A simple scheme to implement class AB low-voltage fully differential amplifiers that do not require an output common-mode feedback network (CMFN) is introduced. It has a rail to rail output signal swing and high rejection of common-mode input signals. It operates in strong inversion with ±300 mV supplies in a 180 nm CMOS process. It uses an auxiliary amplifier that minimizes supply requirements by setting the op-amp input terminals very close to one of the rails and also serves as a common-mode feedback network to generate complementary output signals. The scheme is verified with simulation results of an amplifier that consumes 25 µW, has a gain-bandwidth product (GBW) of 16.1 MHz, slew rate (SR) of 8.4 V/µs, the small signal figure of merit (FOMSS) of 6.49 MHz*pF/µW, the large signal figure of merit (FOMLS) of 3.39 V/µs*pF/µW, and current efficiency (CE) of 2.03 in strong inversion, with a 10 pF load capacitance.
18 July 2023 in IEEE Transactions on Biomedical Circuits and Systems
This paper presents an electrocardiogram (ECG) delineation and arrhythmia heartbeat detection system using a novel second-order level-crossing sampling analog to digital converter (ADC) for real-time data compression and feature extraction. The proposed system consists of the front-end integrated circuit of the data converter, the delineation algorithm, and the arrhythmia detection algorithm. Compared with conventional level-sampling ADCs, the proposed circuit updates tracking thresholds using linear extrapolation, which forms a second-order level-crossing sampling ADC that has sloped sampling levels. The computing is done digitally and is implemented by modifying the digital control logic of a conventional Successive-approximation-register (SAR) ADC. The system separates the sampling and quantization processes and only selects the turning points in the input waveform for quantization. The output of the proposed data converter consists of both the digital value of the selected sampling points and the timestamp between the selected sampling points. The main advantages are data savings for the data converter and the following digital signal processing or communication circuits, which are ideal for low-power sensors. The test chip was fabricated using a 180nm CMOS process. When sensing sparse signals such as ECG signals the proposed ADC achieves a compression factor of 8.33. The delineation algorithm uses a triangle filter method to locate the fiducial points and measures the intervals, slopes, and morphology of the QRS complex and the P/T waves. Those extracted features are then used in the arrhythmia heartbeat detection algorithm to identify Premature Ventricular Contraction (PVC). The overall performance of the system is evaluated using the MIT-BIH database and the QT database, which is also compared with the recently reported systems. The accuracy, sensitivity, specificity, PPV, and F1 score are 97.3%, 89.6%, 97.8%, 73.3%, and 0.81 for detecting PVC.
This paper presents a slope level-crossing sampling analog-to-digital converter that selects key sampling points for quantization in real time during sensing. It only performs quantization for the turning points in the input analog waveform and provides quantization results of the selected sampling points and timestamps between the selected sampling points. When the input analog signal is sparse, the proposed method reduces digital output data throughput. The processing unit generates a dynamic prediction of the input signal as well as an upper threshold and a lower threshold to form a tracking window. A comparator compares the input signal with the upper and lower threshold to determine if the prediction is successful. Quantization is performed only on unsuccessful predicted sampling points, which are considered key sampling points. A counter records timestamps between the unsuccessful predictions which are the selected key sampling points. The processing unit also includes a neighbor amplitude filter and a slope filter to further reduce the number of sampling points and data throughput when the input signal is associated with high-frequency low-amplitude noise and high-amplitude low-frequency baseline wandering. Reconstruction of the analog signal can be achieved using linear interpolation or polynomial interpolation. The system has been implemented and tested using off-the-shelf components. The simulation and experimental results show that the proposed system can reduce the data throughput and achieve a data compression ratio of 7.1 compared to a conventional successive approximation register analog-to-digital converter with a 10-bit resolution when sampling an ECG signal.
An approach to implement single-ended power-efficient static class-AB Miller op-amps with symmetrical and significantly enhanced slew-rate and accurately controlled output quiescent current is introduced. The proposed op-amp can drive a wide range of resistive and capacitive loads. The output positive and negative currents can be much higher than the total op-amp quiescent current. The enhanced performance is achieved by utilizing a simple low-power auxiliary amplifier with resistive local common-mode feedback that increases the quiescent power dissipation by less than 10%. The proposed class AB op-amp is characterized by significantly enhanced large-signal dynamic, static current efficiency, and small-signal figures of merits. The dynamic current efficiency is 15.6 higher, the static current efficiency is 10.6 times higher, and the small-signal figure of merit is 2.3 times higher than the conventional class-A op-amp. A global figure of merit that determines an op-amp’s ultimate speed is 6.33 times higher than the conventional class A op-amp.
19 January 2023 in IEEE Transactions on Circuits and Systems II: Express Briefs
This paper presents a dynamic predictive sampling (DPS) based analog-to-digital converter (ADC) that provides a non-uniform sampling of input analog continuous-time signals. The processing unit generates a dynamic prediction of the input signal using two prior-quantized samplings to compute digital values of an upper threshold and a lower threshold. The digital threshold values are converted to analog thresholds to form a tracking window. A dynamic comparator compares the input analog signal with the tracking window to determine if the prediction is successful. A counter records timestamps between the unsuccessful predictions, which are the selected sampling points for quantization. No quantization is performed for successfully predicted sampling points so that the data throughput and power can be saved. The proposed circuits were designed as a 10-bit ADC using 0.18 micro CMOS process sampling at 1 kHz. The results show that the proposed system can achieve a data compression factor of 6.17 and a power saving factor of 31% compared to a Nyquist rate SAR ADC for ECG monitoring.
12 May 2025 in IEEE Transactions on Circuits and Systems II: Express Briefs
Privacy is a huge concern for our modern cyberspace, with the fast development of Internet of Things (IoT) technologies. To preserve data privacy, differential privacy (DP) has been widely applied as the gold standard to offer both utility to applications and rigorous privacy guarantees. However, traditional software-based DP implementation schemes require significant computation and memory resources, which cannot be supported by typical resource-limited IoT edge devices. This brief presents a new failure-tunable memory design to achieve a local DP mechanism. Specifically, a custom 4T SRAM with multiple supply voltages is designed to inject controlled DP noise while data is stored in the memory. The post-simulation results based on a 130CMOS technology show that, compared to state-of the art, our proposed design can achieve a 38% power savings and 61.92% silicon area reduction. In addition, the proposed design demonstrates enhanced controllability on the privacy deployment as compared to traditional 6T-based design, enabling fine-grained control of privacy levels. Accordingly, the proposed memory-based hardware scheme realizes DP with low cost and low power consumption, which makes DP applicable for IoT devices.