Purpose: Metal ion release may cause local and systemic effects and induce hypersensitivity reactions. The aim of our study is first to determine if implant-related hypersensitivity correlates to patient symptoms or not; second, to assess the rate of hypersensitivity and allergies in shoulder arthroplasty. Methods: Forty patients with shoulder replacements performed between 2015 and 2017 were studied with minimum 2-year follow-up; no patient had prior metal implants. Each patient underwent radiographic and clinical evaluation using the Constant-Murley Score (CMS), 22 metal and cement haptens patch testing, serum and urine tests to evaluate 12 metals concentration, and a personal occupational medicine interview. Results: At follow-up (average 45 ± 10.7 months), the mean CMS was 76 ± 15.9; no clinical complications or radiographic signs of loosening were detected; two nickel sulfate (5%), 1 benzoyl peroxide (2.5%) and 1 potassium dichromate (2.5%) positive findings were found, but all these patients were asymptomatic. There was an increase in serum aluminum, urinary aluminum and urinary chromium levels of 1.74, 3.40 and 1.83 times the baseline, respectively. No significant difference in metal ion concentrations were found when patients were stratified according to gender, date of surgery, type of surgery, and type of implant. Conclusions: Shoulder arthroplasty is a source of metal ion release and might act as a sensitizing exposure. However, patch test positivity does not seem to correlate to hypersensitivity cutaneous manifestations or poor clinical results. Laboratory data showed small constant ion release over time, regardless of gender, type of shoulder replacement and implant used. Levels of evidence: Level II.
Several bone grafts are available for clinical use, each with their own peculiar biological and mechanical properties. A new bone graft was obtained by combining mineral structures from natural bovine bones with bioresorbable polymers and cellular nutrients. The study aims to evaluate the clinical, biological and structural properties of this bone graft and its reliability in orthopedic oncology. 23 adult patients (age range 18–85 years) were treated between October 2016 and December 2018; the oncologicdiagnoses were heterogeneous. After surgical curettage and bone grafting, a clinical-radiological follow up was conducted. Radiographs were used to evaluate graft integration according to the usual bone healing and oncologic follow up. Local complications (infection, local recurrence, wound dehiscence, fracture or early reabsorption) were evaluated. The mean followup was of 18.34 ± 4.83 months. No fracture or infection occurred. One case of patellar Giant Cell Tumor (GCT) and one of proximal tibia low-grade chondrosarcoma recurred after about one year. Two wound dehiscences occurred (one required a local flap). Follow-up X-rays showed good to excellent graft integration in most patients (20 out of 21). The investigated graft has a mechanical and structural function that can allow early weight-bearing and avoid a preventive bone fixation (only needed in four patients in this series). The graft blocks are different for shapes and dimensions, but they can be customized by the producer or sawcut by the surgeon in the operating theatre to fit the residual bone cavity. The complication rate was low, and a rapid integration was observed with no inflammatory reaction in the surrounding tissues. Further studies are mandatory to confirm these promising results.
Introduction. Metastatic bone disease represents a systemic pathology that heavily affects the quality of life of oncologic patients causing pain and functional disability. Methodology. We present the case of a patient with a history of renal cell cancer presenting pathologic fractures of both humeri and proximal right radius. Results. After a careful multidisciplinary approach, an adjuvant anticancer therapy and a photodynamic bone stabilization procedure were performed with a minimally invasive technique aiming to minimize pain and local disease progression, while restoring functional autonomy and improving the patient’s quality of life. Electrochemotherapy was delivered on the lytic bone lesions with extraskeletal involvement of the proximal left humerus and the proximal right radius, and then polymeric bone stabilization was performed on both humeri. At two months of follow-up, the patient presented satisfactory functional scores (MSTS score: 12/30 bilaterally; DASH scores: 46.7/100 for the right side and 48.3/100 for the left one), and pain was well controlled with opioid analgesics. Radiographs showed good results in terms of ossification of lytic bone lesions and durability of polymeric stabilization. At four months of follow-up, the patient reported a stable clinical scenario. Six months after surgery, due to extremely poor prognosis after the progression of primary disease, the patient was referred to palliative care and died shortly thereafter. Conclusion. Over the last decade, the management of metastatic bone disease has changed. Low-toxicity and minimally invasive procedures such as electrochemotherapy and polymeric bone stabilization might be performed concomitantly in selected patients, as an alternative to radiation therapy and to more demanding surgical procedures such as plating and adjuvant cementing.
Case: A 35-year-old man with a giant cell tumor involving the lateral condyle and trochlea of the right distal femur underwent curettage of the lesion and cement grafting, which resulted in symptomatic patellofemoral osteoarthritis after more than 4 years. A standard follow-up excluded recurrence, whereas infection was ruled out while investigating the symptoms. Finally, a patellofemoral resurfacing prosthesis was implanted while filling the bone defects with tantalum cones.Conclusion: A “tailored” surgical technique with a selected patellofemoral joint arthroplasty could be used in oncologic setting to save further bone stock for possible revisions while permitting full and quick clinical recovery.