Mihai Burlibasa

Prof. Mihai Burlibasa

Dental Technology, Carol Davila University of Medicine and Pharmacy, Bucharest, Bucureşti, Romania

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Corina Marilena CristacheCorina Marilena Cristache
Corina Marilena Cristache
Ioana TudorIoana Tudor
Ioana Tudor
LMLiliana Moraru
Liliana Moraru
GCGheorghe Cristache
Gheorghe Cristache
LANZA ALESSANDROLANZA ALESSANDRO
LANZA ALESSANDRO
MBMihai Burlibasa
Mihai Burlibasa
Background: A maxillofacial prosthesis, an alternative to surgery for the rehabilitation of patients with facial disabilities (congenital or acquired due to malignant disease or trauma), are meant to replace parts of the face or missing areas of bone and soft tissue and restore oral functions such as swallowing, speech and chewing, with the main goal being to improve the quality of life of the patients. The conventional procedures for maxillofacial prosthesis manufacturing involve several complex steps, are very traumatic for the patient and rely on the skills of the maxillofacial team. Computer-aided design and computer-aided manufacturing have opened a new approach to the fabrication of maxillofacial prostheses. Our review aimed to perform an update on the digital design of a maxillofacial prosthesis, emphasizing the available methods of data acquisition for the extraoral, intraoral and complex defects in the maxillofacial region and assessing the software used for data processing and part design. Methods: A search in the PubMed and Scopus databases was done using the predefined MeSH terms. Results: Partially and complete digital workflows were successfully applied for extraoral and intraoral prosthesis manufacturing. Conclusions: To date, the software and interface used to process and design maxillofacial prostheses are expensive, not typical for this purpose and accessible only to very skilled dental professionals or to computer-aided design (CAD) engineers. As the demand for a digital approach to maxillofacial rehabilitation increases, more support from the software designer or manufacturer will be necessary to create user-friendly and accessible modules similar to those used in dental laboratories.

Verified
Journal Article
Open access
PDF file
Corina Marilena CristacheCorina Marilena Cristache
Corina Marilena Cristache
MBMihai Burlibasa
Mihai Burlibasa
Ioana TudorIoana Tudor
Ioana Tudor
Eugenia Eftimie TotuEugenia Eftimie Totu
Eugenia Eftimie Totu
FFFabrizio Di Francesco
Fabrizio Di Francesco
LMLiliana Moraru
Liliana Moraru
(1) Background: Prosthetically-driven implant positioning is a prerequisite for long-term successful treatment. Transferring the planned implant position information to the clinical setting could be done using either static or dynamic guided techniques. The 3D model of the bone and surrounding structures is obtained via cone beam computed tomography (CBCT) and the patient’s oral condition can be acquired conventionally and then digitalized using a desktop scanner, partially digital workflow (PDW) or digitally with the aid of an intraoral scanner (FDW). The aim of the present randomized clinical trial (RCT) was to compare the accuracy of flapless dental implants insertion in partially edentulous patients with a static surgical template obtained through PDW and FDW. Patient outcome and time spent from data collection to template manufacturing were also compared. (2) Methods: 66 partially edentulous sites (at 49 patients) were randomly assigned to a PDW or FDW for guided implant insertion. Planned and placed implants position were compared by assessing four deviation parameters: 3D error at the entry point, 3D error at the apex, angular deviation, and vertical deviation at entry point. (3) Results: A total of 111 implants were inserted. No implant loss during osseointegration or mechanical and technical complications occurred during the first-year post-implants loading. The mean error at the entry point was 0.44 mm (FDW) and 0.85 (PDW), p ≤ 0.00; at implant apex, 1.03 (FDW) and 1.48 (PDW), p ≤ 0.00; the mean angular deviation, 2.12° (FDW) and 2.48° (PDW), p = 0.03 and the mean depth deviation, 0.45 mm (FDW) and 0.68 mm (PDW), p ≤ 0.00; (4) Conclusions: Despite the statistically significant differences between the groups, and in the limits of the present study, full digital workflow as well as partially digital workflow are predictable methods for accurate prosthetically driven guided implants insertion.

4 July 2025 in Prosthesis
Verified
Journal Article
Open access
PDF file
MPMircea Popescu
Mircea Popescu
VPViorel Stefan Perieanu
Viorel Stefan Perieanu
MBMihai Burlibasa
Mihai Burlibasa
AVANDREI VOROVENCI
ANDREI VOROVENCI
MMMădălina Adriana Malița
Mădălina Adriana Malița
Liliana BurlibasaLiliana Burlibasa
Liliana Burlibasa
Objectives: This systematic review aimed to evaluate the cost, production time, clinical performance, and patient satisfaction of 3D printing workflows in prosthodontics compared to conventional and subtractive methods. Methods: Following PRISMA guidelines, a systematic search of electronic databases was performed to identify studies published between 2015 and 2025 that directly compared digital additive workflows with analogue or subtractive workflows. Studies were eligible if they included prosthodontic treatments such as dentures, crowns, or implant-supported prostheses and reported at least one relevant outcome. The primary outcomes were cost, time efficiency, clinical accuracy (e.g., marginal adaptation, fit), and patient satisfaction. Included studies were methodologically evaluated using MINORS scale and the risk of bias was assessed using ROBINS-I and RoB 2 tools. Results: Seven studies met the inclusion criteria. Overall, 3D printing workflows demonstrated reduced production time and cost in comparison to conventional or subtractive methods. Clinical outcomes were generally comparable or superior, particularly regarding adaptation and fit. Patient satisfaction was favourable in most studies, although reporting varied. Long-term follow-up was limited, which constrains the interpretation of sustained clinical performance. Conclusions: These findings suggest that 3D printing can serve as an efficient and cost-effective alternative in prosthodontic fabrication, with clinical results comparable to those already established. Further research is needed to assess long-term clinical performance and cost-effectiveness in various clinical scenarios.

20 November 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SDsergiu drafta
sergiu drafta
Liliana BurlibasaLiliana Burlibasa
Liliana Burlibasa
Corina Marilena CristacheCorina Marilena Cristache
Corina Marilena Cristache
IBIrina Adriana Beuran
Irina Adriana Beuran
MBMihai Burlibasa
Mihai Burlibasa
Liliana BurlibasaLiliana Burlibasa
Liliana Burlibasa
Background: The mechanisms of periimplantitis are mostly based on biofilm-induced inflammatory lesions around dental implants. However, the host reaction, reflected by the intensity of the inflammatory response to bacterial products, is crucial for peri-implant bone destruction. The aim of this pilot study was to measure total antioxidant status (TAS), the amount of IL-6, IL-8 and TNF-α (tumor necrosis factor), salivary lactate dehydrogenase (LDH) levels and the correlation with one-year peri-implant bone loss. Methods: Seven consecutive patients (Group 1), with the presence of at least one prior inserted dental implant, and three healthy individuals, fully dentate (Group 0), were enrolled. IL-6, IL-8, TNF-α, TAS and LDH were determined in saliva of both groups. Peri-implant marginal bone loss (MBL) at one year compared to baseline was evaluated for Group 1. Results: A statistically significant positive correlation was found in Group 1 between MBL and the IL-8 (p = 0.033) and a strong negative correlation between MBL and TAS (p = 0.002), but no statistically significant differences of the assessed parameters were found between the two groups. Conclusions: In the limits of the present preliminary study, salivary TAS and proinflammatory cytokines could be associated with the risk of peri-implant bone loss over time.

7 May 2023 in Healthcare
Verified
Journal Article
Open access
PDF file
ADAndi Ciprian Dragus
Andi Ciprian Dragus
AMAugustin Mihai
Augustin Mihai
GTGabriela Tanase
Gabriela Tanase
MBMihai Burlibasa
Mihai Burlibasa
Corina Marilena CristacheCorina Marilena Cristache
Corina Marilena Cristache
(1) Background: The temporomandibular joint (TMJ) is the most complex and one of the most important joints in the human body due to its essential roles in mastication, swallowing, breathing and speech. Several instruments have been used to track mandibular movements and register the characteristic parameters of the TMJ, among which condylography instruments are validated for the accurate clinical registration of the condylar path. Sagittal condylar inclination (SCI) is one of the most important parameters, together with the Bennett angle and the immediate side shift, used for articular settings in the process of oral rehabilitation. The aim of the present study was to evaluate the differences between the left and right SCI and to assess whether the differences were statistically significant for skeletal class, age, gender, dentate status, TMJ pathology or parafunctional habits. (2) Methods: One hundred and forty consecutive patients, fully dentate or partially edentulous, and with angle class I, II and II, were recruited. Their left and right SCIs were determined with an ultrasonic jaw tracking device. Each subject had to make three protrusive movements and three right and left laterotrusive movements. The software calculated the SCI from the mean of the protrusive movements. (3) Results: The mean values obtained for the right and left SCI were 34.68° (±12.44°) and 34.94° (±13.23°), respectively, with no statistically significant differences between the left and right values for gender, dentate status, TMJ disorders or parafunctional habits. Skeletal class III subjects registered lower SCI means, which were statistically significant for the left SCI. (4) Conclusions: For an optimal functionalization of prosthetic restorations and for an ideal treatment plan, the registration of both the left and right paths of the condyles and the articular disc should be taken into consideration.

28 August 2025 in Oral
Verified
Journal Article
Open access
PDF file
MPMircea Popescu
Mircea Popescu
MMMădălina Adriana Malița
Mădălina Adriana Malița
AVANDREI VOROVENCI
ANDREI VOROVENCI
ASAndreea Angela Stetiu
Andreea Angela Stetiu
VPViorel Stefan Perieanu
Viorel Stefan Perieanu
MBMihai Burlibasa
Mihai Burlibasa
Objective: This systematic review and meta-analysis aimed to evaluate the effects of moisture control strategies (including wet-bonding techniques, universal adhesives, and etching type) on dentin bonding performance in restorative dentistry. Methods: A comprehensive literature search was conducted across PubMed, Scopus, and Google Scholar, following PRISMA guidelines. Only in vitro and ex vivo studies comparing wet- and dry-bonding protocols, using human dentin substrates, and reporting microtensile bond strength (μTBS) were included. The data were synthesized using a random-effects meta-analysis and the methodological quality was assessed using the MINORS tool. Certainty of evidence was evaluated using the GRADE framework. Results: Nine studies met the inclusion criteria, eight of which were included in this meta-analysis. The moisture control strategies significantly influenced the bonding outcomes, with ethanol and acetone wet bonding yielding higher μTBS and enhanced hybrid layer morphology. The universal adhesives performed effectively under both moist and dry conditions, although their performance varied by the adhesive composition and solvent system. The meta-analysis revealed a statistically significant advantage for hydrated dentin (SMD = +1.20; 95% CI: 0.52 to 1.86; p < 0.001), with the moist and ethanol-treated substrates outperforming the dry and over-wet surfaces. The long-term durability was better preserved with ethanol and acetone pretreatments and the adjunctive use of chlorhexidine. Conclusions: Moisture conditions influence dentin bond strength, but modern universal adhesives show consistent bonding performance across different moisture conditions. Solvent-wet-bonding protocols, particularly with ethanol or acetone, enhance the immediate and long-term performance. While the current evidence is limited by the in vitro designs and heterogeneity, the findings demonstrate protocol flexibility and highlight strategies to optimize adhesion in clinical practice. Future clinical trials are necessary to validate these approaches under real-world conditions.