Mabel Juliana Noguera

Ms. Mabel Juliana Noguera

MSc in Electronic Engineering, Universidad de los Andes
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2019 in Biosensors
Verified
Journal Article
Open access
PDF file
ACAna Lucía Campaña
Ana Lucía Campaña
SGSergio Florez Gonzalez
Sergio Florez Gonzalez
MNMabel Juliana Noguera
Mabel Juliana Noguera
OFOlga Fuentes
Olga Fuentes
Paola Ruiz PuentesPaola Ruiz Puentes
Paola Ruiz Puentes
Johann F. OsmaJohann F. Osma
Johann F. Osma
Emerging water pollutants such as pharmaceutical contaminants are suspected to induce adverse effects to human health. These molecules became worrisome due to their increasingly high concentrations in surface waters. Despite this alarming situation, available data about actual concentrations in the environment is rather scarce, as it is not commonly monitored or regulated. This is aggravated even further by the absence of portable and reliable methods for their determination in the field. A promising way to tackle these issues is the use of enzyme-based and miniaturized biosensors for their electrochemical detection. Here, we present an overview of the latest developments in amperometric microfluidic biosensors that include, modeling and multiphysics simulation, design, manufacture, testing, and operation methods. Different types of biosensors are described, highlighting those based on oxidases/peroxidases and the integration with microfluidic platforms. Finally, issues regarding the stability of the biosensors and the enzyme molecules are discussed, as well as the most relevant approaches to address these obstacles.

15 May 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
PTPaula Peñaranda Trujillo
Paula Peñaranda Trujillo
MNMabel Juliana Noguera
Mabel Juliana Noguera
SGSergio Florez Gonzalez
Sergio Florez Gonzalez
JHJohana Husserl
Johana Husserl
NONancy Ornelas-Soto
Nancy Ornelas-Soto
Johann F. OsmaJohann F. Osma
Johann F. Osma
In this work, the design, manufacture, and testing of three different magnetic microreactors based on torus geometries (i.e., one-loop, two-horizontal-loop, and two-vertical-loop) is explored to increase the enzyme-based transformation of dyes by laccase bio-nanocomposites, improve the particle suspension, and promote the interaction of reagents. The laccase enzyme was covalently immobilized on amino-terminated silanized magnetite nanoparticles (laccase-magnetite). The optimal configuration for the torus microreactor and the applied magnetic field was evaluated in silico with the aid of the CFD and particle tracing modules of Comsol Multiphysics®. Eriochrome Black T (EBt) dye was tested as a biotransformation model at three different concentrations, i.e., 5 mg/L, 10 mg/L, and 20 mg/L. Phenol oxidation/removal was evaluated on artificial wastewater and real wastewater. The optimal catalytic performance of the bionanocomposite was achieved in the range of pH 4 to 4.5. A parabolic movement on the particles along the microchannels was induced by the magnetic field, which led to breaking the stability of the laminar flow and improving the mixing processes. Based on the simulation and experiments conducted with the three geometries, the two-vertical-loop microreactor demonstrated a better performance mainly due to larger dead zones and a longer residence time. Additionally, the overall dye removal efficiencies for this microreactor and the laccase-magnetite bionanocomposite were 98.05%, 93.87%, and 92.74% for the three evaluated concentrations. The maximum phenol oxidation with the laccase-magnetite treatment at low concentration for the artificial wastewater was 79.89%, while its phenol removal efficiency for a large volume of real wastewater was 17.86%. Treatments with real wastewater were carried out with a larger volume, equivalent to 200 biotransformation (oxidation) operating cycles of those carried out with dyes or phenol. Taken together, our results indicate that the novel microreactors introduced here have the potential to process wastewaters rich in contaminant dyes in continuous mode with efficiencies that are attractive for a potential large-scale operation. In this regard, future work will focus on finding the requirements for scaling-up the processes and evaluating the involved environmental impact indexes, economic performance, and different device geometries and processing schemes.

29 January 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
AGAmaimen Guillén-Pacheco
Amaimen Guillén-Pacheco
AAArdila Adame Yeferzon Alexander
Ardila Adame Yeferzon Alexander
MNMabel Juliana Noguera
Mabel Juliana Noguera
ACAna Lucía Campaña
Ana Lucía Campaña
MBMiranda Bejarano
Miranda Bejarano
Johann F. OsmaJohann F. Osma
Johann F. Osma
Magnetite-based nanocomposites are used for biomedical, industrial, and environmental applications. In this study, we evaluated their effects on survival, malformation, reproduction, and behavior in a zebrafish animal model. Nanoparticles were synthesized by chemical coprecipitation and were surface-functionalized with (3-aminopropyl) triethoxysilane (APTES), L-cysteine (Cys), and 3-(triethoxysilyl) propylsuccinic anhydride (CAS). All these nanocomposites were designed for the treatment of wastewater. Zebrafish embryos at 8 h post-fertilization (hpf) and larvae at 4 days post-fertilization (dpf) were exposed to the magnetic nanocomposites Fe3O4 MNP (magnetite), MNP+APTES, MNP+Cys, MNP+APTES+Cys, and MNP+CAS, at concentrations of 1, 10, 100, and 1000 µg/mL. Zebrafish were observed until 13 dpf, registering daily hatching, survival, and malformations. Behavior was tested at 10 dpf for larvae, and reproduction was analyzed later in adulthood. The results showed that the toxicity of the nanocomposites used were relatively low. Exploratory behavior tests showed no significant changes. Reproduction in adults treated during development was not affected, even at concentrations above the OECD recommendation. Given the slight effects observed so far, these results suggest that nanocomposites at the concentrations evaluated here could be a viable alternative for water remediation because they do not affect the long-term survival and welfare of the animals.

21 September 2022 in Molecules
Verified
Journal Article
Open access
PDF file
SOSofía Ortegón
Sofía Ortegón
PTPaula Peñaranda Trujillo
Paula Peñaranda Trujillo
Cristian F. RodríguezCristian F. Rodríguez
Cristian F. Rodríguez
MNMabel Juliana Noguera
Mabel Juliana Noguera
SGSergio Florez Gonzalez
Sergio Florez Gonzalez
Johann F. OsmaJohann F. Osma
Johann F. Osma
This work studied the feasibility of using a novel microreactor based on torus geometry to carry out a sample pretreatment before its analysis by graphite furnace atomic absorption. The miniaturized retention of total arsenic was performed on the surface of a magnetic sorbent material consisting of 6 mg of magnetite (Fe3O4) confined in a very small space inside (20.1 µL) a polyacrylate device filling an internal lumen (inside space). Using this geometric design, a simulation theoretical study demonstrated a notable improvement in the analyte adsorption process on the solid extractant surface. Compared to single-layer geometries, the torus microreactor geometry brought on flow turbulence within the liquid along the curvatures inside the device channels, improving the efficiency of analyte–extractant contact and therefore leading to a high preconcentration factor. According to this design, the magnetic solid phase was held internally as a surface bed with the use of an 8 mm-diameter cylindric neodymium magnet, allowing the pass of a fixed volume of an arsenic aqueous standard solution. A preconcentration factor of up to 60 was found to reduce the typical “characteristic mass” (as sensitivity parameter) determined by direct measurement from 53.66 pg to 0.88 pg, showing an essential improvement in the arsenic signal sensitivity by absorption atomic spectrometry. This methodology emulates a miniaturized micro-solid-phase extraction system for flow-through water pretreatment samples in chemical analysis before coupling to techniques that employ reduced sample volumes, such as graphite furnace atomic absorption spectroscopy.

7 July 2021
Verified
Book Chapter
Open access
PDF file
OFOlga Fuentes
Olga Fuentes
MNMabel Juliana Noguera
Mabel Juliana Noguera
PTPaula Peñaranda Trujillo
Paula Peñaranda Trujillo
SGSergio Florez Gonzalez
Sergio Florez Gonzalez
Juan CruzJuan Cruz
Juan Cruz
Johann F. OsmaJohann F. Osma
Johann F. Osma
The use of micromixers and catalytically active nanocomposites can be an attractive alternative for the treatment of wastewaters from the textile industry, due to their high activity, low consumption of such nanocomposites, short reaction times and the possibility to work under continuous operation. In this study, 6 different designs of micromixers were modeled and evaluated for the treatment of wastewaters. Velocity profiles, pressure drops, and flows were analyzed and compared for the different devices under the same mixing conditions. In addition, Life cycle assessment (LCA) methodology was applied to determine their performance in terms of environmental impact. Considering the high environmental impact of water sources contaminated by dyes from the textile industry, it becomes critically important to determine when the proposed micromixers are a suitable alternative for their remediation. The LCA and operational efficiency studies results shown here provide a route for the design of novel wastewater treatment systems by coupling low-cost and high-performance micromixers.

21 March 2018
Verified
Book Chapter
Open access
PDF file
NLNatalia Lopez-Barbosa
Natalia Lopez-Barbosa
ACAna Lucía Campaña
Ana Lucía Campaña
MNMabel Juliana Noguera
Mabel Juliana Noguera
SGSergio Florez Gonzalez
Sergio Florez Gonzalez
MAMiguel Angel Aroca
Miguel Angel Aroca
Johann F. OsmaJohann F. Osma
Johann F. Osma
Point-of-care devices technology are a promising way towards the recognition of pathogens in early-stage diagnosis, which is critical for the success of inexpensive treatments as opposed to the high costs of managing the disease. The integration of immunoassays with read out circuitry allows the implementation of diagnostic devices for their use by untrained personnel, without compromising reliability. In the following chapter, three different biosensors based on lab-on-a-chip (LoC) and microfluidic technologies were designed, assembled and tested for pathogen diagnosis. The devices allowed the effective detection of the human papilloma virus, Mycobacterium tuberculosis and Chagas parasite in shorter times and with smaller sample volumes than those required by current clinical diagnosis techniques. All devices were benchmarked against commercial techniques in terms of cost and time requirement per test.