Aims: Catheter ablation (CA) is an established treatment for atrial fibrillation (AF). A computed tomography (CT) may be performed before ablation to evaluate the anatomy of pulmonary veins. The aim of this study is to investigate the prevalence of patients with coronary artery disease (CAD) detected by cardiac CT scan pre-ablation and to evaluate the impact of CAD and revascularization on outcomes after AF ablation. Methods and results: All consecutive patients with AF diagnosis, hospitalized at Universitair Ziekenhuis Brussel, Belgium, between 2015 and 2019, were prospectively screened for enrolment in the study. Inclusion criteria were (i) AF diagnosis, (ii) first procedure of AF ablation with cryoballoon CA, and (iii) contrast CT scan performed pre-ablation. A total of 576 consecutive patients were prospectively included and analysed in this study. At CT scan, 122 patients (21.2%) were diagnosed with CAD, of whom 41 patients (7.1%) with critical CAD. At survival analysis, critical CAD at CT scan was a predictor of atrial tachyarrhythmia (AT) recurrence during the follow-up, only in Cox univariate analysis [hazard ratio (HR) = 1.79] but was not an independent predictor in Cox multivariate analysis. At Cox multivariate analysis, independent predictors of AT recurrence were as follows: persistent AF (HR = 2.93) and left atrium volume index (HR = 1.04). Conclusion: In patients undergoing CT scan before AF ablation, critical CAD was diagnosed in 7.1% of patients. Coronary artery disease and revascularization were not independent predictors of recurrence; thus, in this patient population, AF ablation should not be denied and can be performed together with CAD treatment.
1 September 2023 in Interdisciplinary CardioVascular and Thoracic Surgery
OBJECTIVES: Brugada syndrome is a life-threatening disease with an arrhythmogenic substrate located in the epicardium of right ventricle outflow tract. Therefore, the correct region identification is crucial for a successful ablation procedure. Various mapping techniques can be adopted to elaborate this issue, but they were all initially developed for endovascular use. METHODS: In this study, we analysed 21 consecutive hybrid video-assisted thoracoscopic ablation of Brugada syndrome, performed using different mapping systems to identify the ablation target and confirm the elimination of arrhythmogenic substrate; 35 maps have been analysed. RESULTS: Acute success of epicardial right ventricle outflow tract ablation has been achieved in 100% of procedures, no periprocedural complications have been observed; HD Grid catheter showed higher area identification speed and faster fractionated potentials visualization; Rhythmia system has demonstrated the best map density; Carto 3 system showed a significant advantage in patient preparation time, but mapping speed was reduced due to focal catheter use only. CONCLUSIONS: All tested electro anatomical mapping systems can be used for hybrid video-assisted thoracoscopic ablation with same clinical success; however, accuracy and efficacy of mapping systems are heterogenous and highly dependent on proper patient preparation, mapping system and physician skills.
Patient-tailored, 3D-printed surgical guides offer significant potential to improve precision and therapeutic efficacy in cardiac ablation surgery. However, reliable post-sterilization material performance presents a critical yet underexplored barrier to clinical adoption. This study investigates how disinfection and sterilization impact the mechanical and thermal properties of photopolymer resins. Specimens from two 3D-printing resins (Bioflex A80 MB™, 3Dresyns; MED625FLX™, Stratasys) were treated with four combinations of disinfection techniques (low-temperature manual cleaning; high-temperature machine washing) and sterilization techniques (H2O2 vs. autoclaving). We assessed post-sterilization properties by mechanical (material integrity, bending tests), thermal (differential scanning calorimetry, thermogravimetric analysis), and viscoelastic (dynamic mechanical analysis) studies. Statistical analysis was performed using one-way ANOVA with Bonferroni post hoc tests (α = 0.05). From this preliminary study, we conclude that MED625FLX maintains integrity and flexibility across all tested disinfection and sterilization methods. Bioflex A80 MB is only suitable for low-temperature disinfection–sterilization, as high-temperature treatments cause surface cracking. Neither resin is appropriate for cryogenic conditions due to the risk of brittleness. Further research into post-sterilization properties is essential to ensure the safety and clinical reliability of these materials in cardiac procedures.
To date, studies assessing the safety profile of 3D printing materials for application in cardiac ablation are sparse. Our aim is to evaluate the safety and feasibility of two biocompatible 3D printing materials, investigating their potential use for intra-procedural guides to navigate surgical cardiac arrhythmia ablation. Herein, we 3D printed various prototypes in varying thicknesses (0.8 mm–3 mm) using a resin (MED625FLX) and a thermoplastic polyurethane elastomer (TPU95A). Geometrical testing was performed to assess the material properties pre- and post-sterilization. Furthermore, we investigated the thermal propagation behavior beneath the 3D printing materials during cryo-energy and radiofrequency ablation using an in vitro wet-lab setup. Moreover, electron microscopy and Raman spectroscopy were performed on biological tissue that had been exposed to the 3D printing materials to assess microparticle release. Post-sterilization assessments revealed that MED625FLX at thicknesses of 1 mm, 2.5 mm, and 3 mm, along with TPU95A at 1 mm and 2.5 mm, maintained geometrical integrity. Thermal analysis revealed that material type, energy source, and their factorial combination with distance from the energy source significantly influenced the temperatures beneath the 3D-printed material. Electron microscopy revealed traces of nitrogen and sulfur underneath the MED625FLX prints (1 mm, 2.5 mm) after cryo-ablation exposure. The other samples were uncontaminated. While Raman spectroscopy did not detect material release, further research is warranted to better understand these findings for application in clinical settings.
Aims: A novel sinus node (SN) sparing hybrid ablation for inappropriate sinus node tachycardia (IST)/postural orthostatic tachycardia syndrome (POTS) has been demonstrated to be an effective and safe therapeutic option in patients with symptomatic drug-resistant IST/POTS. The aim of this study was to evaluate the long-term rate of redo procedures after hybrid IST ablation and procedural strategy, outcomes and safety of redo procedures. Methods and results: All consecutive patients from 2015 to 2023 were prospectively enrolled in the UZ Brussel monocentric IST/POTS registry. They were analysed if the following inclusion criteria were fulfilled: 1) diagnosis of IST or POTS, 2) symptomatic IST/POTS refractory or intolerant to drugs, and 3) hybrid SN sparing ablation performed. The primary endpoint was redo procedure. The primary safety endpoint was pacemaker (PM) implantation. A total of 220 patients undergone to hybrid IST ablation were included, 185 patients (84.1%) were treated for IST and 61 patients (27.7%) for POTS. After a follow-up of 73.3 ± 16.2 months, 34 patients (15.4%) underwent a redo. A total of 23 patients (67.6%) had a redo for IST recurrence and 11 patients (32.4%) for other arrhythmias. Pacemaker implantation was performed in 21 patients (9.5%). Nine patients (4.1%) had no redo procedure and experienced sick sinus syndrome requiring a PM. Twelve patients (5.4%) received a PM as a shared therapeutic choice combined with SN ablation procedure. Conclusion: In a large cohort of patients the long-term free survival from redo procedure after hybrid IST ablation was 84.6% with a low PM implantation rate.
Purpose The development of an atrio-esophageal fistula, a rare yet potentially lethal complication of ablation for atrial fibrillation, could be related to direct tissue heat transfer during and immediately after the ablation. We therefore studied the postoperative esophageal findings by esophagogastroduodenoscopy in patients that underwent a hybrid ablation procedure using a novel preventive strategy to avoid thermal lesions. Methods Thirty-four patients (28 males; 65 years ± 9 years) were retrospectively included. All underwent a hybrid ablation in our center between April 2015 and November 2019 and agreed to an esophagogastroduodenoscopy within 0–14 days (mean: 5 days) following the ablation. To reduce the incidence of thermal lesions three procedural preventive strategies were introduced: (i) videoscopic intrathoracic transesophageal echocardiographic probe visualization to understand the relationship between posterior left atrial wall and esophagus, with probe retraction before ablation; (ii) lifting the cardiac tissue away from the esophagus during energy application; and (iii) a 30-s cool-off period after energy delivery with irrigation of the device, the ablated tissue, and the surrounding tissues. Results No esophageal thermal lesions were observed. One third of patients were diagnosed with incidental esophageal findings unrelated to the ablation procedure (11; 32.4%). Conclusion Novel preventive strategies by visualization and by avoiding contact between the ablation catheter or ablated tissue and the pericardium, seems to eliminate the potential risk of esophageal thermal lesions in the setting of hybrid ablation. Since one third of patients had preexisting esophageal disease, a more comprehensive pre-operative screening could be important to reduce the risk.