Fawas Omogbolahan Matanmi

Mr. Fawas Omogbolahan Matanmi

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2025 in Engineering Structures
Verified
Journal Article
Closed access
Fawas Omogbolahan MatanmiFawas Omogbolahan Matanmi
Fawas Omogbolahan Matanmi
QSQingtian Su
Qingtian Su
MGMinjie Gu
Minjie Gu
SXShuzhuang Xu
Shuzhuang Xu
FLFengyao Liu
Fengyao Liu
Zhanchong ShiZhanchong Shi
Zhanchong Shi

5 March 2025 in Materials
Verified
Journal Article
Open access
PDF file
WXWei Xie
Wei Xie
BZBinju Zhang
Binju Zhang
LYLitao Yu
Litao Yu
QSQingtian Su
Qingtian Su
Fawas Omogbolahan MatanmiFawas Omogbolahan Matanmi
Fawas Omogbolahan Matanmi
To reduce the maintenance requirements during the service life of highway bridges and enhance the cracking resistance of concrete slabs in the hogging moment zone of continuous composite girders, this paper proposes an innovative girder-to-pier joint for composite bridges with integral piers. Compared to the existing ones, this new joint has structural differences. The middle part of the embedded web is hollowed out to facilitate the construction, and the upper and bottom flanges of the steel girder within this joint are widened. Moreover, cast-in-place ultra-high-performance concrete (UHPC) is applied instead of normal concrete (NC) only on the top surface of the pier. A full-scale test was carried out for this new joint to evaluate the load–displacement relationship, load–strain relationship, crack initiation, and crack propagation. Compared with the numerical simulation results of the reference engineering, the test results demonstrated that the proposed joint exhibited excellent flexural performance and cracking resistance. This paper also proposes a calculation method for the elastic flexural capacity of the girder-to-pier joint incorporating the tensile strength of UHPC, and the calculated result was in good agreement with the experimental result.

13 March 2025 in Materials
Verified
Journal Article
Open access
PDF file
BSBing Shangguan
Bing Shangguan
FWFeng Wang
Feng Wang
QSQingtian Su
Qingtian Su
Fawas Omogbolahan MatanmiFawas Omogbolahan Matanmi
Fawas Omogbolahan Matanmi
JXJun Xu
Jun Xu
Hybrid girder bridges achieve significant improvements in spanning capacity by utilizing lightweight and high-strength materials in the midspan beam segments. To quantitatively describe the enhancement in spanning capacity, this study introduces a simplified analytical model for hybrid girder components, avoiding complex factors, such as span ratio and boundary conditions, typically encountered in previous system-level analyses. The Leq method is proposed based on this new model, utilizing classical beam theory model to calculate and compare hybrid girder components with both uniform and variable cross-sections. The equivalent span increase coefficient, κ, is introduced for the first time, and a simplified formula for its calculation is derived. The calculation errors are kept within 8%, which meets the requirements for preliminary design. Validated through engineering practice, the formula is concise and reveals that κ is solely related to the hybrid ratio, μ, and the linear load ratio, γ. This method provides valuable guidance for the conceptual design and ultimate span prediction of hybrid girder bridges.

26 September 2025 in Buildings
Verified
Journal Article
Open access
PDF file
CSChong Shen
Chong Shen
QSQingtian Su
Qingtian Su
Sizhe WangSizhe Wang
Sizhe Wang
Fawas Omogbolahan MatanmiFawas Omogbolahan Matanmi
Fawas Omogbolahan Matanmi
To reduce the weight of prefabricated cap beams, a new type of hybrid pier with a steel cap beam and single concrete column with an innovative flange–rebar–ultra-high-performance concrete (UHPC) connection structure is proposed in this paper. Focusing on the static performance of hybrid piers, a specimen with a geometric similarity ratio of 1:4 was fabricated for testing. The results showed that the ultimate load-bearing capacity reached 960 kN, and the failure mode was characterized by an obvious overall vertical displacement of 70.2 mm at the cantilever end, accompanied by local buckling in the webs between transversal diaphragms and ribs. Due to the varying-thickness design, longitudinal strains were comparable between the middle section (thin plates) and the root section (thick plates) of the cantilever beam, showing a trend of an initial increase followed by a decrease from the end of the cantilever beam to the road centerline. Meanwhile, the cross-sections of the connection joint and concrete column transformed from overall compression to eccentric compression during the test. At the ultimate state, their steel structures remained elastic, with no obvious damage in the concrete or UHPC, verifying good load-bearing capacity. Furthermore, the finite element analysis showed the new connection joint and construction method of hinged-to-rigid could reduce the column top concrete compressive stress by 18–54%, tensile stress by 11–68%, and steel cap beam Mises stress by 10%. Finally, based on the experimental and numerical studies, the safety reserve coefficient of the new hybrid pier was over 2.7.

14 September 2026 in Engineering Structures
Verified
Journal Article
Closed access
Fawas Omogbolahan MatanmiFawas Omogbolahan Matanmi
Fawas Omogbolahan Matanmi
QSQingtian Su
Qingtian Su
YLYangqing Liu
Yangqing Liu
LHLefei Huang
Lefei Huang
RXRunchuan Xu
Runchuan Xu
RZRui Zhao
Rui Zhao

19 May 2026 in Infrastructures
Verified
Journal Article
Open access
PDF file
LYLi-Tao Yu
Li-Tao Yu
CYChunbin Yu
Chunbin Yu
Fawas Omogbolahan MatanmiFawas Omogbolahan Matanmi
Fawas Omogbolahan Matanmi
ZLZhiping Lin
Zhiping Lin
The application of ultra-high performance concrete (UHPC) in the hogging moment region significantly enhances the crack resistance of concrete slabs of composite girders with integrated piers, while also providing economic benefits. To investigate the crack resistance performance and develop a calculation method for crack width in hogging moment region of steel–UHPC–normal concrete (NC) composite girders, a full-scale bending test was conducted. Based on the test results, the post-cracking residual tensile strength of UHPC was determined according to the energy equivalence principle. A calculation method for reinforcement stress incorporating the tensile contribution of UHPC at a cracked section was proposed and then the applicability for current design codes for crack width calculation was evaluated. For the UHPC–NC interface, a corresponding crack width calculation method was developed. The results indicate that cracks initiated on the surface of the NC layer beneath the UHPC overlay at the cantilever root. Then cracks developed in sequence at the top surface of the UHPC layer cantilever root, the UHPC–NC interface, and the mid-plane of the girder-to-pier joint. Ultimately, UHPC cracks exhibited a “numerous and closely spaced” distribution, whereas NC cracks were “few and widely spaced.” When the residual tensile strength of UHPC at cracked section was considered, the mean value and average coefficient of variation in the ratios of calculated to measured reinforcement stresses for different sections were 1.07 and 0.10, respectively, which can be further used for crack width calculation. The mean ratios of code-predicted to measured UHPC crack widths for different sections using the Chinese code, French code, and European code were 1.10, 0.98, and 1.13, respectively, with corresponding average coefficients of variation of 0.25, 0.33, and 0.28; the Chinese code is recommended for UHPC crack width prediction. For the UHPC–NC interface, an expression for crack width calculation was derived using the comprehensive theory, and the mean ratio of calculated to measured values and the coefficient of variation were 1.08 and 0.18, respectively, demonstrating good predictive accuracy.