Purpose: To critically appraise and summarize the potential of linear and/or volumetric dimensions of the maxillary sinuses obtained with cone-beam and multi-slice computed tomography. Methods: A bibliographic search was conducted in seven databases in August, 2023. Cross-sectional retrospective studies using linear and volumetric measurements of the maxillary sinuses obtained with cone-beam and multi-slice computed tomography for sex estimation and presenting numerical estimation data were included. Narrative or systematic reviews, letters to the editor, case reports, laboratory studies in animals, and experimental studies were excluded. The critical appraisal and certainty of evidence were assessed using the guidelines described by Fowkes and Fulton and GRADE, respectively. Results: A total of 656 studies were found, 32 of which were included. A total of 3631 individuals were analyzed and the overall sex estimation rate ranged from 54.9% to 95%. When compared with isolated measurements, combined linear measurements of the right and left maxillary sinuses, such as width, length, and height, provided a higher rate of sex estimation (54.9-95%). In most of the studies (62.5%), all measurements were higher in men than in women. Multiple methodological problems were found in the studies, especially distorting influences in 84.4% of the answers. The certainty of evidence varied from very low to low. Conclusions: The combination of height, width, and length measurements of the right and left maxillary sinuses from cone-beam and multi-slice computed tomography can be useful in the estimation of sex of humans. Further primary studies are needed to increase the certainty of evidence. PROSPERO register: CRD42020161922
The aim of this study is to quantitatively evaluate the influence of the duration of ambient light exposure on the image quality of digital radiographs obtained with contemporary phosphor plate (PSP)-based systems. Radiographs of an aluminum step-wedge were obtained using VistaScan and Express systems at five X-ray exposure times: 0.10, 0.20, 0.32, 0.40, and 0.50 s; the resulting dose-area products were, respectively, 21.93, 43.87, 70.19, 87.75, and 109.6 mGycm2. Before PSP read-out, half of the sensitive surface of the PSP plates was exposed to ambient light for 5, 10, 30, 60, and 90 s. The effect of light exposure on brightness, contrast, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and image saturation was compared using ANOVA with the Tukey test (α = 0.05). Ambient light exposure increased brightness and contrast and reduced CNR and SNR in PSP-based radiographs of contemporary digital systems. At the longest X-ray exposure times, ambient light exposure reduced the dark saturation (mean gray values ≤ 1) observed in Express. In conclusion, the negative effects of ambient light observed on the image quality of PSP-based radiographs are directly proportional to the duration of exposure. Clinicians should be aware of such harmful effects when handling and scanning PSP plates in bright environments.
Accurate estimation of age and sex is crucial in forensic and clinical contexts, however conventional methods are subjective and time-consuming. Panoramic radiographs offer valuable data for automated analysis. Therefore, the aim of this study was to present and evaluate a multi-task deep learning framework based on ForensicNet for simultaneous estimation of chronological age and classification of sex using panoramic radiographs of the Brazilian young population aged 5-15 years. A total of 2200 high-resolution panoramic radiographs were retrospectively collected, balanced by age and sex. After applying strict inclusion/exclusion criteria, the images were randomly split into training (1320), validation (440), and test (440) sets. A multi-task DL model based on EfficientNet-B3 was implemented with task-specific branches incorporating Convolutional Block Attention Modules (CBAM) to predict age and sex. The model was trained end-to-end using a weighted multi-task loss (α = 0.3 for age, β = 0.7 for sex) and evaluated against five benchmark architectures. Grad-CAM was used for model interpretability. The proposed ForensicNet outperformed all baseline models, achieving the lowest mean absolute error and highest coefficient of determination in age prediction, and highest accuracy and area under the curve in sex classification. Grad-CAM visualisations confirmed the model's focus on anatomically relevant areas. Ablation studies showed that removing CBAM or altering task weights reduced performance. The proposed ForensicNet-based multi-task deep learning model demonstrated robust performance in both chronological age estimation and sex classification using panoramic radiographs from young Brazilian individuals, supporting its potential forensic and clinical applicability. This framework may assist forensic experts and clinicians by providing fast, objective and reproducible estimations of age and sex from routinely acquired panoramic radiographs, potentially improving identification processes in forensic and pediatric contexts.
O carcinoma espinocelular é a neoplasia mais frequente na cavidade oral. O tratamento com quimioterapia e radioterapia pode resultar em xerostomia e hipossalivação, sintomas que podem ser tratados com laserterapia de baixa intensidade. Este trabalho tem como objetivo relatar um caso de melhoria da xerostomia e da hipossalivação num paciente irradiado na região da cabeça e do pescoço tratado com laserterapia de baixa intensidade. Paciente do sexo masculino, 48 anos, queixou-se de boca seca. Tinha sido submetido a tratamento cirúrgico, quimioterapia e radioterapia devido a um carcinoma espinocelular da base da língua. Foi feito o planeamento de 10 sessões de laserterapia de baixa intensidade no modo infravermelho com aplicação de 1 J em pontos extra e intraorais e prescrição de saliva artificial. Foi observada melhoria no quadro por meio de escala visual analógica. São necessários novos estudos para avaliação do tratamento com laserterapia de baixa intensidade para esses sintomas, com o intuito de melhorar a qualidade de vida desses indivíduos.
20 December 2024 in Clinical Oral Implants Research
Objectives: To evaluate the influence of different dental implant materials within the exomass on the image quality in cone‐beam computed tomography (CBCT).Material and Methods: Five pig jaws were scanned using four CBCT devices, first without any dental implants, followed by scans with three dental implants of the same material—pure titanium, titanium‐zirconium alloy, and zirconium dioxide. Two fields of view (FOVs) were used for each device to position the implants in the exomass of a small FOV and within a large FOV. Voxel values were obtained from tubes containing a radiopaque solution to calculate mean voxel value (MVV), voxel value inhomogeneity (VVI), and image noise (IN), which were compared across implant materials and FOVs using repeated measures analysis of variance (α = 0.05). Three observers independently scored image quality using a 5‐point scale.Results: In general, MVV remained unaffected, except for a significant increase in the X800 device when titanium or titanium‐zirconium alloy implants were in the exomass of a small FOV (p ≤ 0.05). A trend of increased VVI was observed when implants were in the exomass of a small FOV, with a greater effect for zirconium dioxide, followed by titanium‐zirconium alloy and titanium. IN was higher when implants were in the exomass, especially for zirconium dioxide implants (p ≤ 0.05). Image quality perception was consistent overall, though zirconium dioxide implants in both FOVs resulted in diminished quality.Conclusions: The presence of implants in the exomass can negatively affect CBCT image quality, with zirconium dioxide having the greatest impact.