Petr Mánek

Dr. Petr Mánek

Institute of Experimental and Applied Physics, Czech Technical University in Prague, Prague, Praha, Hlavní Město, Czech Republic
+1
orcid
High-performance computing researcher in Physics

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2024 in Journal of Instrumentation
Verified
Journal Article
Open access
Petr MánekPetr Mánek
Petr Mánek
PBPetr Burian
Petr Burian
EDE. David-Bosne
E. David-Bosne
PSPetr Smolyanskiy
Petr Smolyanskiy
BBBenedikt Ludwig Bergmann
Benedikt Ludwig Bergmann
Fast, incremental evolution of physics instrumentation raises the question of efficient software abstraction and transferability of algorithms across similar technologies. This contribution aims to provide an answer by introducing Track Lab, a modern data acquisition program focusing on extensibility and high performance. Shipping with documented API and more than 20 standard modules, Track Lab allows complex analysis pipelines to be constructed from simple, reusable building blocks. Thanks to multi-threaded infrastructure, data can be clustered, filtered, aggregated and plotted concurrently in real-time. In addition, full hardware support for Timepix2, Timepix3 pixel detectors and embedded photomultiplier systems enables such analysis to be carried out online during data acquisition. Repetitive procedures can be automated with support for motorized stages and X-ray tubes. Freely distributed on 7 popular operating systems and 2 CPU architectures, Track Lab is a versatile tool for high energy physics research.

12 January 2023 in Machine Learning: Science and Technology
Verified
Journal Article
Open access
PDF file
Petr MánekPetr Mánek
Petr Mánek
GGGraham Van Goffrier
Graham Van Goffrier
VGVignesh Gopakumar
Vignesh Gopakumar
NNNikolaos Nikolaou
Nikolaos Nikolaou
JSJonathan Shimwell
Jonathan Shimwell
IWIngo Waldmann
Ingo Waldmann
The tritium breeding ratio (TBR) is an essential quantity for the design of modern and next-generation D-T fueled nuclear fusion reactors. Representing the ratio between tritium fuel generated in breeding blankets and fuel consumed during reactor runtime, the TBR depends on reactor geometry and material properties in a complex manner. In this work, we explored the training of surrogate models to produce a cheap but high-quality approximation for a Monte Carlo (MC) TBR model in use at the UK Atomic Energy Authority. We investigated possibilities for dimensional reduction of its feature space, reviewed 9 families of surrogate models for potential applicability, and performed hyperparameter optimization. Here we present the performance and scaling properties of these models, the fastest of which, an artificial neural network, demonstrated R 2 = 0.985 and a mean prediction time of 0.898   μ s , representing a relative speedup of 8 × 10 6 with respect to the expensive MC model. We further present a novel adaptive sampling algorithm, Quality-Adaptive Surrogate Sampling, capable of interfacing with any of the individually studied surrogates. Our preliminary testing on a toy TBR theory has demonstrated the efficacy of this algorithm for accelerating the surrogate modelling process.

1 February 2024 in Journal of Instrumentation
Verified
Journal Article
Open access
PSPetr Smolyanskiy
Petr Smolyanskiy
MBMichael Bacak
Michael Bacak
BBBenedikt Ludwig Bergmann
Benedikt Ludwig Bergmann
PBPavel Broulím
Pavel Broulím
PBPetr Burian
Petr Burian
SWS.A. Wender
S.A. Wender
We characterize a novel instrument designed for radiation field decomposition and particle trajectory reconstruction for application in harsh radiation environments. The device consists of two Timepix3 assemblies with 500 µm thick silicon sensors in a face-to-face geometry. These detectors are interleaved with a set of neutron converters: 6LiF for thermal neutrons, polyethylene (PE) for fast neutrons above 1 MeV, and PE with an additional aluminum recoil proton filter for neutrons above ∼4 MeV. Application of the coincidence and anticoincidence technique together with pattern recognition allows improved separation of charged and neutral particles, their discrimination against γ-rays and assessment of the overall directionality of the fast neutron field. The instrument's charged particle tracking and separation capabilities were studied at the Danish Center for Particle Therapy (DCPT), the Proton Synchrotron, and Super Proton Synchrotron with protons (50–240 MeV), pions (1–10 GeV/c and 180 GeV/c). After developing temporal and spatial coincidence assignment methodology, we determine the relative amount of coincident detections as a function of the impact angle, present the device's impact angle resolving power (both in coincidence and anticoicidence channels). The detector response to neutrons was studied at the Czech Metrology Institute (CMI), at n_ToF and the Los Alamos Neutron Science Center (LANSCE), covering the entire spectrum from thermal up to 600 MeV. The measured tracks were assigned to their corresponding neutron energy by application of the time of flight technique. We present the achieved neutron detection efficiency as a function of neutron kinetic energy and demonstrate how the ratio of events found below the different converters can be used to assess the hardness of the neutron spectrum. As an application, we determine the neutron content within a PMMA phantom just behind the Bragg-peak during clinical irradiation condition with protons of 160 MeV.

22 May 2018 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
Andre SopczakAndre Sopczak
Andre Sopczak
BABabar Ali
Babar Ali
JBJakub Begera
Jakub Begera
BBBenedikt Bergmann
Benedikt Bergmann
TBThomas Billoud
Thomas Billoud
ZSZdenek Svoboda
Zdenek Svoboda
A network of Timepix (TPX) devices installed in the ATLAS cavern measures the LHC luminosity as a standalone system. The data were recorded from 13 TeV protonproton collisions in 2016. Using two TPX devices, the number of hits created by particles passing the pixel matrices was counted. Absolute luminosity is determined with the van der Meer scan technique by separating the LHC proton beams and measuring the widths of the beams in low-intensity LHC proton-proton collisions. The exact determination of the activation background contributes to the overall precision of the TPX luminosity measurements. The activation background varies in time due to induced radioactivity at the different positions of the TPX devices in the ATLAS cavern. The activation at a given time depends on the history of the LHC operation. A detailed study of induced radioactivity has been performed to reduce the uncertainty on both the relative and absolute luminosity measurements.

4 March 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
SBSimeon Bash
Simeon Bash
JCJohn Cesar
John Cesar
GDGreg Deuerling
Greg Deuerling
TDThomas Dodwell
Thomas Dodwell
SGStefano Germani
Stefano Germani
NWNeil Wilcer
Neil Wilcer

1 June 2025 in Journal of Instrumentation
Verified
Journal Article
Open access
PBPetr Burian
Petr Burian
PBPavel Broulím
Pavel Broulím
BBBenedikt Ludwig Bergmann
Benedikt Ludwig Bergmann
MFMartin Farkaš
Martin Farkaš
MJM. Jára
M. Jára
Petr MánekPetr Mánek
Petr Mánek
This paper presents Katherine Generation 2 (Gen2), an advanced readout system designed for Timepix3 pixel detector. The new system addresses limitations of the original Katherine (Gen1) design, particularly in terms of data throughput and support for multi-detector configurations. Katherine Gen2 supports two sensor inputs via VHDCI connectors and provides two independent bias voltage sources up to ±1 kV. It includes both Gigabit Ethernet and USB 3.0 interfaces, offering flexibility for remote or local high-throughput applications. Data handling pipeline has been extended to support dynamic detector mapping, hardware decoding of pixel data, and timestamping of external triggers. Compatibility with multiple chipboard types, including single-chip, quad (2× 2), and specialized detector units, is maintained. Benchmark measurements demonstrate that the system achieves the maximum data rate supported by the Timepix3 chip in USB 3.0 mode. The device is supported by established software tools and is intended as a flexible platform for various experimental and detector development applications.