Paweł Suchorab

Dr. Paweł Suchorab

Faculty of Environmental Engineering and Energy, Lublin University of Technology, Lublin, Lubelskie, Poland
orcid
Smart water supply enthusiast

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2022 in Applied Water Science
Verified
Journal Article
Open access
PDF file
BKBeata Kowalska
Beata Kowalska
Paweł SuchorabPaweł Suchorab
Paweł Suchorab
Dariusz KowalskiDariusz Kowalski
Dariusz Kowalski
Designing of District metered areas (DMA) schemes is a key element in developing a technique for detecting and removing unreported leaks in a water distribution system (WDS) called active leakage control. The design of DMA is very specific to individual networks’ hydraulic and often constitutes one area with pressure managed zones. This paper presents the division of a selected water supply network zone into DMA areas. Based on the spatial distribution of the flow rate and the geometrical structure of the network (routes, pipe diameters, existing gate valves) in the analyzed water supply zone, the main transmission trunks were separated (DN150 ÷ DN500 diameter range) and were excluded from the division into metering areas. DMA areas were separated from the remaining parts of the network, using the district metered areas module, supporting the division of water supply networks into metering zones, available in the WaterGEMS software by Bentley. The number of nodes in the area was 200 as the main criterion for separating DMAs. The separated areas were combined into 3 main DMA zones, in which the sum of the pipe lengths varied between 2500 ÷ 3800 m. For each of the DMAs, the water supply route was determined individually, seeking a one-sided inflow to the isolated area. In two out of three cases, this goal has been achieved. In the third case, it turned out necessary to provide two-sided water inflow. The analysis of the correct operation of DMAs was based on the hydraulic modeling of WDS.

7 March 2019 in Water
Verified
Journal Article
Open access
PDF file
Dariusz KowalskiDariusz Kowalski
Dariusz Kowalski
BKBeata Kowalska
Beata Kowalska
TBTomasz Bławucki
Tomasz Bławucki
Paweł SuchorabPaweł Suchorab
Paweł Suchorab
Krzysztof GaskaKrzysztof Gaska
Krzysztof Gaska
The process of shaping distribution network structures is one of the most fundamental design tasks, and determines the delivery certainty of media transported by them. It is especially crucial with reference to network elements of a critical character, such as roads or water supply, sewage, or electrical networks. In urban conditions, the geometric shaping of these structures has a quasi-chaotic character that is individual for each network and city. The complexity of these networks increases significantly with the size of a city, and therefore the evaluation of water delivery certainty is also a difficult issue. Despite many years of research, there is no universal method to evaluate this certainty. The objective of this paper is to present two original approaches: the number of minimal efficiency paths from a water source to reference consumption nodes, and the relation of this number to the fractal dimension of a network’s geometric structure. The developed methods were tested in the conditions of a few real water supply networks. The obtained results indicate that the analyzed methods can be used for the preliminary and relatively rapid evaluation of water delivery certainty.

15 December 2017 in ITM Web of Conferences
Verified
Journal Article
Open access
KŚKarolina Świtnicka
Karolina Świtnicka
Paweł SuchorabPaweł Suchorab
Paweł Suchorab
BKBeata Kowalska
Beata Kowalska
The proper maintenance of water distribution systems (WDSs) requires from operators multiple actions in order to ensure optimal functioning. Usually, all requirements should be adjusted simultaneously. Therefore, the decision-making process is often supported by multi-criteria optimisation methods. Significant improvements of exploitation conditions of WDSs functioning can be achieved by connecting small water supply networks into group systems. Among many potential tools supporting advanced maintenance and management of WDSs, significant improvements have tools that can find the optimal solution by the implemented mechanism of metaheuristic methods, such as the genetic algorithm. In this paper, an exemplary WDS functioning optimisation is presented, in relevance to a group water supply system. The action range of optimised parameters included: maximisation of water flow velocity, regulation of pressure head, minimisation of water retention time in a network (water age) and minimisation of pump energy consumption. All simulations were performed in Bentley WaterGEMS software.

6 March 2017 in Periodica Polytechnica Civil Engineering
Verified
Journal Article
Closed access
Małgorzata IwanekMałgorzata Iwanek
Małgorzata Iwanek
Paweł SuchorabPaweł Suchorab
Paweł Suchorab
MKMałgorzata Karpińska-Kiełbasa
Małgorzata Karpińska-Kiełbasa
The result of a breakage of a buried water pipe is the watermovement in soil, which can cause that fine soil particles arewashed out from the solid matrix and transported through pores(suffosion process). It is widely known that the most hazardoussuffosion effects in urban areas relate to water-engineeringstructures. Holes, that can form on the soil surface by wateroutflowing after a failure of a buried pipeline (suffosion holes),are in different shapes and sizes. Recognition of factors influencingholes shapes and sizes would facilitate the preventionof hazardous suffosion effects connected with failures of waterdistribution systems. In the range of the presented article, theinfluence of selected parameters on the dimensions of suffosionholes was analyzed. The basis of the analysis was results oflaboratory investigations of the controlled leakage from a buriedwater pipe. The vast majority of values of suffosion holesareas, selected according to area of leak and hydraulic pressurehead in a pipe, occurred normally distributed. The tendencyof average area of suffosion holes to be higher with risingpressure head in a pipe was clearly visible, but we were asyet unable to select one regression model fitting measured andcalculated data better than others. Moreover, no tendency wasobserved between the biggest probable area of suffosion holeand pressure head in a pipe.

28 January 2021 in Applied Water Science
Verified
Journal Article
Open access
PDF file
Paweł SuchorabPaweł Suchorab
Paweł Suchorab
Małgorzata IwanekMałgorzata Iwanek
Małgorzata Iwanek
Agnieszka ŻelaznaAgnieszka Żelazna
Agnieszka Żelazna
The most important goal of every water distribution system is to deliver water to the consumers in the demand and time determined by its users. However, not all water usages require the potable water quality. One of the technical solutions enabling water recycling and its reuse is a dual installation system. Dual installations recycle rain wastewater or grey water from bathtubs, showers and sinks and further reuse it for irrigation or toilet flushing. The profitability of a dual installation system is highly dependent on the water price, which tends to vary significantly according to the location. The purpose of this paper is to evaluate the profitability of dual installation systems in exemplary hotel building hypothetically located in 10 different European countries. The profitability was determined on the basis of multi-criteria decision analysis performed for two installation variants. The investment was evaluated in terms of technical, economic and environmental aspects. As a result, the selected countries were ranked in order of the most profitable location for dual installation system’s investment.

1 August 2020 in Journal of Ecological Engineering
Verified
Journal Article
Open access
Małgorzata IwanekMałgorzata Iwanek
Małgorzata Iwanek
Dariusz KowalskiDariusz Kowalski
Dariusz Kowalski
BKBeata Kowalska
Beata Kowalska
Paweł SuchorabPaweł Suchorab
Paweł Suchorab
Fractals are self-similar sets that can not be easily described by classical geometry. Fractals sets have been implemented in almost all areas of human activity since they were introduced to science by Mandelbrot in 1982. For the last 10 years, an interest in fractal geometry has increased by...