This study investigates the influence of various printing parameters on the tensile, compressive, and bending stiffness of fused deposition modeling (FDM)-printed polylactic acid (PLA) parts through a comprehensive full factorial design of experiment. Key factors, including infill percentage, infill pattern, number of outer shells, and part orientation, were systematically varied to quantify their impact on mechanical performance. A total of 36 parameter combinations, selected based on a literature review and experimental feasibility, were tested using standardized specimens: beams for bending, cylinders for compression, and dogbones for tensile testing. Mechanical tests were performed according to ISO 5893:2019, employing a 1 kN load cell to determine stiffness and elastic modulus. The results indicate that the number of outer shells and infill density are the most influential parameters, whereas infill pattern and part orientation have a minor effect, depending on the loading condition. This study provides a novel and robust evaluation of the interactions between key printing parameters, offering new insights into optimizing the mechanical properties of FDM-printed parts. These findings establish a foundation for further optimization and material selection in future additive manufacturing research.
Purpose: This finite element study aims to compare the biomechanical performance of three total knee arthroplasty (TKA) alignment strategies—mechanical alignment, kinematic alignment and inverse kinematic alignment—in knees with different degrees of varus deformity. We hypothesise that alignment choice has limited impact in rather neutral alignment but significant biomechanical effects in mild deformity. Methods: Two osteoarthritic patients scheduled for TKA, one with almost neutral alignment (1.5°) and one with mild (10.4°) varus deformity, were selected. For each patient, mechanical alignment, kinematic alignment and inverse kinematic alignment strategies were virtually applied using a posterior‐stabilised fixed‐bearing implant. Patient‐specific knee joint geometries, including bones and ligaments, were modelled from CT scans. Gait simulations were conducted following ISO standard. Outputs analysed and compared among alignments included contact areas and contact forces, von Mises stress on the tibial insert, tibial anterior‐posterior translation and tibial internal‐external rotation. Results: In the almost neutral knee, all three alignments showed comparable kinematics and kinetics. However, in the mildly deformed case, notable differences emerged. Kinematic alignment achieved more balanced medial‐lateral contact areas and forces, while inverse kinematic alignment displayed increased internal‐external rotation, indicating potential instability from suboptimal ligament balance. Mechanical alignment resulted in higher medial stress, while kinematic alignment redistributed stress more evenly. Inverse kinematic alignment exhibited intermediate behaviour, resembling mechanical alignment in force distribution under mild deformity. Conclusion: Alignment strategy plays a critical role in TKA biomechanics, especially in case of patients with mild varus deformity. While similar outcomes are achievable with almost no deformities, patient‐specific morphology heavily influences performance under more complex geometries. These findings support the adoption of a personalised alignment approach tailored to individual anatomical characteristics rather than rigid adherence to a single alignment philosophy. Level of Evidence: N/A.
13 July 2025 in Journal of Experimental Orthopaedics
Purpose: Augmented reality (AR) technology is emerging as a viable alternative for improving surgical precision in total knee arthroplasty (TKA). While previous studies have assessed AR accuracy, limited research has explored its learning curve and long‐term performance. This study evaluates the accuracy of an AR‐assisted system in achieving pre‐planned osteotomies and investigates potential improvements over time with increased surgical experience. Methods: A total of 157 patients underwent TKA using an AR‐based guidance system, with preoperative planning defining varus/valgus and posterior slope angles. The achieved angles were compared to planned values using two error assessment metrics. Additionally, the data from the first 76 procedures were compared to the last 81 to assess a learning curve effect. Surgical time and blood loss were also evaluated. Results: The AR system maintained high accuracy, with mean deviations of 0.47 ± 0.54° for varus/valgus and 0.76 ± 0.74° for posterior slope. Errors remained below 1° in the majority of cases (98.1% for varus/valgus and 86.0% for posterior slope). Over time, a learning effect was observed, with mean errors decreasing by up to 44.6% for varus/valgus and 8.6% for posterior slope. No significant differences were found in surgery duration or blood loss between the AR and control groups. Conclusions: This study confirms the reliability of AR‐based guidance in TKA, demonstrating its ability to achieve precise osteotomies with minimal intraoperative variability. Additionally, the results suggest a learning curve effect, with improved accuracy over time. These findings support AR as a promising, cost‐effective alternative to robotic navigation in knee surgery. Level of Evidence: Level II.
1 April 2026 in Journal of Experimental Orthopaedics
Purpose: The analysis of knee joint biomechanics under intraoperative‐like conditions is fundamental to support surgical decisions and improve clinical outcomes. Many experimental systems developed in recent years are characterized by high complexity and limited portability, which may restrict the reproduction of surgical intraoperative workflows. Therefore, this study describes the design and experimentally validates a compact and portable testing platform capable of accurately analysing knee tibio‐femoral and patello‐femoral kinematics and laxity under intraoperative‐like conditions. Methods: The system integrates motion capture, mechanical fixation, motor‐driven actuation, force measurement and dedicated software into a unique platform. It enables passive and active open‐chain knee motions, as well as standardized ligament laxity testing. Tibio‐femoral and patello‐femoral kinematics are simultaneously recorded while quadriceps and external forces are measured respectively through mono‐axial and tri‐axial load cells. System accuracy and repeatability were assessed through load cell calibration and dynamic testing on a synthetic knee model. Transportability, setup time and overall performance were evaluated under realistic ex vivo experimental conditions. Results: Validation demonstrated close agreement between set and measured loads, with measurement accuracies of approximately 1% for quadriceps forces and 0.75% for externally applied knee forces. Motor‐driven motion showed high repeatability, with mean standard deviations of 0.51° for flexion–extension cycles and 1.62° for multiple dynamic flexion tests. Motion capture calibration achieved a pointer tip positional error of approximately 0.20 mm. Ex vivo testing confirmed reliable reproduction of knee motion and highly reproducible measurement, with rapid set‐up and workflow smoothness. Conclusion: The system represents a portable, accurate, repeatable and validated experimental platform for biomechanical assessment of knee joint kinematics and laxity under intraoperative‐like conditions. Its modular design, rapid setup and capability to combine kinematic and kinetic measurements make it a valuable tool for investigating the biomechanical impact of surgical techniques or implants, and patient‐specific joint behaviour in ex vivo settings. Level of Evidence: N/A.
While total knee arthroplasty (TKA) is highly successful, wear, primary fixation stability and structural failure remain significant challenges, particularly in patients with diverse kinetic profiles and compromised bone. This study evaluates a fixed-bearing cruciate-retaining TKA prosthesis under extreme load variability in healthy and osteoporotic bone. Finite element simulations utilized ISO-standardized baseline gait cycle, scaling independently axial forces, antero-posterior forces, and rotational torque to 50% and 200%. Polyethylene insert stress, tibial stress, and bone–implant micromotion were evaluated to assess structural safety, load transfer, and primary stability. Kinetic variability directly influenced the stress magnitude and load transfer. Insert load distribution revealed a compartmental split (medial side bearing 47.6% to 60.9%) sensitive to force orientation and translational load magnitudes (axial and shear), but totally independent of rotational torque magnitude. While reduced bone quality did not significantly affect overall polyethylene stresses, it directly impacted primary stability. Osteoporotic conditions nearly doubled the total baseline interface micromotion (from 19 µm to 37 µm) and exhibited an absolute maximum of 63 µm under 200% axial load scaling. These findings highlight the necessity of definition of model parameters for careful preclinical planning for patients with compromised bone quality regarding prosthesis selection, fixation method and alignment.