Léo Friedrich

Dr. Léo Friedrich

Eindhoven University of Technology
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Léo FriedrichLéo Friedrich
Léo Friedrich
MCMitrofan Curti
Mitrofan Curti
BGBart L. J. Gysen
Bart L. J. Gysen
Elena LomonovaElena Lomonova
Elena Lomonova
This paper presents a comparison between two high-order modeling methods for solving magnetostatic problems under magnetic saturation, focused on the extraction of machine parameters. Two formulations are compared, the first is based on the Newton-Raphson approach, and the second successively iterates the local remanent magnetization and the incremental reluctivity of the nonlinear soft-magnetic material. The latter approach is more robust than the Newton-Raphson method, and uncovers useful properties for the fast and accurate calculation of incremental inductance. A novel estimate for the incremental inductance relying on a single additional computation is proposed to avoid multiple nonlinear simulations which are traditionally operated with finite difference linearization or spline interpolation techniques. Fast convergence and high accuracy of the presented methods are demonstrated for the force calculation, which demonstrates their applicability for the design and analysis of electromagnetic devices.

31 May 2017 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
Léo FriedrichLéo Friedrich
Léo Friedrich
JPJohannes J. H. Paulides
Johannes J. H. Paulides
ELElena A. Lomonova
Elena A. Lomonova
The modeling and optimization of a direct-drive contactless tubular linear generator is investigated to ensure a highly reliable device with long lifetime for vibration energy harvesting application. A slotless structure is considered to minimize force ripples and simplify later control. A semi-analytical model based on harmonic Fourier modeling is considered for the calculation of the magnetic field generated by the permanent magnets. Electrical and thermal iterative models are coupled to the magnetic Fourier model into a general optimization tool both fast and accurate, which is validated by means of a finite element model.

7 August 2020 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
DDDoga Doǧa
Doga Doǧa
Léo FriedrichLéo Friedrich
Léo Friedrich
KBK. O. Boynov
K. O. Boynov
ELE. A. Lomonova
E. A. Lomonova
This paper presents a method for the computation of the incremental inductances in a 12/10 variable flux reluctance machine using the hybrid analytical modeling coupled with a fixed-point nonlinear solver. The variation of incremental and apparent inductance with respect to the dc-field excitation is investigated for both zero and non-zero ac-field excitations. The results show that the difference between both inductance values is not negligible after 25 A/mm2 dc-current density for the investigated benchmark without the ac field. Moreover, when a non-zero ac field is introduced in addition to the dc-field, the apparent inductance becomes misleading not only under magnetic saturation but also under low excitation in the linear region of the saturation curve. The results obtained with the proposed nonlinear hybrid model are compared with the finite element method in terms of magnetic flux density distribution and incremental inductance value. The root-mean-square discrepancy of magnetic flux density distribution is found to be 37.6 mT. Furthermore, the discrepancy between incremental inductance results of the proposed method and the finite element model is calculated as 1.43%, while the proposed approach requires less post-processing and necessitates ten times less number of degrees-of-freedom.

14 January 2020 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
Léo FriedrichLéo Friedrich
Léo Friedrich
BGB. L. J. Gysen
B. L. J. Gysen
JJJ.W. Jansen
J.W. Jansen
ELE. A. Lomonova
E. A. Lomonova

21 September 2020 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
DDDoga Doǧa
Doga Doǧa
Léo FriedrichLéo Friedrich
Léo Friedrich
KBKonstantin O. Boynov
Konstantin O. Boynov
ELElena A. Lomonova
Elena A. Lomonova
This article presents the convergence analysis of the fixed-point method (FPM) to model the nonlinear magnetic characteristics of a 2-D magnetostatic problem. In this study, FPM is used as the iterative nonlinear solver of the hybrid analytical modeling (HAM) technique for the accurate computation of the magnetic field distribution. The benchmark consists of a stator with excitation windings, an air gap, and a slotless mover. The relative errors between two successive iterations are calculated using different error estimators: the attraction force on the mover, the Fourier coefficients defined in the air gap, the magnetic flux density, and the magnetic scalar potential distributions. The effect of the number of mesh elements and harmonics on the accuracy and computational cost of the model is investigated for different levels of magnetic saturation. It is observed that the maximum rate of change in the relative difference of attraction force during the iterations is found to be 0.52 under the magnetic saturation. In addition, the absolute error of the attraction force between the developed hybrid model with FPM and the finite element method (FEM) is achieved to be 0.18%, while HAM has approximately three times less number of degrees-of-freedom when compared to FEM.

1 April 2018
Verified
Conference Paper
Closed access
Léo FriedrichLéo Friedrich
Léo Friedrich
Koen BastiaensKoen Bastiaens
Koen Bastiaens
BGB. L. J. Gysen
B. L. J. Gysen
DKD. C. J. Krop
D. C. J. Krop
ELE. A. Lomonova
E. A. Lomonova
This paper concerns the design optimization of two axial-flux permanent magnet (AFPM) machines, aimed to be used as a direct drive in-wheel motor for the propulsion of a solar-powered electric vehicle. The internal stator twin external rotor AFPM machine topology having either a distributed or toroidal stator winding configuration is investigated. The objective of the design optimization is to minimize the total volume of the machine. A gradient-based optimization algorithm is employed on a non-linear 2D equivalent motor model. The motor model consists of coupled electromagnetic and thermal models based on an Isogeometric Analysis (IGA) approach. A wide range of pole-pair numbers are optimized and compared in terms of power density and efficiency. Finally, the radius to evaluate the 2D model as a function of the pole-pair number is given, which minimizes the discrepancy with respect to the 3D finite element method (FEM).