21 August 2016 in International Journal of Hyperthermia
Verified
Journal Article
Closed access
VLVanni Lopresto
Vanni Lopresto
RPR. Pinto
R. Pinto
Laura FarinaLaura Farina
Laura Farina
Marta CavagnaroMarta Cavagnaro
Marta Cavagnaro
Microwave thermal ablation (MTA) is a minimally invasive therapeutic technique aimed at destroying pathologic tissues through a very high temperature increase induced by the absorption of an electromagnetic field at microwave (MW) frequencies. Open problems, which are delaying MTA applications in clinical practice, are mainly linked to the extremely high temperatures, up to 120 °C, reached by the tissue close to the antenna applicator, as well as to the ability of foreseeing and controlling the shape and dimension of the thermally ablated area. Recent research was devoted to the characterisation of dielectric, thermal and physical properties of tissue looking at their changes with the increasing temperature, looking for possible developments of reliable, automatic and personalised treatment planning. In this paper, a review of the recently obtained results as well as new unpublished data will be presented and discussed.

17 October 2014 in International Journal of Hyperthermia
Verified
Journal Article
Closed access
Laura FarinaLaura Farina
Laura Farina
NWNoam Weiss
Noam Weiss
YNYitzhak Nissenbaum
Yitzhak Nissenbaum
MCMarta Cavagnaro
Marta Cavagnaro
VLVanni Lopresto
Vanni Lopresto
SGS. Nahum Goldberg
S. Nahum Goldberg
The aim of this study was to characterise changes in tissue volume during image-guided microwave ablation in order to arrive at a more precise determination of the true ablation zone. The effect of power (20-80 W) and time (1-10 min) on microwave-induced tissue contraction was experimentally evaluated in various-sized cubes of ex vivo liver (10-40 mm ± 2 mm) and muscle (20 and 40 mm ± 2 mm) embedded in agar phantoms (N = 119). Post-ablation linear and volumetric dimensions of the tissue cubes were measured and compared with pre-ablation dimensions. Subsequently, the process of tissue contraction was investigated dynamically during the ablation procedure through real-time X-ray CT scanning. Overall, substantial shrinkage of 52-74% of initial tissue volume was noted. The shrinkage was non-uniform over time and space, with observed asymmetry favouring the radial (23-43 % range) over the longitudinal (21-29%) direction. Algorithmic relationships for the shrinkage as a function of time were demonstrated. Furthermore, the smallest cubes showed more substantial and faster contraction (28-40% after 1 min), with more considerable volumetric shrinkage (>10%) in muscle than in liver tissue. Additionally, CT imaging demonstrated initial expansion of the tissue volume, lasting in some cases up to 3 min during the microwave ablation procedure, prior to the contraction phenomenon. In addition to an asymmetric substantial shrinkage of the ablated tissue volume, an initial expansion phenomenon occurs during MW ablation. Thus, complex modifications of the tissue close to a radiating antenna will likely need to be taken into account for future methods of real-time ablation monitoring.

21 June 2017 in Medical Engineering & Physics
Verified
Journal Article
Closed access
VLVanni Lopresto
Vanni Lopresto
RPRosanna Pinto
Rosanna Pinto
Laura FarinaLaura Farina
Laura Farina
MCMarta Cavagnaro
Marta Cavagnaro
Microwave thermal ablation (MTA) therapy for cancer treatments relies on the absorption of electromagnetic energy at microwave frequencies to induce a very high and localized temperature increase, which causes an irreversible thermal damage in the target zone. Treatment planning in MTA is based on experimental observations of ablation zones in ex vivo tissue, while predicting the treatment outcomes could be greatly improved by reliable numerical models. In this work, a fully dynamical simulation model is exploited to look at effects of temperature-dependent variations in the dielectric and thermal properties of the targeted tissue on the prediction of the temperature increase and the extension of the thermally coagulated zone. In particular, the influence of measurement uncertainty of tissue parameters on the numerical results is investigated. Numerical data were compared with data from MTA experiments performed on ex vivo bovine liver tissue at 2.45GHz, with a power of 60W applied for 10min. By including in the simulation model an uncertainty budget (CI=95%) of ±25% in the properties of the tissue due to inaccuracy of measurements, numerical results were achieved in the range of experimental data. Obtained results also showed that the specific heat especially influences the extension of the thermally coagulated zone, with an increase of 27% in length and 7% in diameter when a variation of -25% is considered with respect to the value of the reference simulation model.

20 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JCJeantide Said Camilleri
Jeantide Said Camilleri
LFLourdes Farrugia
Lourdes Farrugia
Sergio CurtoSergio Curto
Sergio Curto
DRDario Rodrigues
Dario Rodrigues
Laura FarinaLaura Farina
Laura Farina
CHARLES SAMMUTCHARLES SAMMUT
CHARLES SAMMUT
Electromagnetic thermal therapies for cancer treatment, such as microwave hyperthermia, aim to heat up a targeted tumour site to temperatures within 40 and 44 °C. Computational simulations used to investigate such heating systems employ the Pennes’ bioheat equation to model the heat exchange within the tissue, which accounts for several tissue properties: density, specific heat capacity, thermal conductivity, metabolic heat generation rate, and blood perfusion rate. We present a review of these thermal and physiological properties relevant for hyperthermia treatments of breast including fibroglandular breast, fatty breast, and breast tumours. The data included in this review were obtained from both experimental measurement studies and estimated properties of human breast tissues. The latter were used in computational studies of breast thermal treatments. The measurement methods, where available, are discussed together with the estimations and approximations considered for values where measurements were unavailable. The review concludes that measurement data for the thermal and physiological properties of breast and tumour tissue are limited. Fibroglandular and fatty breast tissue properties are often approximated from those of generic muscle or fat tissue. Tumour tissue properties are mostly obtained from approximating equations or assumed to be the same as those of glandular tissue. We also present a set of reliable data, which can be used for more accurate modelling and simulation studies to better treat breast cancer using thermal therapies.

20 July 2016 in International Journal of Hyperthermia
Verified
Journal Article
Closed access
CAClaudio Amabile
Claudio Amabile
Laura FarinaLaura Farina
Laura Farina
VLVanni Lopresto
Vanni Lopresto
RPRosanna Pinto
Rosanna Pinto
SCSimone Cassarino
Simone Cassarino
MCMarta Cavagnaro
Marta Cavagnaro
Purpose: The aim of this study was to develop a predictive model of the shrinkage of liver tissues in microwave ablation. Methods: Thirty-seven cuboid specimens of ex vivo bovine liver of size ranging from 2 cm to 8 cm were heated exploiting different techniques: 1) using a microwave oven (2.45 GHz) operated at 420 W, 500 W and 700 W for 8 to 20 min, achieving complete carbonisation of the specimens, 2) using a radiofrequency ablation apparatus (450 kHz) operated at 70 W for a time ranging from 6 to 7.5 min obtaining white coagulation of the specimens, and 3) using a microwave (2.45 GHz) ablation apparatus operated at 60 W for 10 min. Measurements of specimen dimensions, carbonised and coagulated regions were performed using a ruler with an accuracy of 1 mm. Based on the results of the first two experiments a predictive model for the contraction of liver tissue from microwave ablation was constructed and compared to the result of the third experiment. Results: For carbonised tissue, a linear contraction of 31 ± 6% was obtained independently of the heating source, power and operation time. Radiofrequency experiments determined that the average percentage linear contraction of white coagulated tissue was 12 ± 5%. The average accuracy of our model was determined to be 3 mm (5%). Conclusions: The proposed model allows the prediction of the shrinkage of liver tissues upon microwave ablation given the extension of the carbonised and coagulated zones. This may be useful in helping to predict whether sufficient tissue volume is ablated in clinical practice.

5 December 2018 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
DPDaphne Anne Pollacco
Daphne Anne Pollacco
Laura FarinaLaura Farina
Laura Farina
PWPierre Schembri Wismayer
Pierre Schembri Wismayer
LFLourdes Farrugia
Lourdes Farrugia
CHARLES SAMMUTCHARLES SAMMUT
CHARLES SAMMUT
The aim of this paper was to investigate the correlation between the dielectric properties of biological tissues and their different states of hydration. Measurements were conducted on rat muscle and fat tissues both in vivo and ex vivo, in different states of dehydration through a loss on drying technique. Dielectric parameters were observed as a function of frequency from 500 MHz to 50 GHz by utilizing an open-ended coaxial probe at constant room temperature of 25° C. By observing which dehydration fractions fall within in vivo values, it was deduced that ex vivo samples are reliable in representing the dielectric parameters of in vivo samples, under certain controlled hydration conditions whereas, further analysis should be conducted for tissue characterized by low water content.