Giam Trinh

Dr. Giam Trinh

Lecturer in Trauma & Orthopaedic of Pham Ngoc Thach Medical University-Viet nam
+2
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 September 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Giam TrinhGiam Trinh
Giam Trinh
HSHao-Chiang Shao
Hao-Chiang Shao
KHKevin Li-Chun Hsieh
Kevin Li-Chun Hsieh
CLChing-Yu Lee
Ching-Yu Lee
HLHsiao-Wei Liu
Hsiao-Wei Liu
THTsung-Jen Huang
Tsung-Jen Huang
Spondylolisthesis refers to the displacement of a vertebral body relative to the vertrabra below it, which can cause radicular symptoms, back pain or leg pain. It usually occurs in the lower lumbar spine, especially in women over the age of 60. The prevalence of spondylolisthesis is expected to rise as the global population ages, requiring prudent action to promptly identify it in clinical settings. The goal of this study was to develop a computer-aided diagnostic (CADx) algorithm, LumbarNet, and to evaluate the efficiency of this model in automatically detecting spondylolisthesis from lumbar X-ray images. Built upon U-Net, feature fusion module (FFM) and collaborating with (i) a P-grade, (ii) a piecewise slope detection (PSD) scheme, and (iii) a dynamic shift (DS), LumbarNet was able to analyze complex structural patterns on lumbar X-ray images, including true lateral, flexion, and extension lateral views. Our results showed that the model achieved a mean intersection over union (mIOU) value of 0.88 in vertebral region segmentation and an accuracy of 88.83% in vertebral slip detection. We conclude that LumbarNet outperformed U-Net, a commonly used method in medical image segmentation, and could serve as a reliable method to identify spondylolisthesis.

14 March 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
ABAnh Tuan Bui
Anh Tuan Bui
Giam TrinhGiam Trinh
Giam Trinh
MWMeng-Huang Wu
Meng-Huang Wu
THTung Thanh Hoang
Tung Thanh Hoang
MHMing-Hsiao Hu
Ming-Hsiao Hu
JPJwo-Luen Pao
Jwo-Luen Pao
Objective: In this systematic review, we summarized the indications for and outcomes of three main unilateral biportal endoscopic (UBE) approaches for the decompression of degenerative lumbar spinal stenosis (DLSS). Methods: A comprehensive search of the literature was performed using Ovid Embase, PubMed, Web of Science, and Ovid’s Cochrane Library. The following information was collected: surgical data; patients’ scores on the Visual Analog Scale (VAS), Oswestry Disability Index (ODI), and Macnab criteria; and surgical complications. Results: In total, 23 articles comprising 7 retrospective comparative studies, 2 prospective comparative studies, 12 retrospectives case series, and 2 randomized controlled trials were selected for quantitative analysis. The interlaminar approach for central and bilateral lateral recess stenoses, contralateral approach for isolated lateral recess stenosis, and paraspinal approach for foraminal stenosis were used in 16, 2, and 4 studies, respectively. In one study, both interlaminar and contralateral approaches were used. L4-5 was the most common level decompressed using the interlaminar and contralateral approaches, whereas L5-S1 was the most common level decompressed using the paraspinal approach. All three approaches provided favorable clinical outcomes at the final follow-up, with considerable improvements in patients’ VAS scores for leg pain (63.6–73.5%) and ODI scores (67.2–71%). The overall complication rate was <6%. Conclusions: The three approaches of UBE surgery are effective and safe for the decompression of various types of DLSS. In the future, long-term prospective studies and randomized control trials are warranted to explore this new technique further and to compare it with conventional surgical techniques.

Verified
Journal Article
Open access
PDF file
TLTU NGOC LAM
TU NGOC LAM
Giam TrinhGiam Trinh
Giam Trinh
CHChih Chieh Huang
Chih Chieh Huang
PKPei-Ching Kung
Pei-Ching Kung
WHWei-Chin Huang
Wei-Chin Huang
E-Wen HuangE-Wen Huang
E-Wen Huang
In this study, we optimized the geometry and composition of additive-manufactured pedicle screws. Metal powders of titanium-aluminum-vanadium (Ti-6Al-4V) were mixed with reactive glass-ceramic biomaterials of bioactive glass (BG) powders. To optimize the geometry of pedicle screws, we applied a novel numerical approach to proposing the optimal shape of the healing chamber to promote biological healing. We examined the geometry and composition effects of pedicle screw implants on the interfacial autologous bone attachment and bone graft incorporation through in vivo studies. The addition of an optimal amount of BG to Ti-6Al-4V leads to a lower elastic modulus of the ceramic-metal composite material, effectively reducing the stress-shielding effects. Pedicle screw implants with optimal shape design and made of the composite material of Ti-6Al-4V doped with BG fabricated through additive manufacturing exhibit greater osseointegration and a more rapid bone volume fraction during the fracture healing process 120 days after implantation, per in vivo studies.

3 June 2022 in Preprints.org
Verified
Preprint
Open access
PDF file
Giam TrinhGiam Trinh
Giam Trinh
HSHao-Chiang Shao
Hao-Chiang Shao
KHKevin Li-Chun Hsieh
Kevin Li-Chun Hsieh
CLChing-Yu Lee
Ching-Yu Lee
HLHsiao-Wei Liu
Hsiao-Wei Liu
THTsung-Jen Huang
Tsung-Jen Huang
A common spinal condition, spondylolisthesis is the presence of a relative back or forth displacement between the upper and lower vertebra due to one vertebra being oriented away from the smooth curvature of a normal spine. Aging-related illnesses such as degenerative spondylolisthesis are especially burdensome on social welfare and health-care systems in an aging society, especially radiologists and clinical physicians. Therefore, we proposed a computer aided diagnosis algorithm, named LumbarNet, for vertebral slippage detection on clinical X-ray images. Collaborating with i) a P-grade, ii) a piecewise slope detection scheme, and iii) a dynamic shift detection routine, LumbarNet was thus specialized for analyzing complex structural patterns in lumbar spine X-ray images and outcompeted other U-Net based methods. Extensive experiments on lumbar spine X-ray images in standard clinical practices showed that LumbarNet achieved a mean intersection over union value of 0.88 in vertebral region detection and an accuracy of 88.83% in vertebral slippage detection.

22 December 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
ABAnh Tuan Bui
Anh Tuan Bui
HLHieu Le
Hieu Le
THTung Thanh Hoang
Tung Thanh Hoang
Giam TrinhGiam Trinh
Giam Trinh
HSHao-Chiang Shao
Hao-Chiang Shao
MWMeng-Huang Wu
Meng-Huang Wu
Transforaminal lumbar interbody fusion (TLIF) is a commonly used technique for treating lumbar degenerative diseases. In this study, we developed a fully computer-supported pipeline to predict both the cage height and the degree of lumbar lordosis subtraction from the pelvic incidence (PI-LL) after TLIF surgery, utilizing preoperative X-ray images. The automated pipeline comprised two primary stages. First, a deep learning model was employed to extract essential features from X-ray images. Subsequently, five machine learning algorithms were trained to identify the optimal models to predict interbody cage height and postoperative PI-LL. LASSO regression and support vector regression demonstrated superior performance in predicting interbody cage height and postoperative PI-LL, respectively. For cage height prediction, the root mean square error (RMSE) was calculated as 1.01, and the model achieved the highest accuracy at a height of 12 mm, with exact prediction achieved in 54.43% (43/79) of cases. In most of the remaining cases, the prediction error of the model was within 1 mm. Additionally, the model demonstrated satisfactory performance in predicting PI-LL, with an RMSE of 5.19 and an accuracy of 0.81 for PI-LL stratification. In conclusion, our results indicate that machine learning models can reliably predict interbody cage height and postoperative PI-LL.

1 December 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
ABAnh Tuan Bui
Anh Tuan Bui
HLHieu Le
Hieu Le
THTung Thanh Hoang
Tung Thanh Hoang
Giam TrinhGiam Trinh
Giam Trinh
HSHao-Chiang Shao
Hao-Chiang Shao
MWMeng-Huang Wu
Meng-Huang Wu
Transforaminal lumbar interbody fusion (TLIF) is a commonly used technique for treating lumbar degenerative diseases. Here, we developed a fully computer-supported pipeline to predict the cage height and the degree of lumbar lordosis subtraction from the pelvic incidence (PI-LL) after TLIF surgery through preoperative X-ray images. The automated pipeline included two primary stages. First, a deep learning model was used to extract essential features from X-ray images. Second, five machine learning algorithms were trained to identify the optimal models to predict the interbody cage height and postoperative PI-LL. Lasso regression and support vector regression exhibited superior performance for predicting the interbody cage height and postoperative PI-LL, respectively. For cage height prediction, the root mean square error (RMSE) was calculated as 1.01, and the model achieved the highest accuracy at a height of 12 mm, with exact prediction achieved in 54.43% (43/79) of cases. In most of the remaining cases, the prediction error of the model was within 1 mm. In addition, the model demonstrated adequate performance for predicting PI-LL, with an RMSE of 5.19 and an accuracy of 0.81 for PI-LL stratification. In conclusion, the interbody cage height and postoperative PI-LL can be reliably predicted using artificial intelligence and ML models.