Mustafa Istanbullu

Dr. Mustafa Istanbullu

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MIMustafa Istanbullu
Mustafa Istanbullu
MAMutlu Avci
Mutlu Avci
Impedance measurement has been widely used as an effective indicator for characterizing samples. Traditional high accuracy impedance analyzers are complicated, expensive, and non-portable. Many kinds of research require low cost, portable, and high precision impedance analyzer devices. AD5933 impedance analyzer integrated circuit has been popularly used for fulfilling these requirements. There are many successful applications of the AD5933 integrated circuit; however, the most significant drawback is nonlinear calibration requirements for high precision measurement in a specified range. The calibration and unknown impedances must be close enough to each other for better measurement accuracy. In the literature, calibration impedance arrays increasing the complexity and processing time are commonly used for high accuracy measurements. In this study, an artificial neural network-based signal post-processing algorithm is proposed to overcome the calibration requirements of the AD5933 integrated circuit, which requires different impedances for different ranges. In the literature, a neural network-based solution has not been applied to this phenomenon. An application specific artificial neural network topology is developed and trained for high precision impedance measurement using a fixed calibration impedance. The proposed measurement system is designed for operating in the range of nominal skin impedance. The average mean square error of measurements is obtained as 0.206%. Although a fixed calibration resistance is used, the proposed signal post-processing approach significantly improved the measurement accuracy of the AD5933 integrated circuit. The high accuracy measurement results prove the effectiveness of the proposed measurement system. The developed system offers portable, simple, and low cost high precision impedance analyzer.

11 December 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AYAli Cem Yakaryilmaz
Ali Cem Yakaryilmaz
Ana PilipovićAna Pilipović
Ana Pilipović
MBMustafa İlteriş Bıçak
Mustafa İlteriş Bıçak
MIMustafa Istanbullu
Mustafa Istanbullu
SKSinan Keyinci
Sinan Keyinci
Mustafa OzcanliMustafa Ozcanli
Mustafa Ozcanli
In this study, a battery case was developed using a 3D (three dimensional)-printed composite of hexagonal boron nitride (hBN) and polylactic acid (PLA) to enhance the thermal performance of lithium-ion battery (LiB) modules. A 10 wt.% amount of hBN was incorporated into the PLA matrix to improve the composite’s thermal conductivity while maintaining electrical insulation. A 3S2P (3 series and 2 parallel) battery configuration was initially evaluated based on the results of a baseline study for comparison and subsequently subjected to a newly developed test procedure to assess the thermal behavior of the designed case under identical environmental conditions. Initially, X-ray diffraction (XRD) and scanning electron microscopy (SEM) analyses were utilized for material characterization, and their results verified the successful integration of hBN by confirming its presence in the hBN-PLA composite. In thermal tests, experimental results revealed that the fabricated hBN-PLA composite battery case significantly enhanced heat conduction and reduced surface temperature gradients compared to the previous baseline study with no case. Specifically, the maximum cell temperature (Tmax) decreased from 48.54 °C to 45.84 °C, and the temperature difference (ΔT) between the hottest and coldest cells was reduced from 4.65 °C to 3.75 °C, corresponding to an improvement of approximately 20%. A 3S2P LiB module was also tested under identical environmental conditions using a multi-cycle charge–discharge procedure designed to replicate real electric vehicle (EV) operation. Each cycle consisted of sequential low and high discharge zones with gradually increased current values from 2 A to 14 A followed by controlled charging and rest intervals. During the experimental procedure, the average ΔT between the cells was recorded as 2.38 °C, with a maximum value of 3.50 °C. These results collectively demonstrate that the 3D-printed hBN-PLA composite provides an effective and lightweight passive cooling solution for improving the thermal stability and safety of LiB modules in EV applications.

16 June 2025 in Journal of Biomedical Materials Research Part A
Verified
Journal Article
Open access
OIO. Burak Istanbullu
O. Burak Istanbullu
GAGulsen Akdogan
Gulsen Akdogan
HYHalis Yilmaz
Halis Yilmaz
MIMustafa Istanbullu
Mustafa Istanbullu
Cardiovascular diseases cause the highest global mortality rates and are often treated with surgical interventions such as stent or vascular plug placement. However, in‐stent restenosis develops over time depending on the material composition and interactions with body fluids. Current strategies to address restenosis include balloon angioplasty or placing a secondary stent at the same site. A key concern with overlapping stents is the increasing risk of galvanic corrosion, as most cardiovascular stents have metallic composition. This study examines galvanic corrosion rates in different vascular stent and plug combinations using electrochemical corrosion characterization techniques. Three metallic vascular specimens with varying compositions are evaluated. The specimens are immersed in simulated body fluid at 37°C under individual and overlapping conditions. Electrochemical impedance spectroscopy and current density measurements, conducted via potentiostat, provide insights into the corrosion behavior of each specimen configuration. Additionally, inductively coupled plasma mass spectrometry quantifies metal ion release through SBF samples. Results show that combining dissimilar materials in overlapping placements significantly increases galvanic corrosion and metal ion release. The corrosion current density (icorr) significantly increased from 11.75 μA/cm2 in the individual bare‐metallic stent to 522.3 μA/cm2 in the stent‐on‐plug configuration. A similar increase was observed in the stent‐on‐stent configuration, with an icorr of 132.6 μA/cm2. These results corresponded with notable decreases in electrochemical impedance and polarization resistance, measured as low as 0.039 kΩ (ZT) and 0.057 kΩ cm2 (RP) for the stent‐on‐plug system. Consequently, the calculated corrosion rate escalated to 2254 μm/year, with a mass loss reaching 42.22 mg/cm2·year. ICP‐MS analysis supported these findings, showing the highest levels of metal ion release in the stent‐on‐plug configuration, with 23.86 ppm of Ni and 0.41 ppm of Cr. These findings highlight the importance of stent‐material selection in reducing corrosion‐related complications. Implementing material‐specific strategies in secondary stent placement can lower the risks of inflammatory host response, stent failure, and their long‐term effects.

5 April 2019 in Instrumentation Science & Technology
Verified
Journal Article
Closed access
MIMustafa Istanbullu
Mustafa Istanbullu
MAMutlu Avci
Mutlu Avci
Standard electrodes for electrophysiological signal acquisition in clinical applications such as electrocardiography or electromyography require the use of electrolytic gel and skin abrasion for better electrical interface between electrode and skin. Since gel dries out over a period of time, signal deterioration takes place on long duration with wet electrodes. Dry electrodes are promising alternative for long duration recording; nevertheless, they suffer from high contact impedance and motion artifacts. The proposed work introduces a novel multi-walled carbon nanotube (MWCNT) modified metal oxide semiconductor field effect transistor (MOSFET) based electrode for electrophysiological measurements on human skin. Vertically aligned metallic MWCNTs grown on the gate of MOSFETs form the contact surface of the electrode. MWCNTs penetrate the outer layer of skin for stable and improved electrical contact without the gel. The proposed electrode utilizes advantages of the MOSFET such as direct charge–current conversion, insulation between skin and instrumentation unit, and low noise pre-amplification of electrophysiological signals. Electrical equivalent of MWCNTs, design, and microfabrication of convenient MOSFET are reported. MOSFET parameters are obtained from technology computer-aided design simulation environment and combined with MWCNT parameters in the simulation program for integrated circuits emphasis. Simulated results of the proposed electrode exhibited lower contact impedance and high quality signal capture with respect to wet electrodes. The results show that the proposed electrode can be used for long duration recording of biopotentials with very high stable performance.

1 April 2012
Verified
Conference Paper
Closed access
MIMustafa Istanbullu
Mustafa Istanbullu
MAMusa Aydin
Musa Aydin
RBRıfat Benveni̇ste
Rıfat Benveni̇ste
OUOsman Nuri Ucan
Osman Nuri Ucan
RJRachid Jennane
Rachid Jennane
In the last decade, osteoporotic fractures became one of the most serious problems in public health. The life risk of suffering of an osteoporotic fracture is estimated to be 30% for 50 years old and in postmenopausal period woman. Early diagnosis is quite important for osteoporosis. A fall can be easily result in a fracture; these are common in the hip, at the neck of the femur, the wrist and the spine, if it's not treated sequences on time. Be inspiring from this problem we aimed to build up an image processing method for helping to early diagnosis. In this study we obtained features via wavelet transform from Computerized Tomography images. Classification is achieved by Artificial Neural Networks (ANN) and Support Vector Machines (SVM). As a result for ANN, we accomplished 70% correct osteoporosis classification from early period images. SVM classification increased the accuracy and we have reached up 86% correct classification. These successful results make a significant contribution to early diagnosis of osteoporosis.

16 July 2025 in Physical and Engineering Sciences in Medicine
Verified
Journal Article
Closed access
PDF file
BOBusra Oguzhan
Busra Oguzhan
MIMustafa Istanbullu
Mustafa Istanbullu