Mehmet Rıda Tür

Dr. Mehmet Rıda Tür

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2018 in IEEE Access
Verified
Journal Article
Open access
EHEklas Hossain
Eklas Hossain
Mehmet Rıda TürMehmet Rıda Tür
Mehmet Rıda Tür
Sanjeevikumar PadmanabanSanjeevikumar Padmanaban
Sanjeevikumar Padmanaban
SASelim Ay
Selim Ay
IKImtiaj Khan
Imtiaj Khan
This paper discusses the power quality issues for distributed generation systems based on renewable energy sources such as solar and wind energy. A thorough discussion about power quality issues is conducted here. The paper starts with power quality issues, followed by discussions of basic standards. A comprehensive study of power quality in power systems, including the systems with DC as well as renewable sources is done in this work. Power quality monitoring techniques and possible solutions of power quality issues for power systems are elaborately studied. Then we analyze the methods of mitigation of these problems using custom power devices such as D-STATCOM, UPQC, UPS, TVSS, DVR etc. for micro grid systems. For renewable energy systems, STATCOM can be a potential choice due to its several advantages, whereas spinning reserve can enhance the power quality in traditional systems. Lastly, we study the power quality in DC systems. Simpler arrangement and higher reliability are two main advantages of DC systems though it faces other power quality issues such as instability and poor detection of faults.

24 April 2020 in IEEE Access
Verified
Journal Article
Open access
Mehmet Rıda TürMehmet Rıda Tür
Mehmet Rıda Tür
The main task of distribution systems is to provide acceptable reliability, economic and quality service of electrical power according to the demanded load value. To fulfill this task more accurately, the reliability performance of the distribution system can be performed and measured using a wide variety of indices, which are divided into energy indices and frequency/expectation indices. This study evaluates the reliability indices of a part of the distribution network selected as a model and deals with the selection of the most suitable feeder by connecting energy storage units to the busbars. Using IEEE Standard 1366 reliability indices, historical data from Prosperous Electricity Distribution Company (PEDC), which is used to evaluate reliability based on the 5-year past reliability assessment of the power system (RAPS), was selected. In addition, as an innovation in this application process, energy storage systems (ESS) have been evaluated according to four different network configurations (A-B-C-D) to increase RAPS and achieve more realistic results. Using DigSILENT, ESS-based configurations are designed, comparisons are made, and configuration B is the best result to increase system reliability and the 80E6 feeder is optimal. In addition, reliability changes achieved by network configuration have demonstrated the importance of optimal configuration planning to improve the uninterrupted and sustainable energy quality of the system based on storage technology.

24 March 2020 in IEEE Access
Verified
Journal Article
Open access
HMHalim Mondol
Halim Mondol
Mehmet Rıda TürMehmet Rıda Tür
Mehmet Rıda Tür
Shuvra Prokash BiswasShuvra Prokash Biswas
Shuvra Prokash Biswas
MHMd Kamal Hosain
Md Kamal Hosain
SSShuvangkar Shuvo
Shuvangkar Shuvo
Eklas HossainEklas Hossain
Eklas Hossain
A new three phase multilevel inverter with reduced number of components count is proposed in this paper. This inverter is designed using a single DC source per phase to generate multiple level output voltage which makes it suitable for low and medium voltage applications, including ac-coupled renewables or energy storages. A generalized circuit configuration is shown in this paper following which the number of output voltage level can be increased as per expectation. Although, each element endures the voltage stress equivalent to the input DC voltage, the value of total standing voltage (TSV) is reduced by the utilization of minimized number of components with respect to the number of series connected capacitors. Further, staircase modulation scheme is used to generate the switching signals. Hence, the proposed inverter can be operated at low switching frequency with optimal output current harmonic distortion which decreases switching losses and suppresses power factor falling. In order to validate the theoretical explanations and practical performances of the proposed inverter, the hypothesis is simulated for 9, 13 and 39 output voltage level inverters for three phase with a line voltage total harmonic distortion (THD) of 6.06%, 4.16% and 2.10% respectively in MATLAB/Simulink and a 5-level single phase laboratory prototype is implemented in the laboratory.

25 December 2023 in Electric Power Components and Systems
Verified
Journal Article
Closed access
FÇFevzi Çakmak
Fevzi Çakmak
ZAZafer Aydoğmuş
Zafer Aydoğmuş
Mehmet Rıda TürMehmet Rıda Tür
Mehmet Rıda Tür

1 April 2018
Verified
Conference Paper
Closed access
MWMohammed Wadi
Mohammed Wadi
ASAbdulfetah Shobole
Abdulfetah Shobole
Mehmet Rıda TürMehmet Rıda Tür
Mehmet Rıda Tür
MBMustafa Baysal
Mustafa Baysal
In this paper, fuzzy-based control approach is proposed to control the street lighting systems depending on solar and wind renewable energy sources. The light intensity is controlled according to the battery level and the speed of the wind. Fuzzy Logic Control (FLC) is an efficient technique for solving complex problems with little mathematical equations. The proposed fuzzy controller is designed with MATLAB. The proposed street lighting controller depending on the utility, making the efficient utilization of renewable energy such as solar and wind energy which is very necessary in this energy crisis world and the arising of the environmental pollution concerns. In Turkey, the demand for electric power is growing year after year so; this paper suggests a methodology to cut the electricity bill for the lighting of highways. To show effectiveness and savings of the proposed approach, it is applied to a small section of the lighting system of the environmental highway - in Turkish Çevre Yolu-in Istanbul.

1 October 2018
Verified
Conference Paper
Closed access
MWMohammed Wadi
Mohammed Wadi
MBMustafa Baysal
Mustafa Baysal
ASAbdulfetah Shobole
Abdulfetah Shobole
Mehmet Rıda TürMehmet Rıda Tür
Mehmet Rıda Tür
Operation of closed-ring power distribution systems has various advantages over both meshed-operated and radially-operated systems. Closed-ring system unlike to radial system, the voltage drop is less, achieves high reliability of power on demand since the power is supplied from both ends, and reduces the voltage fluctuation in high loaded areas by using a tie power line. However, the reliability assessment of closed-ring power grids is not a trivial task. Monte Carlo Simulation (MCS) is one of the most famous methods to assess the availability of any power system. However, the most proposed methods are able to evaluate the reliability of radial and open-ring grids. This paper developed the best known MCS method to assess the reliability of closed-ring grids by integrating the total loss of continuity (TLOC) definition into the MCS. The developed method is called modified Monte Carlo Simulation (MMCS) method. The MMCS is tested by using Roy Billinton Test System (RBTS) buses 2 and 4. The obtained results confirm the correctness of the proposed method. Therefore, MMCS method is appropriate to assess the reliability of both simple and complicated closed-ring systems.