Ivan Eltsov

Dr. Ivan Eltsov

Vrije Universiteit Brussel, Brussels, Brussels-Capital Region, Belgium
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
LPLuigi Pannone
Luigi Pannone
IDIoannis Doundoulakis
Ioannis Doundoulakis
MCMaría Cespón-Fernández
María Cespón-Fernández
IEIvan Eltsov
Ivan Eltsov
GCGian Battista Chierchia
Gian Battista Chierchia
ASAndrea Sarkozy
Andrea Sarkozy
The novel mapping and ablation lattice-tip catheter (Sphere-9; Medtronic, Minneapolis, MN, USA)1,2 can toggle between pulsed field (PF)3 and radiofrequency (RF) energy. In pre-clinical studies, it showed promising results for ventricular tissue treatment.4,5 However, there are no clinical studies reported for ventricular tachycardia (VT) ablation.6

Verified
Journal Article
Open access
PDF file
MMMassimiliano Marini
Massimiliano Marini
LPLuigi Pannone
Luigi Pannone
DRDomenico Giovanni. Della Rocca
Domenico Giovanni. Della Rocca
SBStefano Branzoli
Stefano Branzoli
ABAntonio Bisignani
Antonio Bisignani
FGFabrizio Guarracini
Fabrizio Guarracini
Electrical isolation of pulmonary veins (PVI) is the cornerstone of invasive treatment of atrial fibrillation (AF). However, arrhythmia-free survival of a PVI only approach is suboptimal in patients with persistent and long-term persistent AF. Hybrid AF ablation has been developed with the aim of combining the advantages of a thoracoscopic surgical ablation (direct visualization of anatomical structures to be spared and the possibility to perform epicardial lesions) and endocardial ablation (possibility to check line block, confirm PVI, and possibility to perform cavotricuspid isthmus ablation). Patient selection is of utmost importance. In persistent and long-term persistent AF, hybrid AF ablation demonstrated promising results in terms of AF free survival. It has been associated with a relatively low complication rate if performed in centers with expertise in hybrid procedures and experience with both surgical and endocardial ablation. Different techniques have been described, with different approaches and lesion sets. The aim of this review is to provide a state-of-the-art overview of hybrid AF ablation.

1 September 2023 in Interdisciplinary CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
IEIvan Eltsov
Ivan Eltsov
LPLuigi Pannone
Luigi Pannone
RRRobbert Ramak
Robbert Ramak
CMCinzia Monaco
Cinzia Monaco
DRDomenico Giovanni Della Rocca
Domenico Giovanni Della Rocca
MMMark La Meir
Mark La Meir
OBJECTIVES: Brugada syndrome is a life-threatening disease with an arrhythmogenic substrate located in the epicardium of right ventricle outflow tract. Therefore, the correct region identification is crucial for a successful ablation procedure. Various mapping techniques can be adopted to elaborate this issue, but they were all initially developed for endovascular use. METHODS: In this study, we analysed 21 consecutive hybrid video-assisted thoracoscopic ablation of Brugada syndrome, performed using different mapping systems to identify the ablation target and confirm the elimination of arrhythmogenic substrate; 35 maps have been analysed. RESULTS: Acute success of epicardial right ventricle outflow tract ablation has been achieved in 100% of procedures, no periprocedural complications have been observed; HD Grid catheter showed higher area identification speed and faster fractionated potentials visualization; Rhythmia system has demonstrated the best map density; Carto 3 system showed a significant advantage in patient preparation time, but mapping speed was reduced due to focal catheter use only. CONCLUSIONS: All tested electro anatomical mapping systems can be used for hybrid video-assisted thoracoscopic ablation with same clinical success; however, accuracy and efficacy of mapping systems are heterogenous and highly dependent on proper patient preparation, mapping system and physician skills.

1 December 2024 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
LPLuigi Pannone
Luigi Pannone
DRDomenico Giovanni. Della Rocca
Domenico Giovanni. Della Rocca
PVPasquale Vergara
Pasquale Vergara
ASAntonio Sorgente
Antonio Sorgente
AMAlvise Del Monte
Alvise Del Monte
Carlo de AsmundisCarlo de Asmundis
Carlo de Asmundis
BACKGROUND: Brugada syndrome (BrS) is associated with ventricular fibrillation (VF). Different VF mechanisms have been described, and repolarization gradients were associated with VF in a BrS model. The aim of this study is to map VF in BrS with ECG imaging. Furthermore, spatial correlation between sinus rhythm maps and VF maps was evaluated. METHODS: Inclusion criteria were (1) BrS diagnosis and (2) VF mapped with ECG imaging during right ventricle outflow tract ablation. VF mechanism was classified into (1) rotational, (2) focal, and (3) irregular. For comparison, 6 controls were enrolled. The following sinus rhythm maps were performed: activation, recovery time, and activation-recovery interval time. Spatial overlap between steep repolarization gradients (cliffs) at recovery time and activation-recovery interval time maps and initiating VF rotational activity was evaluated with photogrammetry. RESULTS: A total of 28 VF maps in 21 patients with BrS were analyzed. In the first ≈7 seconds of VF, rotational, focal, and irregular mechanisms were found. In 19 patients with BrS (90.5%) and none of the controls, a right ventricle outflow tract repolarization cliff only was found. In all these patients, the singularity point of the first initiating rotational VF activity spatially overlapped with the right ventricle outflow tract cliff. Abolition of right ventricle outflow tract repolarization cliffs was confirmed in all but 2 patients (94.3%). In one patient with recurrence, VF was mapped on the anterior right ventricle over a cliff that was not targeted at the first ablation procedure. CONCLUSIONS: In patients with BrS, repolarization heterogeneity has a critical role in VF. Repolarization cliffs might be a therapeutic target in VF ablation.

28 August 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
Rani L. KronenbergerRani L. Kronenberger
Rani L. Kronenberger
RKRawan Kazma
Rawan Kazma
AAALIREZA MAHDIAN AMIRABADI
ALIREZA MAHDIAN AMIRABADI
LULeire Viana Uribe
Leire Viana Uribe
GTGiacomo Talevi
Giacomo Talevi
Carlo de AsmundisCarlo de Asmundis
Carlo de Asmundis
Patient-tailored, 3D-printed surgical guides offer significant potential to improve precision and therapeutic efficacy in cardiac ablation surgery. However, reliable post-sterilization material performance presents a critical yet underexplored barrier to clinical adoption. This study investigates how disinfection and sterilization impact the mechanical and thermal properties of photopolymer resins. Specimens from two 3D-printing resins (Bioflex A80 MB™, 3Dresyns; MED625FLX™, Stratasys) were treated with four combinations of disinfection techniques (low-temperature manual cleaning; high-temperature machine washing) and sterilization techniques (H2O2 vs. autoclaving). We assessed post-sterilization properties by mechanical (material integrity, bending tests), thermal (differential scanning calorimetry, thermogravimetric analysis), and viscoelastic (dynamic mechanical analysis) studies. Statistical analysis was performed using one-way ANOVA with Bonferroni post hoc tests (α = 0.05). From this preliminary study, we conclude that MED625FLX maintains integrity and flexibility across all tested disinfection and sterilization methods. Bioflex A80 MB is only suitable for low-temperature disinfection–sterilization, as high-temperature treatments cause surface cracking. Neither resin is appropriate for cryogenic conditions due to the risk of brittleness. Further research into post-sterilization properties is essential to ensure the safety and clinical reliability of these materials in cardiac procedures.

28 February 2022 in Interactive CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
IEIvan Eltsov
Ivan Eltsov
ASAntonio Sorgente
Antonio Sorgente
Carlo de AsmundisCarlo de Asmundis
Carlo de Asmundis
MMMark La Meir
Mark La Meir
A 33-year-old woman with Sick Sinus Node syndrome and persistent atrial fibrillation underwent a Maze IV procedure in order treat atrial fibrillation and concomitant atrial epicardial implantation of a leadless pacemaker to manage her sinus node insufficiency. Last option has been chosen due to rare pocket complication after previous classic dual-chamber pacemaker implantation.