Obhuli Chandran Madhivanan

Dr. Obhuli Chandran Madhivanan

Medical Imaging Technology, Manipal Academy of Higher Education, Manipal, India
orcid
Researcher, Medical Radiology and Imaging Technology

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2024 in F1000Research
Verified
Journal Article
Open access
PDF file
Obhuli Chandran MadhivananObhuli Chandran Madhivanan
Obhuli Chandran Madhivanan
SPSaikiran Pendem
Saikiran Pendem
PSPriya Pattath Sankaran
Priya Pattath Sankaran
CCCijo Chacko
Cijo Chacko
D.Dr. Priyanka .
Dr. Priyanka .
RKRajagopal Kadavigere
Rajagopal Kadavigere
Background The most recent advances in Computed Tomography (CT) image reconstruction technology are Deep learning image reconstruction (DLIR) algorithms. Due to drawbacks in Iterative reconstruction (IR) techniques such as negative image texture and nonlinear spatial resolutions, DLIRs are gradually replacing them. However, the potential use of DLIR in Head and Chest CT has to be examined further. Hence, the purpose of the study is to review the influence of DLIR on Radiation dose (RD), Image noise (IN), and outcomes of the studies compared with IR and FBP in Head and Chest CT examinations. Methods We performed a detailed search in PubMed, Scopus, Web of Science, Cochrane Library, and Embase to find the articles reported using DLIR for Head and Chest CT examinations between 2017 to 2023. Data were retrieved from the short-listed studies using Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines. Results Out of 196 articles searched, 15 articles were included. A total of 1292 sample size was included. 14 articles were rated as high and 1 article as moderate quality. All studies compared DLIR to IR techniques. 5 studies compared DLIR with IR and FBP. The review showed that DLIR improved IQ, and reduced RD and IN for CT Head and Chest examinations. Conclusions DLIR algorithm have demonstrated a noted enhancement in IQ with reduced IN for CT Head and Chest examinations at lower dose compared with IR and FBP. DLIR showed potential for enhancing patient care by reducing radiation risks and increasing diagnostic accuracy.

14 March 2023 in Journal of Taibah University Medical Sciences
Verified
Journal Article
Open access
Obhuli Chandran MadhivananObhuli Chandran Madhivanan
Obhuli Chandran Madhivanan
PPPoovitha Shruthi Shruthi P
Poovitha Shruthi Shruthi P
SSSuresh Sukumar
Suresh Sukumar
RKRajagopal Kadavigere
Rajagopal Kadavigere
KBKalyana Chakravarthy Bairapareddy
Kalyana Chakravarthy Bairapareddy
Baskaran ChandrasekaranBaskaran Chandrasekaran
Baskaran Chandrasekaran
High sedentary behaviour is associated with adverse effects on central vascular function and cognitive function. Although interventions to mitigate the adverse effects of workplace sitting are intriguing, evidence of the efficacy of such interventions remains lacking. This randomised cross-over trial was aimed at exploring the effectiveness of prolonged sitting, with or without physical activity breaks, on central, peripheral vascular and cognitive function in adults. Twenty one healthy adults completed 4 h of simulated work conditions in three experimental visits: (1) uninterrupted sitting (SIT); (2) sitting interrupted by 3 min of walking every hour (LIT); and (3) sitting interrupted by 3 min of stair climbing every hour (MIT). Carotid (CA) and superficial femoral artery (SFA) diameter, velocity, shear rate and blood flow were measured with Duplex ultrasound at 50 MHz at three time points (hours 0, 2 and 4), and executive function was assessed with the computer based Eriksen Flanker task every hour. The decreases in reaction time (-30.59%) and accuracy (-10.56%) during SIT conditions were statistically significant, and less of a decrease was observed under LIT and MIT conditions. No significant differences in CA and SFA function were observed with LIT and MIT interventions. Physical activity breaks of varying intensity during prolonged sitting improve reaction time. However, the vascular benefits of physical activity breaks should be confirmed in the future through long term studies in natural environment.

31 August 2024 in Radiography
Verified
Journal Article
Open access
PRPriyanka
Priyanka
RKRajagopal Kadavigere
Rajagopal Kadavigere
SNShailesh S Nayak
Shailesh S Nayak
Obhuli Chandran MadhivananObhuli Chandran Madhivanan
Obhuli Chandran Madhivanan
ASA. Shirlal
A. Shirlal
SPSaikiran Pendem
Saikiran Pendem
Magnetic Resonance Imaging (MRI) has revolutionized the diagnosis and treatment of musculoskeletal disorders. Parallel imaging (PI) and compressed sensing (CS) techniques reduce scan time, but higher acceleration factors decrease image quality. Artificial intelligence has enhanced MRI reconstructions by integrating deep learning algorithms. Therefore, the study aims to review the impact of Artificial intelligence-assisted compressed sensing (AI-CS) and acceleration factors on scan time and image quality in musculoskeletal MRI. Database searches were completed across PubMed, Scopus, CINAHL, Web of Science, Cochrane Library, and Embase to identify relevant articles focusing on the application of AI-CS in musculoskeletal MRI between 2022 and 2024. We utilized the Preferred Reporting Items for Systematic Reviews and Meta-analysis guidelines to extract data from the selected studies. Nine articles were included for the final review, with a total sample size of 730 participants. Of these, seven articles were rated as high, while two articles were considered to be of moderate quality. MRI examination with AI-CS showed scan time reduction of 18.9-38.8% for lumbar spine, 38-40% for shoulder, 54-75% for knee and 53-63% for ankle. AI-CS showed a significant reduction in scan time and improved image quality for 2D and 3D sequences in musculoskeletal MRI compared with PI and CS. Determining the optimal acceleration factor necessary to achieve images with higher image quality compared to traditional PI techniques is required before clinical implementation. Higher acceleration factors currently lead to reduced image scores, although advancements in AI-CS are expected to address the limitation. AI-CS in MRI improves patient care by shortening scan times, reducing patient discomfort and anxiety, and produces high quality images for accurate diagnosis.

10 October 2024 in F1000Research
Verified
Journal Article
Open access
PDF file
AMAli Muhaimil
Ali Muhaimil
SPSaikiran Pendem
Saikiran Pendem
Niranjana SampathilaNiranjana Sampathila
Niranjana Sampathila
PSPriya Pattath Sankaran
Priya Pattath Sankaran
KNKaushik Nayak
Kaushik Nayak
ASAbhijit Shirlal
Abhijit Shirlal
Background Low back pain (LBP), the primary cause of disability, is the most common musculoskeletal disorder globally and the primary cause of disability. Magnetic resonance imaging (MRI) studies are inconclusive and less sensitive for identifying and classifying patients with LBP. Hence, this study aimed to investigate the role of artificial intelligence (AI) models in the prediction of LBP using T2 weighted MRI image of the lumbar spine. Methods This was a prospective case-control study. A total of 200 MRI patients (100 cases and controls each) referred for lumbar spine and whole spine screening were included. The scans were performed using 3.0 Tesla MRI (United Imaging Healthcare). T2 weighted images of the lumbar spine were segmented to extract radiomic features. Machine learning (ML) models, such as random forest, decision tree, logistic regression, K-nearest neighbors, adaboost, and deep learning methods (DL), such as ResNet and GoogleNet, were used, and performance measures were calculated. Results Our study showed that Random forest and AdaBoost are the most reliable ML models for predicting LBP. Random forest showed high performance with area under curve (AUC) values from 0.83 to 0.88 across all lumbar vertebrae and L2-L3, L3-L4, and L4-L5 intervertebral discs (IVDs), with AUCs of 0.88 the highest at L5-S1 IVD (0.92). Adaboost demonstrated high performance at the L2-L5 vertebrae with AUC values of 0.82 to 0.90, with the highest AUC (0.97) at the L5-S1 IVD. Among the DL models, GoogleNet outperformed the other models at 30 epochs with an accuracy of 0.85, followed by ResNet 18 (30 epochs) with an accuracy of 0.84. Conclusion The study demonstrated that ML and DL models can effectively predict LBP from MRI T2 weighted image of the lumbar spine. ML and DL models could also enhance the diagnostic accuracy of LBP, potentially leading to better patient management and outcomes.

9 January 2025 in F1000Research
Verified
Journal Article
Open access
PDF file
RSRiyan Mohamed Sajer
Riyan Mohamed Sajer
SPSaikiran Pendem
Saikiran Pendem
RKRajagopal Kadavigere
Rajagopal Kadavigere
D.Dr. Priyanka .
Dr. Priyanka .
SNShailesh S Nayak
Shailesh S Nayak
VRVarsha Raghu
Varsha Raghu
Introduction Magnetic resonance imaging (MRI) is essential for brain imaging, but conventional methods rely on qualitative contrast, are time-intensive, and prone to variability. Magnetic resonance finger printing (MRF) addresses these limitations by enabling fast, simultaneous mapping of multiple tissue properties like T1, T2. Using dynamic acquisition parameters and a precomputed signal dictionary, MRF provides robust, qualitative maps, improving diagnostic precision and expanding clinical and research applications in brain imaging. Methods Database searches were performed through PubMed, Embase, Scopus, Web of science to identify relevant articles focusing on the application of MR finger printing in the adult brain. We utilized the preferred reporting items for systematic reviews and meta-analysis guidelines to extract data from the selected studies. Results Nine articles were included in the final review, with a total sample size of 332 participants. In healthy brains, notable regional, sex, age, and hemispheric variations were identified, particularly in the corpus callosum and thalamus. MRF effectively differentiated meningioma subtypes, glioma grades, and IDH mutation status, with T2 values providing particularly predictive for glioma classification. In brain metastases, significant relaxometry differences were noted between normal and lesional tissues. For multiple sclerosis, MRF values correlated with clinical and disability measures, distinguishing relapsing-remitting secondary progressive forms. In traumatic brain injury, longitudinal T1 changes strongly correlated with clinical recovery, surpassing T2 values. Conclusions The systematic review highlighted MRD as a groundbreaking technique that enhances neurological diagnosis by simultaneously quantifying T1 and T2 relaxation times. With reduced acquisition times, MRF outperforms conventional MRI in detecting subtle pathologies, distinguishing properties, and providing reliable biomarkers.

26 June 2024 in F1000Research
Verified
Journal Article
Open access
PDF file
Obhuli Chandran MadhivananObhuli Chandran Madhivanan
Obhuli Chandran Madhivanan
SPSaikiran Pendem
Saikiran Pendem
PSPriya Pattath Sankaran
Priya Pattath Sankaran
CCCijo Chacko
Cijo Chacko
RKRajagopal Kadavigere
Rajagopal Kadavigere
Background Non-contrast Computed Tomography (NCCT) plays a pivotal role in assessing central nervous system disorders and is a crucial diagnostic method. Iterative reconstruction (IR) methods have enhanced image quality (IQ) but may result in a blotchy appearance and decreased resolution for subtle contrasts. The deep-learning image reconstruction (DLIR) algorithm, which integrates a convolutional neural network (CNN) into the reconstruction process, generates high-quality images with minimal noise. Hence, the objective of this study was to assess the IQ of the Precise Image (DLIR) and the IR technique (iDose 4 ) for the NCCT brain. Methods This is a prospective study. Thirty patients who underwent NCCT brain were included. The images were reconstructed using DLIR-standard and iDose 4 . Qualitative IQ analysis parameters, such as overall image quality (OQ), subjective image noise (SIN), and artifacts, were measured. Quantitative IQ analysis parameters such as Computed Tomography (CT) attenuation (HU), image noise (IN), posterior fossa index (PFI), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in the basal ganglia (BG) and centrum-semiovale (CSO) were measured. Paired t-tests were performed for qualitative and quantitative IQ analyses between the iDose 4 and DLIR-standard. Kappa statistics were used to assess inter-observer agreement for qualitative analysis. Results Quantitative IQ analysis showed significant differences (p<0.05) in IN, SNR, and CNR between the iDose 4 and DLIR-standard at the BG and CSO levels. IN was reduced (41.8-47.6%), SNR (65-82%), and CNR (68-78.8%) were increased with DLIR-standard. PFI was reduced (27.08%) the DLIR-standard. Qualitative IQ analysis showed significant differences (p<0.05) in OQ, SIN, and artifacts between the DLIR standard and iDose 4 . The DLIR standard showed higher qualitative IQ scores than the iDose 4 . Conclusion DLIR standard yielded superior quantitative and qualitative IQ compared to the IR technique (iDose4). The DLIR-standard significantly reduced the IN and artifacts compared to iDose 4 in the NCCT brain.