The application of prestress is a very effective way to prevent the cracking of the concrete slab in the negative-moment region of continuous composite girders, and using a prefabricated prestressed-concrete slab in this region is an easier option than posttensioning. To elucidate the structural response of a continuous composite box girder with a prefabricated prestressed-concrete slab, two large, 18-m-long specimens were fabricated and tested under short-term loading, and the results are reported in this paper. One, a control specimen, was a conventional composite girder with its concrete slab cast in situ, whereas the other was a composite box girder with a prefabricated prestressed-concrete slab in the negative-moment region. The relative slip between the steel girder and the concrete slab; the load-deflection response; the distribution of strain in the steel girder, reinforcement, and concrete slab; as well as the crack widths in the concrete slab were measured during the tests. The paper shows that, although the ultimate strengths of the two specimens are almost the same, the initial cracking load and serviceability limit state load of the specimen with a prefabricated prestressed-concrete slab are 3.16 and 2.61 times, respectively, those of the specimen with a conventional concrete slab. It is also shown that simple linear-elastic analysis leads to a close prediction of the load for initial cracking. By comparison, a continuous composite bridge beam with a prefabricated prestressed slab over its internal support is stiffer and less likely to experience the ingress of corrosive materials than one with a conventional RC slab is.
The orthotropic steel–concrete composite deck, which consists of a concrete slab, an orthotropic steel plate, and shear connectors, has been applied for ameliorating the vehicle-induced fatigue damage on steel bridge decks. However, its static performance, especially its negative bending performance, has rarely been considered, despite its critical role in bridge durability and safety. Accordingly, negative bending tests on four full-scale composite deck specimens were carried out, in which the effects of steel-fiber-reinforced concrete (SFRC), the reinforcement ratio, and the shear connector type were investigated. The full-scale orthotropic steel plates of the test specimens were stiffened by large U-ribs, which were designed for construction convenience and cost reduction in applied engineering practice. The test results show that the bending stiffness of the composite deck was influenced by the reinforcement ratio and the shear connector type, and the load-carrying capacity was sensitive to the reinforcement ratio. The ultimate status was found to be dominated by buckling of the steel ribs. The use of SFRC had an obvious restraining effect on the crack-width development. Finally, the applicability of the current codes for the composite girder to the composite deck was verified by comparing the corresponding evaluations of reinforcement stress, bending stiffness, and crack feature with the test results.
7 May 2018 in International Journal of Steel Structures
Prestressed steel-concrete composite girders constructed by postconnection have gained increasing attention in bridge engineering in recent years. By prestressing the concrete slabs before connecting them with the steel girders in the hogging regions subject to negative moments, this new construction method for steel-concrete composite girders is capable of mitigating the risk of concrete cracking in continuous girders to improve the safety and serviceability of bridges. To study the complex stress and strain distributions in the prestressed composite section as well as their nonlinear evolution with time, a three-dimensional (3D) viscoelastoplastic damage constitutive model is presented in this investigation. In this model, the instantaneous responses of concrete are described by an elastoplastic damage model, and the time-dependent concrete creep and shrinkage are approximated based on an improved rate-type formulation. Compared with the one-dimensional (1D) elastic analysis widely used in current practice, the proposed model provides detailed and realistic information of the stress and strain distributions within the entire composite section during construction and in service. In a case study of a real continuous girder, the coupled effects of concrete shrinkage, creep, and cracking on the long-term behavior of the composite section are estimated based on the proposed model. Furthermore, a parametric study on the curing duration shows that this new construction method can be further improved by controlling the concrete shrinkage.
30 September 2017 in International Journal of Steel Structures
A hybrid girder bridge adopts a steel segment at the mid-span of the main span of a continuous concrete girder bridge. The critical point of the hybrid solution is the transition zone, connecting the steel and concrete segments of the beam. Although many girder tests revealing the structural behavior of hybrid girders have been conducted by previous studies, few specimens took the full section of a steel–concrete joint due to the large size of prototype hybrid bridges. In this study, a static load test on a composite segment to bridge the joint between the concrete and steel parts of a hybrid bridge with full section was conducted. A finite element model replicating the tested specimen results was established through Abaqus, while parametric studies were also conducted. The test and numerical results revealed that the concrete filling in the composite solution prevented the steel flange from extensive buckling, which significantly improved the load-carrying capacity of the steel–concrete joint. Meanwhile, strengthening the interaction between the steel and concrete helps to prevent the interlayer slip and simultaneously contributes to a higher flexural stiffness. These results are an important basis for establishing a rational design scheme for the steel–concrete joint of hybrid girder bridges.