS. SF3B1 is associated with the spindle cell subtype of UM, which gives it probably a favourable prognostic value. Our study suggests that mutations in DHX9 and PDK1 can have prognostic value. These potential biomarkers are related to the PI3K/AKT/mTOR pathway and makes them candidates for developing new directed therapies.

15 March 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MRmaria isabel isabel relimpio Relimpio
maria isabel isabel relimpio Relimpio
AGAntonio Manuel Garrido-Hermosilla
Antonio Manuel Garrido-Hermosilla
FEFrancisco Espejo
Francisco Espejo
MGMaria Gessa-Sorroche
Maria Gessa-Sorroche
LCLourdes Coca
Lourdes Coca
JLJose Antonio Terron Leon
Jose Antonio Terron Leon
Currently, brachytherapy is the most commonly used therapeutic approach for uveal melanomas. Surgical resection by means of endoresection or exoresection is an alternative approach. The present report recounts our experience over 15 years in the treatment of uveal melanoma using a combined approach of resection surgery with brachytherapy. This is a single-center observational retrospective cohort study in which we describe clinical outcomes, complications and survival in 35 cases of melanoma of the iris or the ciliary body after a combination of surgery and brachytherapy or brachytherapy alone. Local treatment of the tumor was successful in all cases with surgery and brachytherapy. The most frequent complications were scleromalacia, bullous keratopathy, retinal toxicity, cataracts, hypotonia, and photophobia. There were three cases of recurrence, all of which were found in the group of patients who had received brachytherapy alone, and in one case we had to perform a secondary enucleation due to tumor growth after brachytherapy. At present, only one patient has died during follow-up due to liver metastases six years after the start of treatment. In carefully selected patients, this approach can be effective and safe, as long as a close follow-up is carried out after surgery.

29 November 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
JUJesús David Urbano-Gámez
Jesús David Urbano-Gámez
LSLourdes Valdes Sanchez
Lourdes Valdes Sanchez
CACarmen Aracil
Carmen Aracil
BCBerta de la Cerda
Berta de la Cerda
FPFrancisco Perdigones
Francisco Perdigones
Jose Manuel B91794131Jose Manuel B91794131
Jose Manuel B91794131
Printed circuit board (PCB) technology is well known, reliable, and low-cost, and its application to biomedicine, which implies the integration of microfluidics and electronics, has led to Lab-on-PCB. However, the biocompatibility of the involved materials has to be examined if they are in contact with biological elements. In this paper, the solder mask (PSR-2000 CD02G/CA-25 CD01, Taiyo Ink (Suzhou) Co., Ltd., Suzhou, China) of a commercial PCB has been studied for retinal cultures. For this purpose, retinal explants have been cultured over this substrate, both on open and closed systems, with successful results. Cell viability data shows that the solder mask has no cytotoxic effect on the culture allowing the application of PCB as the substrate of customized microelectrode arrays (MEAs). Finally, a comparative study of the biocompatibility of the 3D printer Uniz zSG amber resin has also been carried out.

27 August 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
AGAntonio Manuel Garrido-Hermosilla
Antonio Manuel Garrido-Hermosilla
IMIrene Martinez-Alberquilla
Irene Martinez-Alberquilla
MDMaría Concepción Díaz-Ruiz
María Concepción Díaz-Ruiz
RCRaquel Monge Carmona
Raquel Monge Carmona
MMMariola Méndez-Muros
Mariola Méndez-Muros
EREnrique Rodríguez-De-La-Rúa-Franch
Enrique Rodríguez-De-La-Rúa-Franch
Objectives: To assess the overall mental health of enucleated or eviscerated patients after high-density porous polyethylene OCULFIT implantation and external prosthesis over a 1-year follow-up. Methods: Patients with an indication of enucleation or evisceration with OCULFIT implantation were included in a prospective study. The patients completed four questionnaires regarding mental health at three different visits (baseline, 3–6 months, and 9–12 months post-surgery). The questionnaires used were the following: SF-12 for multidimensional health-related quality of life (scale 0–100); Rosemberg self-esteem scale (scale 0–40); Patients Health Questionnaire-4 (PHQ-4) (scale 0–6); and a Lifetime Major Depression and Anhedonia questionnaire (categorised in groups with/without symptoms). Results: A total of 33 patients (16 enucleations and 17 eviscerations) were included in the study. The physical domain of the SF-12 questionnaire did not change between visits, but the mental domain significantly improved from the baseline to the last visit (41.71 ± 12.72 vs. 46.80 ± 10.68, p = 0.04). The number of patients with high, moderate, and low self-esteem (Rosemberg scale) was similar between the baseline and the last visit. The depression and anxiety scores of the PHQ-4 were not significantly different among visits. The number of patients with no symptoms (depression or anhedonia) improved from the baseline (42.2%) throughout the follow-up (66.7% at the last visit). Conclusions: OCULFIT orbital implant and external prosthesis placement maintained and/or improved the quality of life related to mental health in eviscerated and enucleated eyes. The number of patients with no symptoms improved from the baseline throughout the follow-up. The patients’ self-esteem was already high before implantation and remained stable over the follow-up.

27 November 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
AGAntonio Manuel Garrido-Hermosilla
Antonio Manuel Garrido-Hermosilla
IMIrene Martinez-Alberquilla
Irene Martinez-Alberquilla
MDMaría Concepción Díaz-Ruiz
María Concepción Díaz-Ruiz
RCRaquel Monge Carmona
Raquel Monge Carmona
MMMariola Méndez-Muros
Mariola Méndez-Muros
EREnrique Rodríguez-De-La-Rúa-Franch
Enrique Rodríguez-De-La-Rúa-Franch
OBJECTIVES: To describe our experience with a new high-density porous polyethylene orbital implant post-enucleation and evisceration and comment on their performance and safety. METHODS: Patients with an indication of enucleation or evisceration with orbital implantation were included in a prospective study. All patients were implanted with OCULFIT orbital implants (AJL Ophthalmic S.A.) and followed up over 12 months. Anatomical and functional parameters, motility, and aesthetic appearance were evaluated. Patient satisfaction on a scale of 0 (very bad) to 5 (excellent), complications and success rates were reported. RESULTS: Overall, 16 enucleated and 17 eviscerated eyes were analyzed. Orbital implant motility was good for 93.8% and 100% of enucleated and eviscerated patients, respectively. No shortened fornixes were found after external prosthesis placement, and palpebral fissure, orbital volume, and lower eyelid laxity were symmetric with the contralateral eye for the vast majority. The aesthetic appearance was good for 87.5% and 100% of enucleated and eviscerated patients at the last visit with no differences between groups. Excellent satisfaction was reported for 100% and 94.1% of enucleated and eviscerated patients. Anatomical and functional success rates were 78.8% and 81.8%, respectively. No exposure, infection or complications related to surgery were reported during the follow-up. CONCLUSIONS: After 1 year of follow-up, OCULFIT orbital implants provide excellent patient satisfaction and performance in terms of motility and symmetry with the contralateral eye after external prosthesis placement with no complications related to the surgical procedure. No differences between enucleated and eviscerated eyes were found, and aesthetic results were remarkable for both groups. Conclusions should be interpreted with caution due to the small sample size.

9 December 2015 in Ophthalmologica
Verified
Journal Article
Closed access
PDF file
MRmaria isabel isabel relimpio Relimpio
maria isabel isabel relimpio Relimpio
MSMaría Gessa Sorroche
María Gessa Sorroche
AGAntonio Manuel Garrido-Hermosilla
Antonio Manuel Garrido-Hermosilla
TGTeresa Laborda Guirao
Teresa Laborda Guirao
FAFrancisco Espejo Arjona
Francisco Espejo Arjona
EFEnrique Rodríguez de la Rúa Franch
Enrique Rodríguez de la Rúa Franch
Purpose: The aim is to describe the main characteristics of an anterior/posterior segment surgery and how to resolve intraoperative complications. Setting/Venue: The anterior and posterior segment surgical video was created at the Department of Ophthalmology, Virgin Macarena University Hospital, Seville, Spain. Methods: We present the case of a male with Stevens-Johnson syndrome and severe limbal deficiency who needed a Boston type 1 keratoprosthesis, reaching a visual acuity of 0.4 (0.05 before surgery). In the course of follow-up, he developed corneal melting with perforation, immune vitritis, and a large epimacular membrane. We decided to perform a 23-gauge vitrectomy associated with keratoprosthesis exchange. As a consequence of inappropriate anesthesia, the patient woke up during the surgery, provoking a retinal tear besides a choroidal detachment. These damages needed endolaser photocoagulation as well as silicone oil tamponade, forcing us to postpone the exchange. An intravitreal dexamethasone implant was also injected. Two months later, the silicone oil was removed, and the Boston keratoprosthesis was replaced by a new type 1 model with a titanium back plate, which likely improves biocompatibility and retention and may reduce complications such as retroprosthetic membranes and stromal corneal melts. Results: Good anatomical results were achieved, and visual acuity slightly improved to 0.2. Conclusions: Combined anterior and posterior segment surgery represents a great challenge that can improve not only visual acuity but also quality of life in patients with severe diseases such as Stevens-Johnson syndrome.