Paweł Szczygieł

Dr. Paweł Szczygieł

Faculty of Mechatronics and Mechanical Engineering, Kielce University of Technology, 25-314 Kielce, Poland
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Tomasz KoziorTomasz Kozior
Tomasz Kozior
JBJerzy Bochnia
Jerzy Bochnia
Damian GogolewskiDamian Gogolewski
Damian Gogolewski
Paweł ZmarzłyPaweł Zmarzły
Paweł Zmarzły
Mateusz RudnikMateusz Rudnik
Mateusz Rudnik
MMMateusz Musiałek
Mateusz Musiałek
This paper presents the metrological quality and mechanical properties of models in the form of hook holders manufactured from MED610 polymer material using PolyJet Matrix (PJM) technology. Measurements in the dimensional and shape analysis were made using the optical method with a microscope. The mechanical test was estimated by static tensile testing of the fabricated parts. A comprehensive approach to both the analysis of test results based on standardized samples and real hook models makes the presented results of great scientific and engineering value and creates the possibility of practical use in the medical industry, which has not been so comprehensively presented in the currently published research papers. Analyzing the results of measurements of the geometrical characteristics of the elements, it can be concluded that the PolyJet Matrix 3D printing technology has demonstrated a high level of precision in manufacturing the prototype parts. The static tensile test of samples, taking into account the printing directions, showed a high anisotropy of mechanical properties. The results of both strength and simulation tests indicate that it is necessary to assume a relatively high safety factor, the value of which depends on the direction of printing, which, in the case of such a responsible medical application, is very important.

1 February 2024 in 3D Printing and Additive Manufacturing
Verified
Journal Article
Closed access
JBJerzy Bochnia
Jerzy Bochnia
Tomasz KoziorTomasz Kozior
Tomasz Kozior
Wiktor SzotWiktor Szot
Wiktor Szot
Mateusz RudnikMateusz Rudnik
Mateusz Rudnik
Paweł ZmarzłyPaweł Zmarzły
Paweł Zmarzły
MMMateusz Musiałek
Mateusz Musiałek
In connection with the growing demand of the medical and medicine-related industry for materials exhibiting biocompatible properties used as part of three-dimensional (3D) printing additive technologies. The article presents research results concerning rheological and selected mechanical properties of a modern, photocurable MED610 resin, which is also used mainly in medicine, as well as dentistry. The article also shows extensive results of testing bending stress relaxation and creep, as well as the tensile strength of samples created with the PolyJet Matrix (PJM) technology. The authors used various sample types, including ones of unique shape and a hexagonal cellular structure. The analysis of the impact of element orientation on the working platform of the machine (3D printer) on the obtained test results (so-called printing direction—Pd) was also taken into account as a key technological parameter of the 3D printing process. Experimental rheological curves were matched with theoretical curves resulting from the application of a five-parameter Maxwell–Wiechert (M-W) model in the case of stress relaxation and a five-parameter Kelvin–Voigt model for creep. Very good matches were achieved, mean coefficients Chi 2 = 0.0014 and R 2 = 0.9956 for matching the five-parameter M-W model and mean coefficients Chi 2 = 0.000006 and R 2 = 0.9992 enable recommending the obtained results to be used for various engineering calculations, especially computer simulations. Moreover, the use of relaxation curves can significantly increase the construction capabilities within the design process, which includes the MED610 material.

20 March 2024 in Polimery
Verified
Journal Article
Open access
PDF file
NKNatalia Aleksandra Kowalska
Natalia Aleksandra Kowalska
Paweł SzczygiełPaweł Szczygieł
Paweł Szczygieł
MSMichal Skrzyniarz
Michal Skrzyniarz
SBSlawomir Blasiak
Slawomir Blasiak
Effect of shells number (1–5) on tensile properties of PLA samples printed using the FDM/FFF technique was investigated. The crack surface was also analyzed. The best properties were obtained for 4-shell sample. However, due to the large coefficient of variation (>> 10%) in the case of elongation, 3-shell sample was selected for testing the machining impact. Such a large coefficient of variation can be explained by the presence of voids between the layers. The greater the number of layers, the greater the structure defects. Machining increases surface smoothness while reducing tensile strength and practically unchanged elongation at break.

17 December 2025 in Materials
Verified
Journal Article
Open access
PDF file
Paweł SzczygiełPaweł Szczygieł
Paweł Szczygieł
KRKrystyna Joanna Radoń-Kobus
Krystyna Joanna Radoń-Kobus
This study presents results on a thermoplastic polymer composite containing 95 wt.% steel powder, processed into samples using Fused Deposition Modeling (FDM) technology. Such a high filler loading exceeds the values commonly reported in the literature. Samples were printed with different build orientations (0° and 90°) to evaluate the influence of printing direction on the tensile behavior of the material. Tensile tests were conducted to determine the effect of printing orientation on the composite’s strength. Additionally, surface structure analysis was performed using a contact profilometer, and wettability was evaluated by measuring the contact angle with a tensiometer. Dimensional measurements were also carried out using a digital caliper. The obtained results allowed determination of the relationship between printing orientation and the tensile and surface-related properties of the analyzed composite material.

30 December 2025 in Materials
Verified
Journal Article
Open access
PDF file
UKUrszula Kmiecik-Sołtysiak
Urszula Kmiecik-Sołtysiak
Paweł SzczygiełPaweł Szczygieł
Paweł Szczygieł
Dagmara Magdalena MichtaDagmara Magdalena Michta
Dagmara Magdalena Michta
KGKatarzyna Gałczyńska
Katarzyna Gałczyńska
This study evaluated the properties of two commercial filaments intended for medical and sterile applications: PLACTIVE (Copper 3D, Santiago, Chile) and CPE ANTIBAC (Fiberlogy, Brzezie, Poland). The aim of the research was to compare the dimensional accuracy, repeatability of the fused deposition modeling (FDM) 3D printing process, and the antibacterial properties of the samples using standardized procedures. Four types of samples were manufactured: geometrically differentiated specimens for metrological measurements (S1); cylinders with a diameter of 15 mm and a height of 40 mm for assessing process repeatability (S2); rectangular specimens measuring 40 × 40 × 2 mm for surface topography analysis (S3); and rectangular samples measuring 20 × 20 × 2 mm for biocidal property evaluation (S4). The results demonstrated that PLACTIVE samples exhibited higher dimensional conformity with nominal values and lower variability of diameters than CPE ANTIBAC samples, which may be associated with greater process stability. For both materials, the PSm parameter was correlated with layer height only in the 90° printing orientation. Surface topography analysis showed that increasing the layer height from 0.08 mm to 0.20 mm led to a significant rise in Rsm, Ra, and Sa values, indicating deterioration in the reproduction of micro-irregularities and increased spatial differentiation of the surface. For PLACTIVE samples, a tendency toward more convex structures with positive Rsk values and moderate kurtosis (Rku) was observed, suggesting uniform plasticization and stable interlayer bonding, particularly at the 0° orientation. In contrast, CPE ANTIBAC samples (especially those printed at 90°) were characterized by higher Ra and Sa values and negative skewness (Rsk), indicating valley-dominated, sharper surface morphology resulting from different rheological behavior and faster solidification of the material. PLACTIVE samples did not exhibit antibacterial properties against Escherichia coli (E. coli), while for Staphylococcus aureus (S. aureus), the activity was independent of printing direction and layer height. The CPE ANTIBAC material showed antibacterial effects against both tested strains in approximately 50% of the samples. The findings provide insights into the relationships between material type, printing orientation, and process parameters in shaping the dimensional and biocidal properties of FDM filaments.

19 September 2025 in Sensors
Verified
Journal Article
Open access
PDF file
ABAnna Bujarska
Anna Bujarska
Paweł ZmarzłyPaweł Zmarzły
Paweł Zmarzły
Paweł SzczygiełPaweł Szczygieł
Paweł Szczygieł
Fused Deposition Modeling (FDM), also known as Fused Filament Fabrication (FFF), is a widely used additive manufacturing (AM) method for thermoplastic materials due to its low cost, accessibility, and ability to produce fully functional machine parts. Cylindrical components, common in mechanical devices, require precise dimensional and form accuracy to ensure long service life. To assess their quality, cylindricity deviation measurements are essential, as they reveal defects generated during the printing process. This study investigates the potential of optical scanning for measuring form deviations specifically cylindricity and roundness of ABS components manufactured via FDM. The influence of printing orientation (0°, 45°, 90°) on dimensional accuracy was examined using experimental models comprising three series of ten samples each, with identical process parameters except orientation. Measurements were performed using a Zeiss Prismo Navigator (Zeiss, Oberkochen, Germany) coordinate measuring machine and an ATOS II Triple Scan (GOM, Brunswick, Germany) optical scanner. Results indicate that print orientation significantly affects cylindricity deviation. The lowest deviations were achieved for specific orientations, offering guidelines for producing cylindrical surfaces of acceptable quality. The findings also show that optical scanners are not suitable for precise form deviation analysis in FDM-printed parts, confirming the higher accuracy of tactile coordinate measurement methods.