Marta Arias Guillén

Dr. Marta Arias Guillén

Hospital Clinic, Barcelona, Catalonia, Spain
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2019 in Blood Purification
Verified
Journal Article
Closed access
PDF file
Francisco MaduellFrancisco Maduell
Francisco Maduell
LRLida Rodas
Lida Rodas
JBJose Jesus Broseta
Jose Jesus Broseta
MGMiquel Gomez
Miquel Gomez
MXMarc Xipell
Marc Xipell
NRNaira Rico
Naira Rico
Background: A novel class of membranes, medium cut-off (MCO) membranes, has recently been designed to achieve interesting removal capacities for middle and large middle molecules in hemodialysis (HD) treatments. The few studies published to date have reported contradictory results regarding middle-sized molecules when comparing MCO dialyzers versus dialyzers used in online hemodiafiltration (OL-HDF). Methods: A prospective, single-center study was carried out in 22 patients. Each patient underwent 9 dialysis sessions with routine dialysis parameters, one with an MCO dialyzer in HD and the other 8 with different dialyzers in OL-HDF. The removal ratio (RR) of urea, creatinine, β2-microglobulin, myoglobin, prolactin, α1-microglobulin, α1-acid glycoprotein, and albumin was intraindividually compared. Albumin loss in dialysate was measured. We propose a global removal score ([ureaRR + β2-microglobulinRR + myoglobinRR + prolactinRR + α1-microglobulinRR + α1-acid glycoproteinRR]/6 – albuminRR) as a new tool for measuring dialyzer effectiveness. Results: No significant differences in the RRs of small and middle molecular range molecules were observed between the MCO vs. OL-HDF dialyzers (range 60–80%). Lower RRs were found for α1-microglobulin and α1-acid glycoprotein without significant differences. The albumin RR was < 11% and dialysate albumin loss was < 3.5 g in all situations without significant differences. The global removal score was 54.9 ± 4.8% with the MCO dialyzer without significant differences. Conclusions: Removal of a wide range of molecular weights, calculated with the proposed global removal score, was almost equal with the MCO dialyzer in HD treatment compared with 8 high-flux dialyzers in high-volume OL-HDF without relevant changes in albumin loss. The global removal score could be a new tool to evaluate the effectiveness of dialyzers and/or different treatment modalities.

30 April 2019 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
Francisco MaduellFrancisco Maduell
Francisco Maduell
LRLida Rodas
Lida Rodas
JBJose Jesus Broseta
Jose Jesus Broseta
MGMiguel Gómez
Miguel Gómez
MXMarc Xipell
Marc Xipell
NRNayra Rico
Nayra Rico

3 October 2019 in Therapeutic Apheresis and Dialysis
Verified
Journal Article
Closed access
PDF file
Francisco MaduellFrancisco Maduell
Francisco Maduell
JBJose Jesus Broseta
Jose Jesus Broseta
LRLida Rodas
Lida Rodas
EMEnrique Montagud‐Marrahi
Enrique Montagud‐Marrahi
DRDiana Rodríguez-Espinosa
Diana Rodríguez-Espinosa
NRNayra Rico
Nayra Rico

17 August 2022 in Nutrients
Verified
Journal Article
Open access
PDF file
MGMarta Arias Guillén
Marta Arias Guillén
SCSilvia Collado
Silvia Collado
ECElisabet Coll
Elisabet Coll
JCJordi Carreras
Jordi Carreras
LCLoreley Betancourt Castellanos
Loreley Betancourt Castellanos
JCJordi Calabia
Jordi Calabia
This cross-sectional study aims to explore the prevalence of protein-energy wasting (PEW) in dialysis patients in Catalonia, Spain, using a new and practical online tool which enables rapid calculation and comparison with other nutritional scores. Methods: A web tool (Nutrendial) was created to introduce different variables and automatically calculate PEW, Malnutrition inflammation Score (MIS) and Subjective Global Assessment (SGA) in 1389 patients (88% in haemodialysis (HD)), 12% in peritoneal dialysis (PD) from different regions of Catalonia. Results: A prevalence of 23.3% (26% HD, 10.2% PD) of PEW was found, with a mean MIS score of 6 and SGA score of C in 7% of the patients. ROC analysis showed MIS as the best nutritional score to diagnose PEW (AUC 0.85). Albumin delivered lower diagnostic precision (AUC 0.77) and sensitivity (66%). A cut off point of 7 (86% sensitivity and 75% specificity) for MIS and 3.7 mg/dL for albumin were found to predict the appearance of PEW in this population. SGA B or C showed an 87% sensitivity and 55% specificity to diagnose PEW. Very low nutritional intervention (14%) was recorded with this tool in patients with PEW. Conclusions: This new online tool facilitated the calculation of PEW, enabling different professionals—including nephrologists, dieticians and nurses—to efficiently obtain insights into the nutritional status of the Catalonian dialysis population and implement the required nutritional interventions. MIS is the score with more sensitivity to diagnose PEW.


12 April 2020 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
Francisco MaduellFrancisco Maduell
Francisco Maduell
JBJose Jesus Broseta
Jose Jesus Broseta
MGMiguel Gómez
Miguel Gómez
PRPablo Racionero
Pablo Racionero
EMEnrique Montagud‐Marrahi
Enrique Montagud‐Marrahi
NRNayra Rico
Nayra Rico