Nabil Yassine

Dr. Nabil Yassine

School of Engineering, Computing and Mathematics, Oxford Brookes University, Oxford, Oxfordshire, UK
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2018 in Analog Integrated Circuits and Signal Processing
Verified
Journal Article
Open access
PDF file
RNRajasekhar Nagulapalli
Rajasekhar Nagulapalli
KHKhaled Hayatleh
Khaled Hayatleh
SBSteve Barker
Steve Barker
SZSaddam Zourob
Saddam Zourob
NYNabil Yassine
Nabil Yassine
ATAmr Tammam
Amr Tammam
A compact high gain current mode instrumentation amplifier (IA) has been proposed for biomedical imaging applications. Conventional IAs rely on several matching resistors which occupies a lot of silicon area, the input and output common mode voltages are exactly same and the maximum applied signal amplitude is limited by internal node voltage swings. The present proposal eliminates the need for matching resistors by processing signals in the current mode. Hence input amplitudes are no longer limited by the voltage headroom and input and output common-mode voltages can be independent. An amplifier with a differential gain greater than 52 dB and a common mode rejection ratio greater than 120 dB has been implemented in 65 nm CMOS Technology and Post layout simulations were presented. The total circuit occupies 4500 μm2 silicon area and circuit consumes ~ 260 μA from 1.8 V power supply.

8 March 2018 in Analog Integrated Circuits and Signal Processing
Verified
Journal Article
Open access
PDF file
RNRajasekhar Nagulapalli
Rajasekhar Nagulapalli
KHKhaled Hayatleh
Khaled Hayatleh
SBSteve Barker
Steve Barker
SZSaddam Zourob
Saddam Zourob
NYNabil Yassine
Nabil Yassine
The performance requirement of an operational trans-conductance amplifier (OTA) for the high gain and low power neural recording frontend has been addressed in this paper. A novel split differential pair technique is proposed to improve the gain of the OTA without any additional bias current requirements. The design demonstrates a significant performance enhancement when compared to existing techniques, such as gain-boosting and recycling. A qualitative and quantitative treatment is presented to explore the impact of the split ratio on the performance parameters of gain, bandwidth, and linearity. A prototype implemented in TSMC 65 nm CMOS technology achieved 68 dB open loop-gain (13 dB higher than the conventional circuit) and a 17 kHz 3-dB bandwidth. A linearity of − 62 dB has been achieved with 7 mV pk–pk signal at the input. The circuit operates from a 1 V supply and draws 0.6 uA static current. The prototype occupies 3300 um2 silicon area.

1 March 2017
Verified
Conference Paper
Closed access
RNR. Nagulapalli
R. Nagulapalli
KHK. Hayatleh
K. Hayatleh
SBS. Barker
S. Barker
SZS. Zourob
S. Zourob
NYNabil Yassine
Nabil Yassine
SSSriadibhatala Sridevi
Sriadibhatala Sridevi
In this paper a microwatt low voltage bandgap reference suitable for the bio-medical application. The Present technique relies on the principle of generating CTAT and PTAT without using any (Bipolar Junction Transistor) BJT and adding them with a proper scaling factor for minimal temperature sensitive reference voltage. Beta multiplier reference circuit has been explored to generate CTAT and PTAT. Implemented in 45nm CMOS technology and simulated with Spectre. Simulation results shows that the proposed reference circuit exhibits 1.2% variation at nominal 745mV output voltage. The circuit consumes 16uW from 0.8V supply and occupying 0.004875mm2 silicon area.

26 September 2019 in Journal of Circuits, Systems and Computers
Verified
Journal Article
Open access
PDF file
RNR. Nagulapalli
R. Nagulapalli
KHKhaled Hayatleh
Khaled Hayatleh
SBS. Barker
S. Barker
BYBEDDIAF YASSINE
BEDDIAF YASSINE
SZS. Zourob
S. Zourob
NYNabil Yassine
Nabil Yassine
This paper explains the hidden positive feedback in a two-stage fully differential amplifier through external feedback resistors and possible DC latch-up during the amplifier start-up. The biasing current selection among the cascade branches has been explained intuitively, with reference to previous literature. To avoid the latch-up problem, irrespective of the transistor bias currents, a novel hysteresis-based start-up circuit is proposed. An 87[ ]dB, 250[ ]MHz unity gain bandwidth amplifier has been developed in 65[ ]nm CMOS Technology and post-layout simulations demonstrate no start-up failures out of 1000 Monte-Carlo (6-Sigma) simulations. The circuit draws 126[ ][ ]A from a 1.2[ ]V supply and occupies the 2184[ ][ ]m2 area.

2 October 2021 in International Journal of Electronics Letters
Verified
Journal Article
Open access
RNR. Nagulapalli
R. Nagulapalli
NYNabil Yassine
Nabil Yassine
SBS. Barker
S. Barker
PGP Georgiou
P Georgiou
KHKhaled Hayatleh
Khaled Hayatleh
In this paper, a low voltage bandgap reference circuit has been proposed. The introduction of a modified beta multiplier bias circuit decreased the mismatch caused by the PMOS transistors opamp contribution. By shifting the fixed resistors to the NMOSs drain side, the beta multiplier bias minimised threshold mismatch between the two NMOS transistors. A 200-point MC simulation showed a 0.9 mV standard deviation, with a 0.34% accuracy. The simulated temperature coefficient was 64 ppm/0C. The proposed circuit consumed 5.04 µW of power from a 0.45 V power supply voltage. A prototype was implemented in 65 nm CMOS technology occupying a 2888 µm2 silicon area, with the nominal value of the reference at 261 mV.

8 March 2018 in Analog Integrated Circuits and Signal Processing
Verified
Journal Article
Open access
PDF file
SZSaddam Zourob
Saddam Zourob
KHKhaled Hayatleh
Khaled Hayatleh
SBSteve Barker
Steve Barker
RNRajasekhar Nagulapalli
Rajasekhar Nagulapalli
NYNabil Yassine
Nabil Yassine
JLJohn Lidgey
John Lidgey
Capturing a near-perfect, artefact free signal is an ideal of biomedicine. However, this depends on the removal of different types of artefact, all of which can be considered unwanted noise on the desired signal. Failure to remove artefacts could lead to a clinical misinterpretation of the results. All medical equipment such as electrocardiogram systems which use electrodes attached to patients suffer from artefacts, with effects ranging from minor blurring to significant distortion of the output signal(s). For this reason, it is important to identify how artefacts can influence the output signal. In this paper, we propose a new technique to detect and minimise movement artefacts using strain gauges embedded into the electrodes.