reduan abdullah

Mr. reduan abdullah

Hospital Universiti Sains Malaysia, Kota Bharu, Kelantan, Malaysia
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2019 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
NSNoor Nabilah Talik Sisin
Noor Nabilah Talik Sisin
KRKhairunisak Abdul Razak
Khairunisak Abdul Razak
SASafri Zainal Abidin
Safri Zainal Abidin
NMNor Fazila Che Mat
Nor Fazila Che Mat
RAreduan abdullah
reduan abdullah
WRWan Nordiana Rahman
Wan Nordiana Rahman
Purpose: The aim of this study was to investigate the potential of the synergetic triple therapeutic combination encompassing bismuth oxide nanoparticles (BiONPs), cisplatin (Cis), and high dose rate (HDR) brachytherapy with Ir-192 source in breast cancer and normal fibroblast cell line. Methods: In vitro models of breast cancer cell lines (MCF-7, MDA-MB-231) and normal fibroblast cell line (NIH/3T3) were employed. Cellular localization and cytotoxicity studies were conducted prior to inspection on the radiosensitization effects and generation of reactive oxygen species (ROS) on three proposed radiosensitizers: BiONPs, Cis, and BiONPs-Cis combination (BC). The optimal, non-cytotoxic concentration of BiONPs (0.5 mM) and the 25% inhibitory concentration of Cis (1.30 μM) were applied. The radiosensitization effects were evaluated by using a 0.38 MeV Iridium-192 HDR brachytherapy source over a prescribed dose range of 0 Gy to 4 Gy. Results: The cellular localization of BiONPs was visualized by light microscopy and accumulation of the BiONPs within the vicinity of the nuclear membrane was observed. Quantification of the sensitization enhancement ratio extrapolated from the survival curves indicates radiosensitization effects for MCF-7 and MDA-MB-231 when treated with BiONPs, Cis, and BC. However, NIH/3T3 cells exhibited contradictive behavior as it only reacted towards the BC combination. Nonetheless, the MCF-7 cell line loaded with BC shows the highest SER of 4.29. ROS production analysis, on the other hand, shows that Cis and BC radiosensitizers generated the highest free radicals in comparison to BiONPs alone. Conclusion: A BiONPs-Cis combination was unveiled as a novel approach that offers promising radiosensitization enhancement that will increase the efficiency of tumor control while preserving the normal tissue at a reduced dose. This data is the first precedent to prove the synergetic implication of BiONPs, Cis, and HDR brachytherapy that will be beneficial for future chemoradiotherapy strategies in cancer care.

1 October 2020 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
NSNoor Nabilah Talik Sisin
Noor Nabilah Talik Sisin
KRKhairunisak Abdul Razak
Khairunisak Abdul Razak
SASafri Zainal Abidin
Safri Zainal Abidin
NMNor Fazila Che Mat
Nor Fazila Che Mat
RAreduan abdullah
reduan abdullah
WRWan Nordiana Rahman
Wan Nordiana Rahman
Purpose: This study aimed to quantify synergetic effects induced by bismuth oxide nanoparticles (BiONPs), cisplatin (Cis) and baicalein-rich fraction (BRF) natural-based agent on the reactive oxygen species (ROS) generation and radiosensitization effects under irradiation of clinical radiotherapy beams of photon, electron and HDR-brachytherapy. The combined therapeutic responses of each compound and clinical radiotherapy beam were evaluated on breast cancer and normal fibroblast cell line. Methods: In this study, individual BiONPs, Cis, and BRF, as well as combinations of BiONPs-Cis (BC), BiONPs-BRF (BB) and BiONPs-Cis-BRF (BCB) were treated to the cells before irradiation using HDR brachytherapy with 0.38 MeV iridium-192 source, 6 MV photon beam and 6 MeV electron beam. The individual or synergetic effects from the application of the treatment components during the radiotherapy were elucidated by quantifying the ROS generation and radiosensitization effects on MCF-7 and MDA-MB-231 breast cancer cell lines as well as NIH/3T3 normal cell line. Results: The ROS generated in the presence of Cis stimulated the most substantial amount of ROS compared to the BiONPs and BRF. Meanwhile, the combination of the components had induced the higher ROS levels for photon beam than the brachytherapy and electron beam. The highest ROS enhancement relative to the control is attributable to the presence of BC combination in MDA-MB-231 cells, in comparison to the BB and BCB combinations. The radiosensitization effects which were quantified using the sensitization enhancement ratio (SER) indicate the highest value by BC in MCF-7 cells, followed by BCB and BB treatment. The radiosensitization effects are found to be more prominent for brachytherapy in comparison to photon and electron beam. Conclusion: The BiONPs, Cis and BRF are the potential radiosensitizers that could improve the efficiency of radiotherapy to eradicate the cancer cells. The combination of these potent radiosensitizers might produce multiple effects when applied in radiotherapy. The BC combination is found to have the highest SER, followed by the BCB combination. This study is also the first to investigate the effect of BRF in combination with BiONPs (BB) and BC (BCB) treatments.

2 March 2022 in Radiation
Verified
Journal Article
Open access
PDF file
NSNoor Nabilah Talik Sisin
Noor Nabilah Talik Sisin
RRRaizulnasuha Ab Rashid
Raizulnasuha Ab Rashid
RAreduan abdullah
reduan abdullah
KRKhairunisak Abdul Razak
Khairunisak Abdul Razak
MGMoshi Geso
Moshi Geso
WRWan Nordiana Rahman
Wan Nordiana Rahman
Interest in combining metallic nanoparticles, such as iron (SPIONs), gold (AuNPs) and bismuth oxide (BiONPs), with radiotherapy has increased due to the promising therapeutic advantages. While the underlying physical mechanisms of NP-enhanced radiotherapy have been extensively explored, only a few research works were motivated to quantify its contribution in an experimental dosimetry setting. This work aims to explore the feasibility of radiochromic films to measure the physical dose enhancement (DE) caused by the release of secondary electrons and photons during NP–radiotherapy interactions. A 10 mM each of SPIONs, AuNPs or BiONPs was loaded into zipper bags packed with GAFCHROMIC™ EBT3 films. The samples were exposed to a single radiation dose of 4.0 Gy with clinically relevant beams. Scanning was conducted using a flatbed scanner in red-component analysis for optimum sensitivity. Experimental dose enhancement factors (DEFExperimental) were then calculated using the ratio of absorbed doses (with/without NPs) converted from the films’ calibration curves. DEFExperimental for all NPs showed no significant physical DE beyond the uncertainty limits (p > 0.05). These results suggest that SPIONs, AuNPs and BiONPs might potentially enhance the dose in these clinical beams. However, changes in NPs concentration, as well as dosimeter sensitivity, are important to produce observable impact.

1 April 2022 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
AAAhmad Naqiuddin Azahari
Ahmad Naqiuddin Azahari
AGAhmad Tirmizi Ghani
Ahmad Tirmizi Ghani
RAreduan abdullah
reduan abdullah
JJJayapramila Jayamani
Jayapramila Jayamani
GAGokula Kumar Appalanaido
Gokula Kumar Appalanaido
MAMohd Zahri Abdul Aziz
Mohd Zahri Abdul Aziz

1 January 2016 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
MYM. F. Mohd Yusof
M. F. Mohd Yusof
RAreduan abdullah
reduan abdullah
ATA. A. Tajuddin
A. A. Tajuddin
RHR. Hashim
R. Hashim
BSBauk S.
Bauk S.
A set of tannin-based Rhizophora spp. particleboard phantoms with dimension of 30 cm x 30 cm was fabricated at target density of 1.0 g/cm3. The mass attenuation coefficient of the phantom was measured using 60Co gamma source. The phantoms were scanned using Computed Tomography (CT) scanner and the percentage depth dose (PDD) of the phantom was calculated using treatment planning system (TPS) at 6 MV and 10 MV x-ray and compared to that in solid water phantoms. The result showed that the mass attenuation coefficient of tannin-based Rhizohora spp. phantoms was near to the value of water with χ2 value of 1.2. The measured PDD also showed good agreement with solid water phantom at both 6 MV and 10 MV x-ray with percentage deviation below 8% at depth beyond the maximum dose, Z max .

1 January 2020 in Journal of Radiation Research and Applied Sciences
Verified
Journal Article
Open access
NNNorazlina Mat Nawi
Norazlina Mat Nawi
NANurul Syahirah Ahmad
Nurul Syahirah Ahmad
RAreduan abdullah
reduan abdullah
WZWan Mohd Nazlee Wan Zainon
Wan Mohd Nazlee Wan Zainon
MRMohammad Khairul Azhar Abdul Razab
Mohammad Khairul Azhar Abdul Razab
The efficacy of recombinant human thyroid stimulating hormone (rhTSH) and thyroid hormone withdrawal (THW) in estimating the whole body radioactive clearance was done by measuring the external dose rate for both stomach and neck at 1 m and 5 cm distances, respectively. Two groups of subjects, which were 34 patients with THW who stop the thyroxin uptake for 1 month and 3 patients with rhTSH injection at 24 and 48 h prior to radioiodine therapy, have been selected. Sequential dose rate at 1 m and 5 cm distances from stomach and neck was measured in these patients using a digital auto-ranging beta-gamma survey meter instrument for 0, 12, 24, 36 and 48 h after I-131 ingestion. The initial activities were ranged from 3700 to 5550 MBq. Significant statistical value of Mann Whitney Test (P < 0.05) at 24, 36 and 48 h proved the radioactive clearance of rhTSH injection was faster than patients with THW method, where the I-131 kinetics might be more effective in promoting the drug to the target tissues after 24 h. Patient with rhTSH injections could reduce the individual dose to organs and allowed to be discharged earlier than the patient with THW method.