Rodrigo García-Carmona

Dr. Rodrigo García-Carmona

Departamento de Ingeniería Telemática, Universidad Politécnica de Madrid, Madrid, Spain
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2018 in Journal of Proteome Research
Verified
Journal Article
Closed access
AGAlberto Gil-de-la-Fuente
Alberto Gil-de-la-Fuente
Joanna Barbara GodzienJoanna Barbara Godzien
Joanna Barbara Godzien
SSSergio Saugar
Sergio Saugar
Rodrigo García-CarmonaRodrigo García-Carmona
Rodrigo García-Carmona
HBHasan Badran
Hasan Badran
AOAbraham Otero
Abraham Otero

7 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
RRRafael Raya
Rafael Raya
Rodrigo García-CarmonaRodrigo García-Carmona
Rodrigo García-Carmona
CSCristina Sánchez
Cristina Sánchez
EJEloy Urendes Jiménez
Eloy Urendes Jiménez
OROscar Ramirez
Oscar Ramirez
AOAbraham Otero
Abraham Otero
Neck injuries and the related pain have a high prevalence and represent an important health problem. To properly diagnose and treat them, practitioners need an accurate system for measuring Cervical Range Of Motion (CROM). This article describes the development and validation of an inexpensive, small (4 cm × 4 cm × 8 cm), light (< 200 g) and easy to use solution for measuring CROM using wearable inertial sensors. The proposed solution has been designed with the clinical practice in mind, after consulting with practitioners. It is composed of: (a) two wearable wireless MEMS-based inertial devices, (b) a recording and report generation software application and (c) a measurement protocol for assessing CROM. The solution provides accurate (none of our results is outside the ROM ranges when compared with previously published results based on an optical tracking device) and reliable measurements (ICC = 0.93 for interrater reliability when compared with an optical tracking device and ICC > 0.90 for test-retest reliability), surpassing the popular CROM instrument’s capabilities and precision. It also fulfills the needs for clinical practice attending to effectiveness, efficiency (4 min from setup to final report) and user’s satisfaction (as reported by practitioners). The solution has been certified for mass-production and use in medical environments.

13 July 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Ana RojoAna Rojo
Ana Rojo
JSJose Angel Santos-Paz
Jose Angel Santos-Paz
ÁSÁlvaro Sánchez-Picot
Álvaro Sánchez-Picot
RRRafael Raya
Rafael Raya
Rodrigo García-CarmonaRodrigo García-Carmona
Rodrigo García-Carmona
Patients with upper limb disorders are limited in their activities of daily living and impose an important healthcare burden due to the repetitive rehabilitation they require. A way to reduce this burden is through home-based therapy using virtual reality solutions, since they are readily available, provide immersion, and enable accurate motion tracking, and custom applications can be developed for them. However, there is lack of guidelines for the design of effective VR rehabilitation applications in the literature, particularly for bimanual training. This work introduces a VR telerehabilitation system that uses off-the-shelf hardware, a real-time remote setup, and a bimanual training application that aims to improve upper extremity motor function. It is made of six activities and was evaluated by five physiotherapists specialised in (2) neuromotor disorders and (3) functional rehabilitation and occupational therapy. A descriptive analysis of the results obtained from the System Usability Scale test of the application and a collection of qualitative assessments of each game have been carried out. The application obtained a mean score of 86.25 (±8.96 SD) in the System Usability Scale, and the experts concluded that it accurately reproduces activities of daily living movements except for wrist and finger movements. They also offer a set of design guidelines.

28 May 2022 in Virtual Reality
Verified
Journal Article
Open access
PDF file
Ana RojoAna Rojo
Ana Rojo
JCJavier Cortina
Javier Cortina
CSCristina Sánchez
Cristina Sánchez
EJEloy Urendes Jiménez
Eloy Urendes Jiménez
Rodrigo García-CarmonaRodrigo García-Carmona
Rodrigo García-Carmona
RRRafael Raya
Rafael Raya
Virtual reality (VR) has emerged as a valid addition to conventional therapy in rehabilitation and sports medicine. This has enabled the development of novel and affordable rehabilitation strategies. However, before VR devices can be used in these situations, they must accurately capture the range of motion of the body-segment where they are mounted. This study aims to state the accuracy of the Oculus Touch v2 controller when used to measure the elbow’s motion in the sagittal plane. The controller is benchmarked against an inertial sensor (ENLAZA $$^{\mathrm{TM}}$$ TM ), which has already been validated as a reliable measurement device. We have developed a virtual environment that matches both the Oculus Touch v2 and the inertial sensor orientations using a digital goniometer. We have also collected the orientation measurements given by each system for a set of 17 static angles that cover the full range of normal elbow flexion and hyperextension motion, in 10° intervals from − 10° (hyperextension) to 150° (flexion). We have applied the intra-rater reliability test to assess the level of agreement between the measurements of these devices, obtaining a value of 0.999, with a 95% confidence interval ranged from 0.996 to 1.000. By analyzing the angle measurement outcomes, we have found that the accuracy degrades at flexion values between 70° and 110°, peaking at 90°. The accuracy of Oculus Touch v2 when used to capture the elbow’s flexion motion is good enough for the development of VR rehabilitation applications based on it. However, the flaws in the accuracy that have been revealed in this experimental study must be considered when designing such applications.

2 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
EJEloy Urendes Jiménez
Eloy Urendes Jiménez
GPGuillermo Asín Prieto
Guillermo Asín Prieto
RCRamón Ceres
Ramón Ceres
Rodrigo García-CarmonaRodrigo García-Carmona
Rodrigo García-Carmona
RRRafael Raya
Rafael Raya
JPJose L. Pons
Jose L. Pons
Robotic exoskeletons that induce leg movement have proven effective for lower body rehabilitation, but current solutions offer limited gait patterns, lack stabilization, and do not properly stimulate the proprioceptive and balance systems (since the patient remains in place). Partial body weight support (PBWS) systems unload part of the patient’s body weight during rehabilitation, improving the locomotive capabilities and minimizing the muscular effort. HYBRID is a complete system that combines a 6DoF lower body exoskeleton (H1) with a PBWS system (REMOVI) to produce a solution apt for clinical practice that offers improves on existing devices, moves with the patient, offers a gait cycle extracted from the kinematic analysis of healthy users, records the session data, and can easily transfer the patient from a wheelchair to standing position. This system was developed with input from therapists, and its response times have been measured to ensure it works swiftly and without a perceptible delay.

31 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
CSCristina Sánchez
Cristina Sánchez
VCVanina Costa
Vanina Costa
Rodrigo García-CarmonaRodrigo García-Carmona
Rodrigo García-Carmona
EJEloy Urendes Jiménez
Eloy Urendes Jiménez
Javier TejedorJavier Tejedor
Javier Tejedor
RRRafael Raya
Rafael Raya
This study evaluates and compares the suitability for child–computer interaction (CCI, the branch within human–computer interaction focused on interactive computer systems for children) of two devices: a standard computer mouse and the ENLAZA interface, a head mouse that measures the user’s head posture using an inertial sensor. A multidirectional pointing task was used to assess the motor performance and the users’ ability to learn such a task. The evaluation was based on the interpretation of the metrics derived from Fitts’ law. Ten children aged between 6 and 8 participated in this study. Participants performed a series of pre- and post-training tests for both input devices. After the experiments, data were analyzed and statistically compared. The results show that Fitts’ law can be used to detect changes in the learning process and assess the level of psychomotor development (by comparing the performance of adults and children). In addition, meaningful differences between the fine motor control (hand) and the gross motor control (head) were found by comparing the results of the interaction using the two devices. These findings suggest that Fitts’ law metrics offer a reliable and objective way of measuring the progress of physical training or therapy.