Natural and synthetic fibres have emerged in high demand due to their excellent properties. Natural fibres have good mechanical properties and are less expensive, making them a viable substitute for synthetic fibers. Owing to certain drawbacks such as their inconsistent quality and hydrophilic nature, researchers focused on incorporating these two fibres as an alternative to improve the limitations of the single fibre. This review focused on the interply hybridisation of natural and synthetic fibres into composites. Natural fibres and their classifications are discussed. The physical and mechanical properties of these hybrid composites have also been included. A full discussion of the mechanical properties of natural/synthetic fibre hybrid composites such as tensile, flexural, impact, and perforation resistance, as well as their failure modes, is highlighted. Furthermore, the applications and future directions of hybrid composites have been described in details.
Natural and synthetic fibres are in high demand due to their superior properties. Natural fibres are less expensive and lighter as compared to synthetic fibres. Synthetic fibres have drawn much attention, especially for their outstanding properties, such as durability, and stability. The hybridisation between natural and synthetic fibres composite are considered as an alternative to improve the current properties of natural and synthetic fibres. Therefore, this study aimed to determine the physical and mechanical properties of pineapple leaf fibre (PALF) and Kevlar reinforced unsaturated polyester (UP) hybrid composites. The PALF/Kevlar hybrid composites were fabricated by using hand layup method utilising unsaturated polyester as the matrix. These composites were laid up to various laminated configurations, such as [PKP]s, [PPK]s, [KPP]s, [KKP]s, [PPP]s and [KKK]s, whereby PALF denoted as P and Kevlar denoted as K. Next, they were cut into size and dimensions according to standards. Initially, the density of PALF/Kevlar reinforced unsaturated polyester were evaluated. The highest density result was obtained from [KKK]s, however, the density of hybrid composites was closely indistinguishable. Next, moisture absorption behaviour and its effects on the PALF/Kevlar reinforced unsaturated polyester were investigated. The water absorption studies showed that the hybridisation between all PALF and Kevlar specimens absorbed moisture drastically at the beginning of the moisture absorption test and the percentage of moisture uptake increased with the volume fraction of PALF in the samples. The tensile test indicated that all specimens exhibited nonlinear stress-strain behaviour and shown a pseudo-ductility behaviour. [KKP]s and [KPK]s hybrid composites showed the highest tensile strength and modulus. The flexural test showed that [KPK]s had the highest flexural strength of 164.0 MPa and [KKP]s had the highest flexural modulus of 12.6 GPa. In terms of the impact strength and resistance, [KKP]s outperformed the composite laminates. According to SEM scans, the hybrid composites demonstrated a stronger interfacial adhesion between the fibres and matrix than pure PALF composite.
22 December 2015 in IOP Conference Series: Materials Science and Engineering
This study presents the response of kenaf/epoxy corrugated sandwich structure during quasi-static test. Force-displacements curves have been deducted to determine the deformation pattern and collapse behavior of the structure. Kenaf/epoxy sandwich structures skins fabricated by using hand layup technique and the corrugated core were moulded by using steel mould. Different thicknesses of corrugated core web with two sizes of kenaf fibers were used. The corrugated core is then bonded with the skins by using poly-epoxy resin and has been cut into different number of cells. The specimens then tested under tensile and compression at different constant speeds until the specimens fully crushed. Tensile tests data showed the structure can be considered brittle when it breaking point strain, ε less than 0.025. In compression test, the specimens fail due to dominated by stress concentration that initiated by prior cracks. Also, the specimens with more number of cells and thicker core web have higher strength and the ability to absorb higher energy.
25 May 2015 in Jurnal Teknologi (Sciences & Engineering)
Construction activities generate construction noise may cause noise annoyance among the public residents. The aim of this study is to investigate the noise annoyance level due to the sound pressure levels and the distances from the construction sites. Three public resident areas around Johor which located near to the construction sites have been selected. Two important indicators such as sound pressure levels and distances between the receiver and the noise sources were measured. 42 questionnaires were randomly distributed to the public residents who live near to the construction sites. The results showed that all respondent have different annoyance levels due to the construction noise. The sound pressure levels received by the public residents are increasing with the decreasing of the distance between the receiver and the noise sources. Thus, the relationship of noise annoyance levels is directly proportional to the sound pressure levels produced from construction sites. Meanwhile, the noise annoyance levels are decreasing with the increasing of the distances. As a conclusion, the public residents who live nearer to the construction sites suffered from a high noise annoyance level as expected.